Take out the power adapter from the packing box and
connect the ionizing air blower.
Place the ionizing air blower close to the working area
(about 300~750mm away from the
object with
electrostatic
to be eliminated), and the air outlet of
the ionizing air blower must be vertically aligned
with the object to be eliminated
.
Use screws or bolts to fix on a firm and flat surface(such
as a wall or shelf). The angle of ionizing air blower can
be adjusted by the knobs on both sides of the bracket to
achieve the best static elimination effect.
1
2
Step of use
1. Place the ionizing air blower in the working area where static electricity is to be eliminated. And the installation angle should be perpendicular to
the surface of the charged body and about 300 to 750 mm away from the static electricity object.
2.
Ionizing air blower should be at least 30cm away from the metal conductor and metal grounding body
.
3.
Two ionizing air blowers should be installed side by side with an interval of more than 400mm and more than 200mm away from obstacles
such
as walls.
4. The air inlet is at least 150mm away from the wall.
Installation position
Packing accessories
Wall
≥ 150mm
Wall
Wall
≥ 200mm
≥ 200mm
≥ 400mm
300~750mm
300~750mm
Switching power adapter
(national standard plug)
AP4705000
DSS28-1502000-A 100-240V 1.0A 50/60HZ DC15V-2.0A
wire length 2m