1.

Select the best static discharge position and install the bar body and the supporting power supply firmly.

2.

Insert the high-voltage plug of the bar body into the high-voltage output connecting seat of the supporting high-voltage power supply.

3.

Connect the grounding terminal of the bar body to the grounding stud of the high voltage power supply.

4.

Connect the air source connector on bar body(air source type) to the air source generating device and turn on the air source switch. (The
compressed air source must be equipped with a filter to ensure that the air is dry and clean to avoid the moisture, grease in the flow
affecting the insulation performance of the ion bar. )

5.

Turn on the power switch and indicator light on shows the power work. Adjust the proper air source pressure(air pressure ≤ 0.6MPa) to
generate positive and negative ions at the electrode needles to neutralize the surface static electricity of the object.

1

Do not disassemble the equipment.

2

Do not short-circuit the high-voltage power cable to avoid permanent damage to the power supply.

3

Please check the product power cable regularly, and replace it immediately if it is damaged, otherwise it is easy to cause problems such as 

electric leakage and abnormal work.
4

The power supply should be stored in a cool and dry environment.

5

Stop using immediately and send the power supply to Anping Company for processing if abnormalities or problems are found during use.

NO

Problems

Reasons

Solutions

Remark

1

The discharge electrode 

ignites the ground electrode 

on the side of the bar body

Dust accumulation on bar 

body causes a decrease in the 

surface insulation resistance

The carbon deposits on the 

discharge electrode and bar 

body should be cleaned and 

maintained regularly with 

electrostatic brush, dust-free 

cotton swab, dust-free cloth 

dipped in anhydrous alcohol 

according to the use 

environment and the required 

electrostatic protection 

requirements in order to 

ensure the good performance 

of the product

2

The discharge electrode 

ignites other metal 

grounding bodies

The bar body is installed 

too close to other metal 

grounding bodies

Power off  and clean bar body 

Move the installation position of the bar 

body and keep it more than 50mm away 

from other metal grounding bodies to 

ensure safe use and discharge performance

3

The electrostatic 

removal performance 

is   obviously reduced

Discharge needle is 

polluted and damaged

Clean or replace the ion bar

Bearing set of ion bar 

is improper

Confirm the best bearing set

4

The electrostatic 

removal performance 

is reduced

There are conductors or 

other ion bars around 

Remove conductors or other ion bars

5

Unable to discharge

High-voltage connecting 

wire is damaged

Return to factory for maintenance

Ion bar insulation is damaged

Return to factory for maintenance

Poor grounding/no grounding

Check the electrical grounding of ion 

bar and plant equipment

6

Product burnout

Ion bar insulation is damaged

Return to factory for maintenance

1.

AP-ABAP-AB1602A explosion-proof ion bar has undergone rigorous testing and aging treatment before ex-work. Its

 

performance 

has completely reached the relevant indicators marked in the usage instruction.

2.

AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge 

within one year from the date of purchase. However, this commitment does not apply to:

(1)

 The device is incorrectly used or installed.

(2)

 Damage caused by negligence or accident during use.

(3)

 Modified, disassembled or repaired by other service departments not authorized by Anping Company.

3.

AP&T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.

Содержание AP-AB1602A

Страница 1: ...Explosion proof Ion Bar Series AP AB1602A Explosion proof Ion Bar Series AP TR Shanghai Anping Static Technology Co Ltd AP T...

Страница 2: ...and other industries with flammable working conditions Effectively solve the problems caused by static electricity Static Removal Prevent uneven scattering Control ink splashing Prevent adhesion of ob...

Страница 3: ...nd explosive working places corresponding to B or lower level with this safe explosion proof function Can be used safely in flammable and explosive environments Explosion proof certificate No GYB21 33...

Страница 4: ...150 0 150 600 550 500 450 400 350 300 33 6 37 2 40 7 44 3 47 8 51 4 55 0 58 5 62 1 65 6 69 2 Z mm Y mm 150 150 Discharge ability Working way High Efficiency Static Removal Keep a clean production env...

Страница 5: ...182 1 500 150 0 2 6 783 6 225 36 7 28 85 94 4 0 2 785 2 487 3 4 52 35 101 3 150 5 16 4 349 31 3 37 15 105 6 150 0 4 3 295 3 46 28 1 69 15 110 2 0 1 683 1 408 13 9 66 4 118 9 150 3 213 2 911 1 7 56 1...

Страница 6: ...able to left or right and can be easily installed in different environments CE certification It can effectively avoid external electromagnetic interference affecting the normal operation of the ion ba...

Страница 7: ...0mm 600mm Installation distance 100 600mm Air pressure 0 6MPa Compressed air connector 8 G1 8 white Ion balance 50V Discharge speed 2 5S Test data may vary with test conditions Working temperature 0 5...

Страница 8: ...bolt M5 20 Shielded high voltage wire Air source connector with throttle Product size Product details Sliding mounting bolt M5 20 Discharge electrode Stomata Ground terminal High voltage plug Shielde...

Страница 9: ...om contaminating electrode needles causing high voltage insulation failure which affects normal use Installation distance Discharged object 300mm 300mm Step of use Installation position Galvanized Hex...

Страница 10: ...nstallation use and maintenance of the product should also abide by the product manual and the requirements of the following related standards and specifications GB 3836 13 2013 Explosive environment...

Страница 11: ...d and maintained regularly with electrostatic brush dust free cotton swab dust free cloth dipped in anhydrous alcohol according to the use environment and the required electrostatic protection require...

Страница 12: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...

Отзывы: