L. Utilizing the Hot Air Gun Digital Temperature Calibration
By default, the system is properly calibrated but for some cases
when a little adjustment of the Hot Air Gun temperature is required
the following procedure can be done.
1. Follow System Setting procedures 1 to 6. Adjust system
selection menu to Set 006, then turn the hot air gun set
temperature knob to off position.
2. If successful the display would show “ 0FSt 024” indicating hot air
gun digital calibration is being set.
3. Adjust the air flow adjustment knob “A2” to enter desired offset
value, Calibration value is adjustable from –70 to 70 degrees with
“000” signifying no offset.
4. Save the selected calibration settings and exit from the calibration
adjustment menu by turning the soldering iron set temperature
knob to off position.
5. Enter hot air gun function and set to desire temperature to check
if additional calibration is needed.
15
DIGITAL CALIBRATION