- 36 -
SC
Set operating code for option (not available in the UK).
The SC command is used to review and select the operating code if the option is
fitted to the AR8000. LSB is used to control the optional unit.
To review the current selection of code use the command SC[
ï
]
The response will be in the format SCnn where nn = 00 ~ 7F (HEX DECIMAL)
Some units may only have four operating codes, in this case the lower end of 2BIT
is used. They are identical in operation: 01 05 09 0D 25 39 5D 79
To change the current code use the format SCnn[
ï
] where nn is the desired
operating code.
Related command SI
SD
Change HOLD / DELAY time in search mode.
The SD command is used to review and change the setting of HOLD / DELAY time
when in search mode.
To review the current setting use the command SD[
ï
]
The response will be in the format:
SDnn where nn = 01 ~ 99 DELAY in tenths of seconds (100mS)
nn = FF HOLD
nn = 00 DELAY OFF
Examples are:
SD65 = DELAY of 6.5 seconds
SD52 = DELAY of 5.2 seconds
SDFF = HOLD ON
SD00 = DELAY OFF
To change the current setting of HOLD / DELAY in search mode use the format
SDnn[
ï
] where: nn = 01 ~ 99 DELAY in tenths of seconds (100mS)
nn = FF HOLD
nn = 00 DELAY OFF
Related commands BQ BS SA SB SG SO SP SQ