Operation guide
Trouble shooting
Maintenance
After-sales service
1.
Select the best static discharge position and install the bar body and the supporting power supply firmly.
2.
Insert the high-voltage plug of the bar body into the high-voltage output connecting seat of the supporting high-voltage power supply.
3.
Connect the grounding terminal of the bar body to the grounding stud of the high voltage power supply.
4.
Connect the air source connector on bar body(air source type) to the air source generating device and turn on the air source switch. (The
compressed air source must be equipped with a filter to ensure that the air is dry and clean to avoid the moisture, grease in the flow
affecting the insulation performance of the ion bar. )
5.
Turn on the power switch and indicator light on shows the power work. Adjust the proper air source pressure(air pressure ≤ 0.6MPa) to
generate positive and negative ions at the electrode needles to neutralize the surface static electricity of the object.
1
、
Do not disassemble the equipment.
2
、
Do not short-circuit the high-voltage power cable to avoid permanent damage to the power supply.
3
、
Please check the product power cable regularly, and replace it immediately if it is damaged, otherwise it is easy to cause problems such as
electric leakage and abnormal work.
4
、
The power supply should be stored in a cool and dry environment.
5
、
Stop using immediately and send the power supply to Anping Company for processing if abnormalities or problems are found during use.
NO
Problems
Reasons
Solutions
Remark
1
The discharge electrode
ignites the ground electrode
on the side of the bar body
Dust accumulation on bar
body causes a decrease in the
surface insulation resistance
The carbon deposits on the
discharge electrode and bar
body should be cleaned and
maintained regularly with
electrostatic brush, dust-free
cotton swab, dust-free cloth
dipped in anhydrous alcohol
according to the use
environment and the required
electrostatic protection
requirements in order to
ensure the good performance
of the product
2
The discharge electrode
ignites other metal
grounding bodies
The bar body is installed
too close to other metal
grounding bodies
Power off and clean bar body
Move the installation position of the bar
body and keep it more than 50mm away
from other metal grounding bodies to
ensure safe use and discharge performance
3
The electrostatic
removal performance
is obviously reduced
Discharge needle is
polluted and damaged
Clean or replace the ion bar
Bearing set of ion bar
is improper
Confirm the best bearing set
4
The electrostatic
removal performance
is reduced
There are conductors or
other ion bars around
Remove conductors or other ion bars
5
Unable to discharge
High-voltage connecting
wire is damaged
Return to factory for maintenance
Ion bar insulation is damaged
Return to factory for maintenance
Poor grounding/no grounding
Check the electrical grounding of ion
bar and plant equipment
6
Product burnout
Ion bar insulation is damaged
Return to factory for maintenance
1.
AP-ABAP-AB1602A explosion-proof ion bar has undergone rigorous testing and aging treatment before ex-work. Its
performance
has completely reached the relevant indicators marked in the usage instruction.
2.
AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge
within one year from the date of purchase. However, this commitment does not apply to:
(1)
The device is incorrectly used or installed.
(2)
Damage caused by negligence or accident during use.
(3)
Modified, disassembled or repaired by other service departments not authorized by Anping Company.
3.
AP&T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.