It
is
essential
that
the
End
User
be
made
aware
of
the
O&M
requirements
related
to
the
EAN
ESP
unit.
If
the
red
LED
indicator
light
switches
on
systematically
between
cleaning
regimes
the
cleaning
schedule
should
be
adjusted
accordingly.
8.2.4
As
soon
as
the
red
light
illuminates,
the
unit
cell
needs
to
be
cleaned.
If
the
EAN
ESP
unit
is
not
visible,
AOM
proposes
a
remote
indicator
that
can
be
installed
in
the
kitchen
and
linked
to
the
EAN
units.
8.2.5
When
cleaning
the
AOM
equipment,
do
not
use
caustic
chemical.
The
chemical
could
damage
the
aluminium
ESP
cell.
8.3
Troubleshooting
Note:
All
trouble
shooting
should
be
performed
by
qualified
personel
and
extreme
caution
should
be
used
when
working
on
the
EAN
ESP
unit
electrical
boards.
Problem:
The
EAN
ESP
unit
does
not
power
ON
(no
green
LED
light/
no
voltage)
Have
the
electrical
connections
including
the
fan
interlock
been
done
as
per
AOM
specifications?
Check
240
V
power
reaches
the
unit
when
the
fan
is
switched
ON
If
240
V
power
reaches
the
unit,
is
the
fuse
continuity
on
the
PCD
assured
(red
light
on
the
PCB)?
If
not,
replace
the
fuse
If
yes,
the
issue
is
with
the
PCB
which
is
faulty
and
needs
to
be
replaced.
Problem:
The
EAN
ESP
unit
powers
ON
but
the
amperage
fluctuates
and
does
not
settle
to
a
fixed
amount
Has
the
unit
been
properly
cleaned
and/or
is
the
red
LED
light
showing
on
the
door?
The
EAN
ESP
unit
needs
to
be
cleaned
as
the
buildup
of
grease
and
other
contaminants
has
affected
the
electrical
connections
of
the
unit.
Have
the
cells
been
removed
and
replaced
within
the
unit?
If
yes,
the
connections
between
the
EAN
unit
and
the
cell,
as
well
as
between
the
cells
need
to
be
checked
as
follows:
‐
The
EAN
ESP
unit
insulators
situated
on
the
door
are
free
from
grease
‐
The
cells
are
equipped
with
the
required
springs
and
gaskets
and
all
the
connections
are
ensured.
Problem:
The
EAN
ESP
unit
powers
ON
but
the
amperage
fluctuates
and
does
not
settle
to
a
fixed
amount
–
an
electrical
discharge
can
also
be
heard
within
the
unit.
Have
the
cells
been
removed
and
replaced
within
the
unit?
If
yes,
the
cells
need
to
be
checked
for
any
visible
damage,
particularly
in
the
case
where
aluminimum
plates
are
bent
and
touching.
Has
a
cell
been
damaged?
If
yes,
attempt
to
fix
any
mechanical
damage
to
the
cells
or
replace
the
cell
with
another
clean
cell.
Problem:
The
EAN
ESP
unit
powers
ON
but
no
amperage
is
shown
on
the
amperemeter
Was
this
observed
before
or
after
the
changeover
of
electrostatic
cells?
If
after,
one
of
the
cells
has
a
fault.
Remove
the
cells
and
review
the
cells
including
checking
that
the
the
high
voltage
wires
are
all
attached.