IMPORTANT REMINDERS: 

1. Make sure the equipment is placed on a flat stable surface 

and all the heat-generating components placed on their re-
spective holders or stands. 

2.  Ensure all function switches are OFF prior to reworking. 
3.  Ensure all terminal connections are properly secured. 

IMPORTANT:  Please  refer  to  the  CONTROL  PANEL  GUIDE  page  for 

buttons and display panel directory. 

A. INITIAL PROCEDURES 
1.  Plug the device to the main power source using the power cord 

provided in the package. 

2.  With all function switches deactivated and all terminal connections 

properly secured, switch ON the device by activating the main power 
switch. 

3.  The display panels, B1 and B1 will temporarily show the product name 

in a scrolling manner and then display “OFF” on all rows once the 
scroll is finished. The system will remain at this state until the user 
activates a function. 

ASSEMBLY and PREPARATIONS 

OPERATING GUIDELINES 

(FOR Int 852A++ pro  only) 

Loosen the two screws that on the side 
of the station. 
 

Fasten the two 
screws. 

Align the vacuum pen holder 
legs with the two screw holes. 
 

 9 

OPERATING GUIDELINES 

B. HOT AIR GUN 
1.  Follow the initial procedures above, “A. INITIAL PROCEDURES”. 
2.  Activate “Hot Air Gun” switch (“F” from the control panel).  
3.  The system will immediately start to blow air and increase the air 

temperature according to the set values.  

4.  Adjust the air flow level using the airflow control buttons (“C3 and 

C4” from the control panel).  

5. 

Adjust the hot air gun air temperature using the temperature 
control buttons (“C1 and C2” from the control panel). The display 
for Hot Air Gun Temperature will change from actual temperature 
display to set temperature display while temperature is being 
adjusted. When set temperature adjustment is done wait a few 
seconds for the display B1 to return to displaying the actual 
temperature.  

6. 

When reworking is complete, return the Hot Air Gun to its holder 
and DO NOT immediately turn off the main power switch. 

7. 

Deactivate the Hot Air Gun Function button first in order to 
activate the auto-cooling process. The system will start to blow 
air (at room temperature) at a fast rate to reduce heat from the 
hot air gun and bring down the temperature to a reasonable safe 
level of 80°C. During this time, the display for hot air gun 
temperature will also alternate from “Off” to actual temperature 
display. Likewise, the air pressure level is at its highest reading as 
indicated from the air flow gauge. Once the temperature drops to 
approximately 80°C  the system will halt and display “OFF” on the 
panel. It is now safe to switch off the main power switch.  

8. 

Turn OFF the main power switch. 

9. 

Unplug the device from the main power source. 

IMPORTANT: 

When adjusting the air temperature, it is strongly advised 

to initially increase the airflow level in order to

 

manage

 

the

 

system tem-

perature. This is to protect the heating element inside the handle from 
excessive heat. 

Содержание Int 852A++ pro

Страница 1: ...ttp www aoyue com SMD Rework Station INSTRUCTION MANUAL Thank you for purchasing Aoyue int 852A pro int 852A pro SMD Rework Station It is important to read the manual before using the equipment Please...

Страница 2: ...shooting Guide 14 Air Nozzles 15 This manual is designed to familiarize and instruct the op erator with the proper usage and maintenance of the equipment The Care and Safety Precautions section explai...

Страница 3: ...enter of the base of the main unit has been removed This holds the pump in place during transportation and needs to be removed before using the equipment PROBLEM 6 UNIT SHOWS UNCONVENTIONAL BEHAVIOR D...

Страница 4: ...needed the following procedure can be done 1 Follow System Setting procedures 1 to 6 Adjust system selection menu to SEL 4 then press the air flow control up button C3 2 If successful the display B2 w...

Страница 5: ...y please observe the ff precautions Check each component after opening the package to make sure everything is in good condition If there are any suspected damage do not use the item and report the iss...

Страница 6: ...t 60 indicating soldering iron sleep timer setting is being set 4 Adjust the sleep timer with the air flow control buttons C3 and C4 Sleep timer is adjustable from 5 to 60 minutes with t OFF signifyin...

Страница 7: ...ing the procedures below 1 Turn off unit 2 Ensure that the Hot Air gun function switch F is in the ON position 3 Power ON unit by switching the power switch to ON 4 While the AOYUE name is scrolling s...

Страница 8: ...the air flow level using the airflow control buttons C3 and C4 from the control panel 5 Adjust the hot air gun air temperature using the temperature control buttons C1 and C2 from the control panel T...

Отзывы: