AOM EAN Скачать руководство пользователя страница 18

 

 

 
 

AOM

 

AUSTRALIA

 

21/54

 

Beach

 

Street

 

Kogarah

 

NSW

 

2217

     

Tel

 

Sales

 

1300

 

903

 

788

     

Service

 

1300

 

904

 

088

 

www.aomaus.com.au

    

email

 

[email protected]

 

rev

 

1,

 

22/09/2016

 

 

 

 

18

 

 
 
 

 

It

 

is

 

essential

 

that

 

the

 

End

 

User

 

be

 

made

 

aware

 

of

 

the

 

O&M

 

requirements

 

related

 

to

 

the

 

EAN

 

ESP

 

unit.

  

 

If

 

the

 

red

 

LED

 

indicator

 

light

 

switches

 

on

 

systematically

 

between

 

cleaning

 

regimes

 

the

 

cleaning

 

schedule

 

should

 

be

 

adjusted

 

accordingly.

 

 

  

 

8.2.4

 

As

 

soon

 

as

 

the

 

red

 

light

 

illuminates,

 

the

 

unit

 

cell

 

needs

 

to

 

be

 

cleaned.

 

If

 

the

 

EAN

 

ESP

 

unit

 

is

 

not

 

visible,

 

AOM

 

proposes

 

a

 

remote

 

indicator

 

that

 

can

 

be

 

installed

 

in

 

the

 

kitchen

 

and

 

linked

 

to

 

the

 

EAN

 

units.

  

8.2.5

 

When

 

cleaning

 

the

 

AOM

 

equipment,

 

do

 

not

 

use

 

caustic

 

chemical.

 

The

 

chemical

 

could

 

damage

 

the

 

aluminium

 

ESP

 

cell.

 

 

8.3

 

Troubleshooting

 

 
 

Note:

 

All

 

trouble

 

shooting

 

should

 

be

 

performed

 

by

 

qualified

 

personel

 

and

 

extreme

 

caution

 

should

 

be

 

used

 

when

 

working

 

on

 

the

 

EAN

 

ESP

 

unit

 

electrical

 

boards.

 

 
 
 

Problem:

 

The

 

EAN

 

ESP

 

unit

 

does

 

not

 

power

 

ON

 

(no

 

green

 

LED

 

light/

 

no

 

voltage)

 

Have

 

the

 

electrical

 

connections

 

including

 

the

 

fan

 

interlock

 

been

 

done

 

as

 

per

 

AOM

 

specifications?

 

Check

 

240

 

V

 

power

 

reaches

 

the

 

unit

 

when

 

the

 

fan

 

is

 

switched

 

ON

 

If

 

240

 

V

 

power

 

reaches

 

the

 

unit,

 

is

 

the

 

fuse

 

continuity

 

on

 

the

 

PCD

 

assured

 

(red

 

light

 

on

 

the

 

PCB)?

 

If

 

not,

 

replace

 

the

 

fuse

 

If

 

yes,

 

the

 

issue

 

is

 

with

 

the

 

PCB

 

which

 

is

 

faulty

 

and

 

needs

 

to

 

be

 

replaced.

  

Problem:

 

The

 

EAN

 

ESP

 

unit

 

powers

 

ON

 

but

 

the

 

amperage

 

fluctuates

 

and

 

does

 

not

 

settle

 

to

 

a

 

fixed

 

amount

 

Has

 

the

 

unit

 

been

 

properly

 

cleaned

 

and/or

 

is

 

the

 

red

 

LED

 

light

 

showing

 

on

 

the

 

door?

 

The

 

EAN

 

ESP

 

unit

 

needs

 

to

 

be

 

cleaned

 

as

 

the

 

buildup

 

of

 

grease

 

and

 

other

 

contaminants

 

has

 

affected

 

the

 

electrical

 

connections

 

of

 

the

 

unit.

 

Have

 

the

 

cells

 

been

 

removed

 

and

 

replaced

 

within

 

the

 

unit?

 

If

 

yes,

 

the

 

connections

 

between

 

the

 

EAN

 

unit

 

and

 

the

 

cell,

 

as

 

well

 

as

 

between

 

the

 

cells

 

need

 

to

 

be

 

checked

 

as

 

follows:

  

 

The

 

EAN

 

ESP

 

unit

 

insulators

 

situated

 

on

 

the

 

door

 

are

 

free

 

from

 

grease

 

 

The

 

cells

 

are

 

equipped

 

with

 

the

 

required

 

springs

 

and

 

gaskets

 

and

 

all

 

the

 

connections

 

are

 

ensured.

  

Problem:

 

The

 

EAN

 

ESP

 

unit

 

powers

 

ON

 

but

 

the

 

amperage

 

fluctuates

 

and

 

does

 

not

 

settle

 

to

 

a

 

fixed

 

amount

 

 

an

 

electrical

 

discharge

 

can

 

also

 

be

 

heard

 

within

 

the

 

unit.

  

Have

 

the

 

cells

 

been

 

removed

 

and

 

replaced

 

within

 

the

 

unit?

 

If

 

yes,

 

the

 

cells

 

need

 

to

 

be

 

checked

 

for

 

any

 

visible

 

damage,

 

particularly

 

in

 

the

 

case

 

where

 

aluminimum

 

plates

 

are

 

bent

 

and

 

touching.

   

Has

 

a

 

cell

 

been

 

damaged?

 

If

 

yes,

 

attempt

 

to

 

fix

 

any

 

mechanical

 

damage

 

to

 

the

 

cells

 

or

 

replace

 

the

 

cell

 

with

 

another

 

clean

 

cell.

  

Problem:

 

The

 

EAN

 

ESP

 

unit

 

powers

 

ON

 

but

 

no

 

amperage

 

is

 

shown

 

on

 

the

 

amperemeter

 

Was

 

this

 

observed

 

before

 

or

 

after

 

the

 

changeover

 

of

 

electrostatic

 

cells?

  

If

 

after,

 

one

 

of

 

the

 

cells

 

has

 

a

 

fault.

 

Remove

 

the

 

cells

 

and

 

review

 

the

 

cells

 

including

 

checking

 

that

 

the

 

the

 

high

 

voltage

 

wires

 

are

 

all

 

attached.

  

Содержание EAN

Страница 1: ...7 INSTALLATION GUIDELINES 11 7 1 General 11 7 2 Delivery and handover 12 7 3 Receiving 12 7 4 Unpacking 12 7 5 Storage 12 7 6 Installation scenarios 13 7 7 Installation 13 7 8 Access requirements 14 7...

Страница 2: ...out Australia and New Zealand Please contact your AOM representative for project examples The EAN models available are EAN 200 EAN 400 EAN 600 EAN 660 T EAN 800 and EAN 1200 More detailed specificatio...

Страница 3: ...1340 W x 480 H Number of cells mm 1 cell 1 cell 2 cells 3 cells Size of cells mm 470 L x 325 W x 465 H 300 L x 700 W x 455 H 470 L x 325 W x 465 H 470 L x 325 W x 465 H Housing Material Powder Coated...

Страница 4: ...AOM AUSTRALIA 21 54 Beach Street Kogarah NSW 2217 Tel Sales 1300 903 788 Service 1300 904 088 www aomaus com au email info aomaus com au rev 1 22 09 2016 4 3 DIMENSIONS 3 1 EAN 200...

Страница 5: ...AOM AUSTRALIA 21 54 Beach Street Kogarah NSW 2217 Tel Sales 1300 903 788 Service 1300 904 088 www aomaus com au email info aomaus com au rev 1 22 09 2016 5 3 2 EAN 300...

Страница 6: ...AOM AUSTRALIA 21 54 Beach Street Kogarah NSW 2217 Tel Sales 1300 903 788 Service 1300 904 088 www aomaus com au email info aomaus com au rev 1 22 09 2016 6 3 3 EAN400...

Страница 7: ...AOM AUSTRALIA 21 54 Beach Street Kogarah NSW 2217 Tel Sales 1300 903 788 Service 1300 904 088 www aomaus com au email info aomaus com au rev 1 22 09 2016 7 3 4 EAN600...

Страница 8: ...AOM AUSTRALIA 21 54 Beach Street Kogarah NSW 2217 Tel Sales 1300 903 788 Service 1300 904 088 www aomaus com au email info aomaus com au rev 1 22 09 2016 8 4 COMPONENTS 4 1 1 Schematic diagrams...

Страница 9: ...comb Filters which have been tested to meet the requirements of AS1668 2 2012 section E5 regarding not deemed combustible material in accordance with section AS1530 1 The filters have also been tested...

Страница 10: ...eceived by the unit o Amperemeter indicating the consumed amperage of the unit see below for the recommended amperage values o ON OFF switch and indicator lights Green LED light indicates unit is on R...

Страница 11: ...al Protection Bureau standard Testing was carried out on Chinese cooking type oil smoke as a testing sample at different speeds through the filter equivalent to a heavy Type 4 cooking Filtration effic...

Страница 12: ...ms are accounted for by referencing the delivery receipt or packing list 7 3 2 Inspect each crate or carton for shipping damage before accepting delivery Alert the carrier of any damage detected The c...

Страница 13: ...Electrostatic Precipitator will ensure high efficiency filtration of smoke and grease particles To maximise the unit s capacity it is recommended to place the units as close as possible to the kitche...

Страница 14: ...haust fan is running 7 7 10 The EAN ESP unit can be installed outside on roof tops along outside duct runs etc however the unit s electrical console needs to be covered by a weather proof box 7 8 Acce...

Страница 15: ...e that a safe working platform can be installed in order to service the units 7 8 9 EAN ESP unit installed in a plant room An access path from the plantroom entry point to the EAN ESP unit door of a m...

Страница 16: ...m test prior to dispatch of the equipment meaning that the EAN ESP unit can be plugged in and used immediately 7 12 Powering the unit ON 7 12 1 Press the switch ON OFF to ON The red LED light will swi...

Страница 17: ...chase if an AOM cleaning contract is signed It is essential that the end user be made aware of this requirement 8 2 1 Cleaning and periodic maintenance is vital to ensure optimal performance of the AO...

Страница 18: ...PCB which is faulty and needs to be replaced Problem The EAN ESP unit powers ON but the amperage fluctuates and does not settle to a fixed amount Has the unit been properly cleaned and or is the red L...

Страница 19: ...date of dispatch 9 1 5 A spare part is warranted to be free from defects and or workmanship for a period of ninety 90 days from the date of dispatch 9 1 6 If a client is not able to prove that the equ...

Страница 20: ...tic cells for cleaning 1 7 Remove the grease tray Discharge grease into the available grease trap Clean and replace the grease tray 1 8 Clean the cell guides throughout the whole EAN unit where the el...