10
2-2 RESPONSE FORMAT
Although there is no local echo, a specified response should come back from the AR5001D after
confirming the correct command.
If an invalid command is sent to the AR5001D, ? <CR><LF> (0x3f, 0x0d, 0x0a) will be returned
as an unrecognized command.
<SP><CR><LF> (0x20, 0x0d, 0x0a) to a valid command (without parameter).
<command><value><SP><CR><LF> to a valid command (with parameter.)
2-3 POWER ON/OFF THE AR5001D
2-3-1 WAKE UP
Any
key
Power on
Wake up from stand-by mode (QP command)
Note: The main power switch must be in the ON position.
2-3-2 STANDBY MODE
QP
Switches the AR5001D
to standby mode
The main power switch must remain in the ON position.
2-3-3 SLEEP TIMER
QT
Sleep Timer
QTnn
:00 ~ 60 (in minute) (1 minute step) (default: 00)
To read
: QT<CR>
Response
: QTnn
TR
Sleep Timer Display
(Displays remaining
time)
TR0
: display off
TR1
: display on (default) (Respond by QT parameter)
To read
: TR<CR>
Response
: TRn
2-3-4 END REMOTE CONTROL
EX
End remote control
2-4 AUDIO GAIN
VL
VLnnn
(nnn: 000 ~ 255)
To read:
VL<CR>
Response:
VLnnn
2-5 STEP FREQUENCY
ST
STnnnnnn
(entry in Hz format) (nnnnnn: 0 ~ 999.999 (kHz))
If a decimal is included in “n”, it will be recognized as kHz
format.
When “0” is entered, it will be recognized as 1000 kHz,
(default:100.0kHz)
All manuals and user guides at all-guides.com