background image

12

 

OPERATING GUIDELINES 

 

To let system save the desired sleep timer value into the memory, 

simply   let   go   of   the   adjustment   knob   and   the   system   will 

automatically save the value into CPU memory. 

3.  Turn  on  the  soldering  iron  function  switch  to   start  using  the 

soldering iron. 

4.  The  sleep  timer  will  start  counting  down  once  the  soldering  iron 

function  switch  is  turned  ON  and  no  adjustments  are  made  to 

soldering iron set temperature. 

5.  When  the  timer  expires,   the  soldering  iron  will   shut  down  its 

heater   and   display   three   dashes   “­  ­  ­  “.   This   indicates   the 

soldering iron is in sleep mode. 

6.  To wake the soldering iron simply adjust the temperature knob A3. 

7.  To disable the sleep timer simply set the sleep timer duration to 0. 

8.  Access and disable the sleep feature of the soldering iron: 

 

Turn Soldering iron, SMD and Smoke absorber function switch off. 

 

Press and hold the hot air temperature increase button A6. 

 

The  soldering  iron  display  A2  will  turn  to  “t##”  ,  indicating  it  is 

now on sleep timer adjustment mode. 

 

Turn  the  soldering  iron      adjustment  knob  completely  counter 

clockwise to set timer to “t00”. 

 

let system save the desired sleep timer value into the memory.

 

SOLDERING IRON DIGITAL CALIBRATION 

1.  The soldering iron has a digital calibration feature that allows the 

user to easily adjust the temperature offset of the soldering iron + 

or—50 degrees. 

2.  Rest the calibration number of the soldering iron: 

 

Turn SMD and Smoke absorber function switch off. 

 

Turn Soldering iron function switch on. 

 

Press and hold the hot air temperature increase button A6. 

9

 

SMD REWORKING 

1.  Ensure All function switches (B1,B2,B3) are in off position. 

2.  With  the  unit  plugged  to  the  main  power  source,  turn  on  the 

system by switching the main power switch on. The panel should 

initially   display   the  product    name  in  a  scrolling  manner  and 

display OFF on panel C2 after.

 

NOTE: 

The product name may scroll more than once upon plugging the 

system  to  the  power  source.  The  system  is  trying  to  determine  the 
appropriate  operating  frequency  based  on  the  user  location.  See  Basic 
Troubleshooting Guide  (page 14­15).

 

2.  Turn ON the

 “SMD Rework” 

function switch, B3. 

3.  The system will start to blow hot air and increase the temperature 

to  90°C,  by  default.  Display  panel,  C2,  shows  the  user­defined 

(set)   temperature   while   display   panel,   C3,   shows   the   actual 

temperature of the system. 

4.  Adjust  air  pressure  by  turning  knob  A1.  It  is  recommended  to 

keep  the  knob  setting  at 3  or  above. It is  also  advised  to  adjust 

the  airflow  level  first  before  increasing  the  air  temperature  to 

avoid  building  of  too  much  heat  on  the  hot  air  gun  thus  burning 

the heating element.

 

NOTE: 

If  air  pressure  knob  is  set  to  minimum  upon  switching  the  SMD 

Rework  ON,  the  system  will  automatically  run  at  average  airflow  to  protect 
the device from excessive heat. The user will gain full control once the knob 
has been adjusted to the desired airflow level.

 

OPERATING GUIDELINES

Содержание 968A+

Страница 1: ...rsonnel or damage to items in the workplace may result if not carefully used Please read the contents on how to use the equipment and observe the following in order to maximize usage After opening the...

Страница 2: ...rflow level is noticeably weaker SOLUTION Try to press the Reset button on the panel and let the device re detect the proper operating frequency Note that resetting the device will also reset all prev...

Страница 3: ...ading is not increasing or decreasing based on desired level set temperature The panel will then display a blinking OFF on display panels C2 and C3 afterwards SOLUTION The heating element may be broke...

Страница 4: ...s Easily adjust temperature offset with a few simple adjustments Intelligent error reporting mechanism Detects and informs the personnel for problems with the sensor and heating element Auto cooling f...

Страница 5: ...nt and reconnect the terminal Be careful not to rub or touch together the heating element wire 6 Reconnect the ground wire after replacing the heating element 7 Re assemble the handle NOTE The life ex...

Страница 6: ...te temperature when soldering 2 Cleaning Always clean the soldering tip before using Remove any residual solder or flux that are still adhering to the tip Use a clean and moist cleaning sponge to remo...

Страница 7: ...error SOLDERING IRON SMOKE ABSORBER 1 Turn on Soldering Iron function and set to desired working temperature Wait for soldering iron to reach set temperature 2 Turn on the Smoke Absorber function swi...

Страница 8: ...ration value into the memory 3 Set soldering iron to desired working temperature 4 Wait a few minutes for the temperature to stabilize before checking the temperature difference with an external calib...

Страница 9: ...st the calibration number of the soldering iron Turn SMD and Smoke absorber function switch off Turn Soldering iron function switch on Press and hold the hot air temperature increase button A6 9 SMD R...

Страница 10: ...A2 will show the current set temperature based on the knob position 11 OPERATING GUIDELINES 5 After a few seconds the digital display A2 will switch to showing the actual temperature You may start sol...

Отзывы: