2. The motor’s drive IC on the PCB might be out of condition.
D. The lamp is cutting out intermittently
1. The lamp is not working well. Check the mains voltage either too high or too low.
2. Internal temperature may be too high. Check if replacement of fan is needed on the head.
E. If The pan belt is broken
1. Turn off the mains power.
2. Loosen the screws (A)
,
open the cover(B).
3. Loosen the motor gear (C).
4. Loosen the screws (D)
5. Unplug all the connect wires over the belt.
6. Change a new belt (E), put the belt around the axis gear and motor gear.
7. Plug all the connect wires back upon the belt.
8. Tighten all the screws.
F. If The tilt belt is broken
1. Turn off the mains power.
2. Loosen all the screws (A) and open the right arm cover (B).
3. Loosen the screws (C) that fix the bridge.
4. Change a new belt (D). Please adjust the tension of the belt properly. Note: do not fix the belt too
tight as it is can easily rupture.
5. Reverse the procedures from step 3 to 2.
8. Maintenance and Cleaning
Maintenance:
A. As the pictures shown above, please replace the cabl
e or cable joints immediately once they’ve
turned yellow.
B. Do maintain the fixtures every two months and make sure that all the screws and terminals have
been locked firmly to make sure the normal performance of the fixtures. Negligence of
maintenance would cause malfunction of the fixture.
Cleaning:
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically
to optimize light output. Cleaning frequency depends on the environment in which the fixture
operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on
the
11/12