![AOS X-EMA Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/aos/x-ema/x-ema_manual_2951388028.webp)
A O S H i g h S pe ed Cam e ra s
V e rs i o n 2. 0
C o p y r i g h t
©
A O S T e c h n o l o g i e s A G
P a g e 2 8 o f 3 1
Specifications
Software:
“Point and click” environment for Windows 2000 / XP Pro.
Computer requirements:
Minimum Pentium 4, 2GHz with MMX, 1024x768 display, 1GB RAM, 60GB Hard Drive, GigE
Data Interface
File Formats:
AVI, AOS RAW, MPEG, BMP, JPEG, GIT, TIFF
CMOS Sensor Resolution:
1280x1024 Pixels, each pixel 12 microns square. (8-bit mono) at 500 fps
Record Rates:
Up to 4’000fps by reducing the vertical resolution (X-PRI)
Up to 32’000fps by reducing the vertical resolution (X-MOTION / X-VIT / X-EMA)
Exposure Rates:
Global Electronic Shutter with exposure times from 1 microseconds to 1/frame rate in
increments of 1 microsecond.
Recording Modes:
Circular Buffer:
Records images into circular buffer until triggered, then a user-selectable number of post-
trigger frames (from 0 to the total number of pages in buffer –1) are recorded.
Record on Trigger:
The trigger position is selectable to any number between 0 and the page capacity –1.
Frame Storage:
1,024 pages (1.3 gigabytes of memory)
2,048 pages (2.6 gigabytes of memory)
4,096 pages (5.2 gigabytes of memory)
Playback Rates:
depending on PC speed.
Trigger:
TTL (5V-tolerant) compatible signal; User-selectable polarity.
Lenses:
Standard C-mount (1” format)
External Connections:
LEMO 14-pin Connector for I/O signals.
RJ45 connector for Gigabit Ethernet Data signals.
Size:
120 x 71 x 71mm (without CF+ Interface)
133 x 71 x 71mm (with CF+ Interface)
Weight:
Camera Head: 0.8 kg
Power:
9…16VDC (external power supply)
10W power consumption (Data link not established)
15W power consumption (Data link established)
Operating temperature:
X-PRI / X-MOTION: 0…+40° C / X-VIT: -15…+45° C, X-EMA: -40…+50° C
Storage temperature:
All cameras: -40…+70° C
Humidity:
Operational: max. 80%, non-condensing, at 45° C (113° F) for 8 hours. Non-operational: max.
40%, non-condensing, at 70° C (158° F) for 48 hours.
Shock:
100 g peak sinusoid pulse with 15 ms pulse width (X-VIT / X-EMA only)
All manuals and user guides at all-guides.com