In  addition,  the  module  can  be  used  in  conjunction  with  the  CC  Debugger  of  TI  Encoder. 

Then, users can encode and compile programs by themselves. This makes the module a valuable 

assistant for the development of ZigBee systems.

 

3.

 

Dimensions and Pin Assignments 

 

Pin    Function 

Pin  Function 

Pin  Function 

GND 

10 

+VDD 3.3V 

17 

P10 =NET LED   

GND 

11 

GND 

18 

P07 Analog IN #4 

REST_N 

12 

P13 Reserved 

19 

P06 Analog IN #3 

P22 (NC) 

13 

P12 0=C 1=R 

20 

P05 Analog IN #2 

P21 (NC) 

14 

P11 ID Clear 

21 

P04 Analog IN #1 

P17 Dout#4 

15 

P03 TX UART0 

22 

P01(NC) 

P16 Dout#3 

16 

P02 RX UART0 

23 

P00(NC) 

P15 Dout#2 

 

 

24 

+VDD 3.3V 

P14 Dout#1 

 

 

25 

GND 

P20 is reserved and not connected. 

Note:    1. Connection of Pin 10~16 is required for AO-1505/AO-1505A ZigBee to DIDO 

module, leave the remaining pins open(internal pull high). 

2. Pin assignments are defined by the users if reprogrammed. 

3. If use AT Command setting, you have to connect via 

P03

 and 

P02

 pin of UART.

 

4.

 

Function Selection and Initialization 

4.1 Function Selection 

 

 

 

 

4.2 Initialization 

Since the AO-1505/AO-1505A ZigBee to AIDO module is produced with setting any 

neither  PAN  ID  nor  NODE  ID,  initialization  is  required  before  operation.  Execute  the 

following steps to initialize the device: 

P12 

P13 

Function Description

 

Router 

  (AO-1505/AO-1505A

 has to set the router device)

 

 

 

 

 

 

 

Содержание AO-1505

Страница 1: ...APAC Opto Electronics Inc AO 1505 AO 1505A ZigBee to AIDO Module Operation Manual...

Страница 2: ...ed Output Input Pin State or Output Pin Setting Instruction 5 5 2 AO 1505 Responses Messages to Query Digital Output Pin State 6 5 3 AO 1505 Responses Messages to Query Analog Input Pin State 6 5 4 Re...

Страница 3: ...a is suitable for applications with small dimensions The AO 1505A which requires external antenna is appropriate for industrial applications in adverse environments It is noted that the AO 1505 AO 150...

Страница 4: ...P12 0 C 1 R 20 P05 Analog IN 2 5 P21 NC 14 P11 ID Clear 21 P04 Analog IN 1 6 P17 Dout 4 15 P03 TX UART0 22 P01 NC 7 P16 Dout 3 16 P02 RX UART0 23 P00 NC 8 P15 Dout 2 24 VDD 3 3V 9 P14 Dout 1 25 GND P...

Страница 5: ...software and preset 9600bps 8 N 1 3 The initialization of a coordinator must be completed prior to that of the router Furthermore the coordinator must be in working state when the router is initialize...

Страница 6: ...4 3 ID Clear and Rejoin Power ON set P12 0 press P11 set P12 1 press P11 again the setting is completed 5 AT Command Compilation Note The commands for compilation described in this section are encoded...

Страница 7: ...Direction Router Coordinator Host Format NNNNDCCCC DDDD SS String header NNNN indicates NODE ID of sent Router D indicates data port such as I Input O Output CCCC indicates channels of current command...

Страница 8: ...ata source and content are channel 2 The data content is 0x0138 and input voltage is equal to 1 872V 5 4 Remoted Sampling Mode Command To set sampling mode of all or assigned AO 1505 AO 1505A in the Z...

Страница 9: ...nquiry analog input pin status of all AO 1505 AO 1505A at the same PAN network 6 Installation and Operation 6 1 Construction of ZigBee Networks A ZigBee network must consist of a coordinator a router...

Страница 10: ...ry message AO 1503 Coordinator UART AO 1505 Router NODE ID 0001 Sensor AO 1505 Router NODE ID A247 Sensor AO 1505 Router NODE ID 0003 Sensor Analog Analog Analog A247QAI1111 AO 1505 AO 1505A QAI1111 A...

Страница 11: ...ition users don t need to understand the network configuration Under certain circumstances however if a user needs to recognize the complete network configuration he she can inquire about the informat...

Страница 12: ...ODE IDs of itself and its parent node If the responsive commands are 0000 EDA6 EDA6 9286 EDA6 383A 9286 B05C then the network configuration can be interpreted as depicted below It is noted that based...

Страница 13: ...string COMMAND MODE CR Quit command mode send ATBYE CR Successfully exit the command mode then AO 1505 AO 1505A replies OK CR 7 3 Format All command strings start with AT and the format is as follows...

Страница 14: ...22334455667788 CR Response OK CR BPS Set or Query Serial Baud rate 3 0x00 0x09 Default 0x03 Send ATBPS CR Response Baud 9600 bps CR Send ATBPS 0x04 CR Response OK CR TYE Set or Query Working Status 4...

Страница 15: ...is necessary to set P13 to 0 before power on 8 ADC Self correction Function AO 1505 AO 1505A has built in a set of 12 bit high precision analog digital converter ADC This ADC input voltage range is b...

Страница 16: ...posture to ensure good antenna radiation pattern Don t put any inductive element within 30mm distance of the module Refrain from condensation of damp or dew To ensure the PCB antenna efficiency of th...

Страница 17: ...655 Website www apacoe com tw Refer to the figures and illustrations shown below for basic electronic circuit application Note P11 GND will enforce clear of ID setting P12 3 3V the working mode is Rou...

Страница 18: ...sivity 97 92 dBm Transmission range 150 m Transmission rate 250 Kbps Interface characteristics Interface voltage level 0 3 VCC 0 3 3 6 V Interface rate 2400 9600 115200 bps General characteristics Wor...

Отзывы: