6
CONTROL PANEL GUIDE
A
-
Set temperature for type 0 and 1 operation.
b
-
Actual Temperature of Sensor 1 (Marked B)
c
-
Actual Temperature of Sensor 2 C
D
-
Actual Temperature of Internal Sensor
C
-
Set Temperature for profile.
t
-
Set duration/time (seconds) for profile.
1.a
5
4
3
2
6
7
Front Panel
Back Panel
9
8
1.b
1 — Digital Display
1.a Top Display
1.b Bottom Display
2 — Selection button.
3 — Increase Button/ Enter button.
4 — Decrease Button.
5 — Status LED.
6 — External Sensor connector
7 — Main Power switch.
8 — Power cord attachment.
9 — Fuse holder.
LEGEND:
Suffix guide:
7
OPERATING PROCEDURES
A. INITIAL PROCEDURES
1. Make sure all switches are deactivated.
2. Attach external sensor probes to the three pin socket. (#6 on control
panel guide)
3. Attach power cord to the power cord attachment (#8 on control panel
guide)
4. Plug the device to the main power source.
5. To turn the unit ON. Toggle the main power switch to ON position (#7
on control panel guide)
B. OPERATION TYPE(MODE) SELECTION
1. Follow initial procedures, “A. INITIAL PROCEDURES”.
2. The display would show “TYPE 0”, which means Type 0 operation will
be used. To select between types 0 to 2. Press the increase or
decrease buttons (#3 & #4 of control panel guide).
3. To confirm selection and enter into operation mode using the selected
type. Press the selection button.(#2 of control panel guide)
C. TYPE “0” OPERATION
This type of operation utilizes the internal temperature sensor to control
the heat. Using this type frees up the two extra external temperature
probes for additional monitoring. Attach the two extra temperature probes
to areas of interest such as the bottom of the board and top of the board
near the components to be worked on for monitoring.
1. To set the desired temperature press the selection button repeatedly
until the top display shows “Set”. The bottom display would show the
current set temperature followed by a suffix “A”.
2. Press the increase or decrease button to adjust the set temperature
level. The set temperature is adjustable from 50 to 400 C in this type
of operation.