Checking Calibration

To  check  the  horizontal  calibration,  a  tripod  with  a  5/8-11  threaded 

mount, handheld detector, universal key (supplied), or a 1/16 in. (1.5 

mm) diameter pin or small nail are required. Having another person to 

help saves time if you need to adjust the calibration.

1. Set up and level the laser 100 ft (30 m) 

from a wall.
2. Point the Y- axis toward the wall. Raise/

lower the detector until you get an on-grade 

reading. Using the on-grade marking notch 

as a reference, make a mark on the wall. 

This mark is Y

1

.

Note:

  For  increased  precision,  use  the 

fine accuracy (deadband) setting on the 

detector.
3. Rotate the laser 180° (Y+ axis toward 

the wall) and re-level the laser.
4. Raise/lower the detector until you get 

an  on-grade  reading  for  the  Y+  axis. 

Using the on-grade marking notch as a 

reference, make a mark on the wall. This 

mark is Y

2

.

5. Measure the difference between the two 

marks. If they differ more than 1/8 inch at 

100 feet (3.0 mm at 30 m), the laser needs 

calibrating.

6. To correct for a calibration error, position 

the  receiver  at  the  midpoint  of  the  two 

elevation marks on the wall. This position 

is Y

3

.

Note:

 Although you can calibrate the laser 

by yourself, having another person to help 

saves time.
7.  To  adjust  the  calibration,  insert  the 

universal key (or a nail 1/16 in. or 1.5 mm 

diameter) into the opening in the calibration 

screw and turn the screw in the appropriate 

direction.

Note:

  The  arrows  on  the  display  show 

which  direction  the  calibration  screws 

need turning. An up arrow on the receiver 

indicates that the Y axis calibration screw 

needs to be turned clockwise to lower the 

laser plane. A down arrow on the receiver 

indicates that the Y axis calibration screw 

needs to be turned counterclockwise to 

raise the laser plane.
8. Rotate the laser 180° back to the original 

face. Make sure this axis is less than 1/16 

in. (1.5 mm) from the midpoint line.

Note:

 If additional adjustment is required, 

repeat steps 2-7 above.
9. After  adjusting  the  Y  axis,  rotate  the 

laser 90°. Repeat steps 2-8 starting with 

the –X axis facing the wall.

Checking Calibration

Calibration

Screws

Содержание Horizon

Страница 1: ...8261 State Route 235 Dayton Ohio 45424 USA Phone 937 482 0200 Fax 937 482 0030 www apache laser com Operator s Manual Laser System ...

Страница 2: ...gulations of the Canadian Department of Communication and is pursuant to part 15 of the Federal Communication Commission FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This laser generates radio frequency If it s not used in accordance with the instructions it may cause harmful interference to radio or television rece...

Страница 3: ...rsshouldsendproductstothenearestAuthorizedFactoryServiceCenter forwarrantyrepairs freightprepaid IncountrieswithServiceSubsidiaryCenters the repaired products will be returned to the customer freight prepaid Any evidence of negligent abnormal use accident or any attempt to repair equipmentbyotherthancertifiedfactory authorizedpersonnelorrecommended parts automatically voids the warranty Special pre...

Страница 4: ... key or small coin 3 Handle allows easy handling and safe set up of the laser 4 Battery Housing holdsfour D cellalkaline batteries 5 Recharging Jack Rechargeable battery option not available 1 3 4 5 6 7 8 9 10 11 12 2 2 9 3 6 Low Battery LED flashes when batteries need replacing 7 Rotating Prism rotates at 600 rpm to transmit the laser signal 8 Bull s Eye Level provides quick reference for front to...

Страница 5: ...e bull s eye Note Left thumb rule both thumbs in both thumbs out the bubble follows the direction of the left thumb 6 Observe the location of the bubble top or bottom of the bull s eye and using the left thumb rule turn the Y axis screw to move the level bubble to the center of the bull s eye Note When the laser is level the bubble is centered in the bull s eye and the out of level LED stops flashi...

Страница 6: ...3 0 mm at 30 m the laser needs calibrating 6 Tocorrectforacalibrationerror position the receiver at the midpoint of the two elevation marks on the wall This position is Y3 Note Although you can calibrate the laser by yourself having another person to help saves time 7 To adjust the calibration insert the universal key or a nail 1 16 in or 1 5 mm diameter intotheopeninginthecalibration screwandturn...

Страница 7: ...power switch Check or replace batteries Make sure the battery contacts are clean Make sure the battery housing is securely in place Return the laser to an authorized service center for inspection Laser out of level indicator Make sure the laser setup is stable does not shut off Make sure the leveling screws are free to turn Re level the laser and make sure the bubble is centered in bull s eye leve...

Страница 8: ...tery housing and within the leveling base Blow off any loose debris before cleaning any surfaces to prevent scratching of optical surfaces 11 Safety Information Included in this manual are CAUTIONS and Notes A CAUTION indicates a hazard or unsafe practice that could result in minor injury or property damage A Note indicates important information unrelated to safety Laser Safety This laser complies...

Отзывы: