12
OPERATING GUIDELINES
●
To let system save the desired sleep timer value into the memory,
simply let go of the adjustment knob and the system will
automatically save the value into CPU memory.
3. Turn on the soldering iron function switch to start using the
soldering iron.
4. The sleep timer will start counting down once the soldering iron
function switch is turned ON and no adjustments are made to
soldering iron set temperature.
5. When the timer expires, the soldering iron will shut down its
heater and display three dashes “ “. This indicates the
soldering iron is in sleep mode.
6. To wake the soldering iron simply adjust the temperature knob A3.
7. To disable the sleep timer simply set the sleep timer duration to 0.
8. Access and disable the sleep feature of the soldering iron:
●
Turn Soldering iron, SMD and Smoke absorber function switch off.
●
Press and hold the hot air temperature increase button A6.
●
The soldering iron display A2 will turn to “t##” , indicating it is
now on sleep timer adjustment mode.
●
Turn the soldering iron adjustment knob completely counter
clockwise to set timer to “t00”.
●
let system save the desired sleep timer value into the memory.
SOLDERING IRON DIGITAL CALIBRATION
1. The soldering iron has a digital calibration feature that allows the
user to easily adjust the temperature offset of the soldering iron +
or—50 degrees.
2. Rest the calibration number of the soldering iron:
●
Turn SMD and Smoke absorber function switch off.
●
Turn Soldering iron function switch on.
●
Press and hold the hot air temperature increase button A6.
9
SMD REWORKING
1. Ensure All function switches (B1,B2,B3) are in off position.
2. With the unit plugged to the main power source, turn on the
system by switching the main power switch on. The panel should
initially display the product name in a scrolling manner and
display OFF on panel C2 after.
NOTE:
The product name may scroll more than once upon plugging the
system to the power source. The system is trying to determine the
appropriate operating frequency based on the user location. See Basic
Troubleshooting Guide (page 1415).
2. Turn ON the
“SMD Rework”
function switch, B3.
3. The system will start to blow hot air and increase the temperature
to 90°C, by default. Display panel, C2, shows the userdefined
(set) temperature while display panel, C3, shows the actual
temperature of the system.
4. Adjust air pressure by turning knob A1. It is recommended to
keep the knob setting at 3 or above. It is also advised to adjust
the airflow level first before increasing the air temperature to
avoid building of too much heat on the hot air gun thus burning
the heating element.
NOTE:
If air pressure knob is set to minimum upon switching the SMD
Rework ON, the system will automatically run at average airflow to protect
the device from excessive heat. The user will gain full control once the knob
has been adjusted to the desired airflow level.
OPERATING GUIDELINES