background image

 

 

AIR QUALITY 
MOBILE

 

50P 

Jan 2012 

 
 

 

Automatikprodukter 

 

7 . 1  

C O N T R O L   P A N E L  

 
All information regarding the operating status of the machine is displayed on the control panel. 
The control panel allows the user to: 
- select the air flow  
- activate/deactivate environmental revitalisation 
- turn off any alarms indicating apparatus malfunctions 
- constantly control all the functions relating to operation (air flow, environmental revitalisation, 
  filtration efficiency, alarm situation). 
 

 

 
The devices which permit manual operation and visual control of the operating conditions are given here 
below. 
 

7 . 1 . 1  

D I S P L A Y  

 
When the machine works normally, the single-figure display shows the operating air flow (0-1-2-3). 
If, on the other hand, the letter F appears, this means that operation of the electrostatic cell is not correct. 
The reason may be a deposit of pollutant on the surface of the ionisation wires (see paragraph 
"ELECTRONIC CIRCUIT ALARM SIGNALS"). 

 

If the letter F appears together with the indication ALARM, the operation of the Revitaliser does not 
stop, however it is an indication of efficiency reduction.

 

                 

 

 

7 . 1 . 2  

R E C E I V E R  

 

 

The receiver permits the reception of the signal coming from the infrared remote 
control unit to obtain speed changes, activation of the night-time deodorization 
phase or switching off of the apparatus; if one of the four remote control buttons 
has been pressed, the Led flashes for about 1 second. 

 

 
The control panel is divided in three zones: 
1 – COMMANDS AND VISUALISATION OF 
      THE SPEED 
2 – FILTERING STATUS  
3 – OPERATION OF THE APPARATUS  
 

Содержание LifePro50p

Страница 1: ...AIR QUALITY MOBILE 50P Jan 2012 Automatikprodukter USERS MANUAL AND INSTALLATION GUIDE...

Страница 2: ...AIR QUALITY MOBILE 50P Jan 2012 Automatikprodukter...

Страница 3: ...1 Access Door 13 5 1 2 Washing the filters 14 5 2 GENERAL INSPECTION OF THE FILTERS 15 5 3 CLEANING THE MACHINE 15 6 AVAILABLE VERSIONS 16 7 NATURE SYSTEM 18 7 1 CONTROL PANEL 19 7 1 1 DISPLAY 19 7 1...

Страница 4: ...IRCUIT ALARM SIGNALS 32 8 10 ELECTRONIC CIRCUIT ANOMALOUS SIGNALS 33 9 BASIC SYSTEM 34 9 1 CONTROL PANEL 35 9 2 VISUALISATION OF SPEED 35 9 2 1 RECEIVER 35 9 2 2 MANUAL AND ON OFF FILTER BUTTONS 36 9...

Страница 5: ...M A C H I N E identification plate There is a plate in every machine showing the model and the series number which identify the machine This plate is located on the inside of the machine and it is the...

Страница 6: ...M A R K I N G O F T H E M A C H I N E The EC conformity mark is located on the control panel of the machine 1 2 1 O p e n i n g t h e d o o r For opening the door it is necessary to introduce a finger...

Страница 7: ...nary maintenance or repairs The following objects should be found in the box the required machine users manual and guarantee leaflet remote control unit plug 2 2 T R A N S P O R T To limit damage and...

Страница 8: ...A T I O N O F T H E M A C H I N E For a correct function place the machine so that the air can fulfil the cycle as figured on the picture The air that comes out of the hinder air diffuser must not fin...

Страница 9: ...o the average number of people present in them To calculate the quantity of air in m3 h to introduce from the exterior it is sufficient to multiply the average number of persons present by a coefficie...

Страница 10: ...llutant particles with an efficiency of 99 Its dimensions vary depending on the model it is fitted in DIMENSIONS FILTER MODEL A B C 50p 344 310 115 The cell is built entirely in anticorodal aluminium...

Страница 11: ...electrical connection is made between the electronic circuit and the electrostatic cell During maintenance inspect to ensure that the flexible arches are intact Also ensure that there are no burns or...

Страница 12: ...THE MACHINE 4 2 1 E l e c t r o n i c c i r c u i t p r o t e c t i o n d e v i c e s The electronic circuit is provided with a series of protection devices which automatically cut off the high voltag...

Страница 13: ...ion of the machine Extraordinary maintenance is carried out by specialised personnel 5 1 F I L T E R M A I N T E N A N C E To carry out filter maintenance it is necessary to gain access to them throug...

Страница 14: ...the filters 4 Vinegar Prepare the tray with the raised bottom with warm water max 45 C Dilute the detergent in the proportions indicated on the label of the detergent itself Put the vinegar and water...

Страница 15: ...H E F I L T E R S The state of the filters must be inspected every time they are washed so as to prevent air cleaner malfunction and problems INSPECTION FAULT OPERATION ionisation wires breakage of a...

Страница 16: ...librium inside a confined environment as close as possible to the ideal one for well being ENVIRONMENTAL REVITALIZER RIVITALIZZATORE AMBIENTALE Identifies the apparatus which in an equilibrated manner...

Страница 17: ...esture in complete autonomously way the parameters of the filtration depending from the chosen performance of function and the level of saturation of the electrostatic cell HIGH EFFICIENCY FILTERING I...

Страница 18: ...operating status of the apparatus Infrared remote control unit The remote control unit allows the user to control the operation of the Revitalizer from a distance of about 6 7 metres in particular th...

Страница 19: ...erating air flow 0 1 2 3 If on the other hand the letter F appears this means that operation of the electrostatic cell is not correct The reason may be a deposit of pollutant on the surface of the ion...

Страница 20: ...o completely dry the filtering unit after washing or to use the machine for the ventilation function only The RESET button is for turning off the ALARM signal if the circuit protection device has trip...

Страница 21: ...enance flow room half empty sets the normal use flow room half full sets the emergency flow room crowded turns off the air purifier How to use point the remote control towards the control panel taking...

Страница 22: ...re Reduction Cardiovascular system Improvement Metabolism Increase Allergies Reduction Respiratory capacity Improvement Insomnia Reduction Mental concentration Increase The Revitalizer only goes off w...

Страница 23: ...ing phase by turning the Revitalizer to one of the 3 speeds available by means of the remote control unit or the MANUAL button 7 8 S I G N A L S The electronic control of this apparatus provides the u...

Страница 24: ...bars casinos discos pubs amusement arcades etc TYPE B suitable for premises such as restaurants pizzeria cafes ice cream parlours butcher shops etc TYPE C suitable for premises such as shops and store...

Страница 25: ...ain yellow LED on PRE ALARM small bodies trapped between the collection blades the foreign bodies deposited on the blades must be removed red LED on MAINTENANCE electrostatic cell very dirty carry out...

Страница 26: ...ate when the Revitalizer is working The other two cases are due to activation of particular test programs due to the simultaneous pressure of two buttons on the control panel of the circuit To elimina...

Страница 27: ...information required on the operating status of the apparatus Infrared remote control unit The remote control unit allows the user to control the operation of the machine from a distance of about 6 7...

Страница 28: ...flow 0 1 2 3 If on the other hand the letter F appears this means that operation of the electrostatic cell is not correct The reason may be a deposit of pollutant on the surface of the ionisation wire...

Страница 29: ...ed when you need to completely dry the filtering unit after washing or to use the machine for the ventilation function only The RESET button is for turning off the ALARM signal if the circuit protecti...

Страница 30: ...the normal use flow room half full sets the emergency flow room crowded turns off the air purifier How to use point the remote control towards the control panel taking care that you are in line with i...

Страница 31: ...EST ON OFF FILTER buttons 8 8 S T A T E O F F I L T R A T I O N E F F I C I E N C Y As described in paragraph CONTROL PANEL the three Leds of FILTRATION STATUS provide indications on the state of filt...

Страница 32: ...gain yellow LED on PRE ALARM small bodies trapped between the collection blades the foreign bodies deposited on the blades must be removed red LED on MAINTENANCE electrostatic cell very dirty carry ou...

Страница 33: ...llate when the machine is working The other two cases are due to activation of particular test programs due to the simultaneous pressure of two buttons on the control panel of the circuit To eliminate...

Страница 34: ...tive ionisation along with the information required on the operating status of the apparatus Infrared remote control unit The remote control unit allows the user to control the operation of the machin...

Страница 35: ...ices which permit manual operation and visual control of the operating conditions are given here below 9 2 V I S U A L I S A T I O N O F S P E E D 9 2 1 R E C E I V E R The receiver permits the recept...

Страница 36: ...I T The remote control unit allows you to control the machine modifying the air flow from a distance of about 6 7 metres The following functions are provided How to use point the remote control towar...

Страница 37: ...can be resolved by a small operation TYPE OF ALARM CAUSE OPERATION green Led FILTER OK is flashing electrostatic cell dirty carry out normal maintenance electrostatic cell not properly clean if small...

Страница 38: ...used to build them 1 1 1 C E R T I F I C A T I O N C N R The machines are in possession of C N R certification which attests to the efficiency of filtration declared for each model and certifies that...