![AOpen A70PF Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/aopen/a70pf/a70pf_service-manual_2950766008.webp)
A70PF(RX-777NS) 8 / 33
ITEM
Program Menu.
﹟
Test Meter
﹡
Test Point
﹫
Pattern
Operation
Adjusting
Value
D
Background
White
Balance
Adjust
﹟
Color Analyzer
﹫
R.G.B off
(68KHz,1024x768)
1.
Set the contrast to MAX.,Brightness to Y=0.7
set color is 9300
°
K
using the OSD.
2.
Set the OSD to COLOR of sub menu and press
knob.
3.
Make the adjustment R.G.B BIAS low light to
the value shown at right by using and key.
Y = 0.4
±
0.1FL
x = 0.283
±
0.015
y = 0.297
±
0.015
E
White
Balance
Adjust
﹟
Color Analyzer
﹟
Oscilloscope
﹡
Cathode G
﹫
3” block
(68KHz,1024x768)
1.
Move the OSD to the R.G.B. DRIVE.
2.
Move the OSD to the G DRIVE and make the
adjustment to the value shown at right by using
and key.
3.
Move the OSD to the R,B-DRIVE and make the
Adjustment to the value shown at right by using
and key.
37V
P-P
Y=58FL
x = 0.283
±
0.015
y = 0.297
±
0.015
F
ABL
Adjust
﹟
Color Analyzer
﹫
Full White
(68KHz,1024x768)
1.
Set the contrast to MAX.,Brightness to MAX.
2.
Make the adjustment to the value shown at right
by adjustment
ABL
on the OSD menu.
Y =
33FL
±
3
G
Other
Function
Seting
﹫
Full White
(85Hz 1024*768)
1.
Set the
FREQ.
to 73
2.
Set the
OSD
to PROVIEW
3.
Set the
BURN
to Disable
4.
Set the
DEFO
to TDA9116/9118
Содержание A70PF
Страница 1: ...A70PF RX 777NS 1 33 A70PF Service Manual ...
Страница 6: ...A70PF RX 777NS 6 33 D ADJUSTMENT CONTROL LOCATION ...
Страница 10: ...A70PF RX 777NS 10 33 ...
Страница 11: ...A70PF RX 777NS 11 33 ...
Страница 29: ...A70PF RX 777NS 29 33 I EXPLODED DIAGRAM ...
Страница 30: ...A70PF RX 777NS 30 33 J SCHEMATIC DIAGRAM ...
Страница 31: ......
Страница 32: ......
Страница 33: ...A70PF RX 777NS 31 33 K PCB LAYOUT DIAGRAM MAIN BOARD ...
Страница 34: ...A70PF RX 777NS 32 33 CRT BOARD ...
Страница 35: ...A70PF RX 777NS 33 33 MEMO ...