
47
Code 93
Read:
Format
Data digits (variable) 2 check digits (optional)
Check digit verification: The check digit is made as the sum module 47 of the numerical values of all data
digits.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of Code 39.
Code ID setting: Refer to Code ID setting of UPC-A.
Insertion group selection: Refer to Insertion group selection of UPC-A.
SETUP
Option bar code
Option
Alpha. entry
Read
Disable
Enable
00
01*
Check digit verification
Disable
Enable
00
01*
Check digit transmission
Disable
Enable
00*
01
Max. code length
00-99
00-99
00*
Min. code length
00-99
00-99
01*
Code ID setting
00-FF
16
(ASCII)
00-FF
16
<L>*
Insert group selection
00-66
00-66
00*
Reserved
END
Содержание AS260
Страница 1: ...AS290 AS260 Cordless Barcode Scanner User Manual Version AS290 AS260_UM_EN_V1 2 7 AOPOS...
Страница 15: ...5 Decode zone High density series Long range series...
Страница 16: ...6 Dimensions...
Страница 39: ...29 SETUP Option bar code Option Alpha entry END...
Страница 85: ...75 Configuration alphanumeric entry barcode...