background image

Experts on Design-In 

for sensors and power solutions

Headquarter Switzerland:
Angst+Pfister Sensors and Power AG 

Thurgauerstrasse 66

CH-8050 Zurich 
Phone  +41 44 877 35 00 

[email protected]

Office Germany:
Angst+Pfister Sensors and Power 

Deutschland GmbH 
Edisonstraße 16

D-85716 Unterschleißheim
Phone  +49 89 374 288 87 0 

[email protected]

Flow / Level / Medical products

Dr. Adriano Pittarelli

Phone  +49 89 374 288 87 67 

[email protected]

Accelerometers

Sensor elements

Christoph Kleye

Phone  +49 89 374 288 87 61 

[email protected]

Harald Thomas

Phone  +49 89 374 288 87 23 

[email protected] 

Gas sensors

Gas sensor modules

Dr. Thomas Clausen

Phone  + 49 89 374 288 87

 

24

 

[email protected]

Linear position sensors

Angle sensors

Eric Letsch

Phone  + 41 44 877 35 14 

[email protected]

Drive technology

CH Postcode 1000 – 4999 / AT / IT / FR

Christian Mohrenstecher

Phone  +41 76 444 57 93

[email protected]

Pressure Sensors 

Load Cells

Philipp Kistler

Phone  + 41 44 877 35 03 

[email protected]

Power supplies 

Sebastiano Leggio

Phone  + 41 44 877 35 06 

[email protected]

Drive technology

CH Postcode 5000 – 9999 / DE

Roman Homa

Phone  + 41 76 444 00 86 

[email protected]

Sales Other Countries / Product Management

Sales International Key Accounts

Peter Felder

Phone  + 41 44 877 35 05

[email protected]

Postcode 1000 – 2999

Christian Mohrenstecher

Phone  +41 76 444 57 93

[email protected]

Sales Switzerland & Liechtenstein

Postcode 3000 – 9999

Basil Frei

Phone  + 41 44 877 35 18

[email protected]

Gas sensors and modules

Peter Felder

Phone   +41 44 877 35 05 

[email protected] 

Pressure sensors

Other products

Gerhard Vetter 

Phone  + 49 89 374 288 87 26 

[email protected]

Sales Germany & Austria

 

Geometrical sensors

Other products

Kurt Stritzelberger

Phone  + 49 89 374 288 87 22 

[email protected]

We are here for you. Addresses and Contacts.

Содержание PSX120 Series

Страница 1: ...might destroy the sensor The rope must be extracted from the sensor vertically The maximum variation from the vertical is 3 Avoid extracting the rope at an inclination since the durability of the instrument would shorten considerably If it is not possible to keep the limit of 3 a deflection pulley has to be used Guide the rope preferably in corners or guarded in channels to prevent pollution or ac...

Страница 2: ... M5 x 6 20 30 60 17 25 2 x M4 17 25 2 x M4 100 Mounting rope outlet sideways bottom S2 rope outlet bottom S3 Sensors with option rope outlet S2 and S3 have a modified base plate SX50 SX80 SX120 60 20 Ø 4 5 10 5 C Option S2 Option S3 Option S2 Option S3 30 9 25 13 8 95 Ø 6 5 19 7 140 Ø 6 5 Option S2 Option S3 13 75 30 Measurement range mm Option C 50 150 250 Standard 21 3 75 225 750 Standard 17 100...

Страница 3: ...CTRICAL CONNECTION INCREMENTAL OUTPUT SX50 SX80 SX120 Connector output M12 male 8 pins Signal GND V A A B B Z Z Pin 1 2 3 4 5 6 7 8 1 2 5 4 3 7 6 8 SX80 SX120 Connector output M23 male 12 pins Signal GND V A A B B Z Z GNDsens Vsens n c Pin 10 12 5 6 8 1 3 4 11 2 7 9 2 1 5 6 7 3 4 8 9 10 11 12 SX50 SX80 SX120 Cable output Signal GND V A A B B Z Z GNDsens 1 Vsens 1 Cable colour WH BN GN YE GY PK BU ...

Страница 4: ... D Pin 1 2 3 4 5 6 Signal SET DIR Status n c H Pin 7 8 9 10 11 12 shield 1 2 5 4 3 7 6 8 2 1 5 6 7 3 4 8 9 10 11 12 ELECTRICAL CONNECTION CANopen SX50 Cable output 1 Signal GND V CAN_L CAN_H CAN_GND Cable colour WH BN YE GN GY SX80 SX120 2 x Connector output M12 Bus OUT female Bus IN male Signal GND V CAN_L CAN_H CAN_GND GND V CAN_L CAN_H CAN_GND Pin 3 2 5 4 1 3 2 5 4 1 2 1 3 4 5 1 2 4 3 5 SX80 SX...

Страница 5: ...nal BUS_VDC 1 PB_A BUS_GND 1 PB_B shield 2 1 3 4 5 Pin 1 2 3 4 5 1 for supplying an external Profibus termination resistor ELECTRICAL CONNECTION EtherCAT PROFINET SX50 SX80 SX120 3 x Connector output M12 Bus IN or Bus 1 Signal Transmit data Receive data Transmit data Receive data Acronym TxD RxD TxD RxD Pin 1 2 3 4 Power supply Signal Voltage n c Voltage n c Acronym V n c 0 V n c Pin 1 2 3 4 Bus O...

Страница 6: ...shielded K8P10M SW M12 10 m angular connector IP67 shielded Pin 1 2 3 4 5 6 7 8 Cable colour WH BN GN YE GY PK BU RD Cable with mating connector M23 female 12 poles K12P2M S M23 2 m straight connector IP67 shielded K12P5M S M23 5 m straight connector IP67 shielded K12P10M S M23 10 m straight connector IP67 shielded K12P2M SW M23 2 m angular connector IP67 shielded K12P5M SW M23 5 m angular connect...

Страница 7: ...nector M12 male 5 poles K5P2M S M12 CAN 2 m straight connector shielded Pin 1 2 3 4 5 Cable colour shield RD BK WH BU 2 1 3 4 5 1 2 4 3 5 Digital output EtherCat and Profinet Bus In Bus Out Cable with mating connector M12 female 4 poles K4P2M S M12 CAT 2 m straight connector shielded K4P5M S M12 CAT 5 m straight connector shielded K4P10M S M12 CAT 10 m straight connector shielded 1 2 4 3 Pin Cable...

Страница 8: ...ds to corrosion Where applicable use option S3 MAINTENANCE The devices are maintenance free If however the rope is soiled due to adverse environmental conditions it can be cleaned with a cloth drenched in resin free machine oil DECLARATION OF EU CONFORMITY Classification Product series This is to certify that the products draw wire sensors PSX fulfill the current request of the following EU direct...

Страница 9: ...Christian Mohrenstecher Phone 41 76 444 57 93 christian mohrenstecher angst pfister com Pressure Sensors Load Cells Philipp Kistler Phone 41 44 877 35 03 philipp kistler angst pfister com Power supplies Sebastiano Leggio Phone 41 44 877 35 06 sebastiano leggio angst pfister com Drive technology CH Postcode 5000 9999 DE Roman Homa Phone 41 76 444 00 86 roman homa angst pfister com Sales Other Count...

Отзывы: