9. White- Balance, Luminance Adjustment
Approximately 30 minutes should be allowed for warm up before proceeding white balance adjustment.
Before started adjust white balance , please set the Chroma-7120 MEM Channel 3 to Warm (6500K) color, MEM
Channel 4 to Normal (7300K) color, MEM Channel 9 to Cool (9300K) color , and MEM Channel 10 to sRGB color
( our Warm color parameter is x = 313 ±30, y = 329 ±30, Y>140cd/m
2
; Normal color parameter is x = 302 ±30, y =
318 ±30, Y>130cd/m
2
; Cool color parameter is x = 283 ±30, y = 297 ±30, Y>110cd/m
2
; sRGB color parameter is x
= 313 ±30, y = 329 ±30, Y>140cd/m
2
)
How to setting MEM channel you can reference to chroma 7120 user guide or simple
use “ SC” key and
“ NEXT” Key
to modify xyY value and use “ID” key to modify the TEXT
description Following is the procedure
to do white-balance adjust .
2. Setting the color temp. you want
A. MEM.CHANNEL 3 (Warm color):
Warm color temp. parameter is x = 313 ±30, y = 329 ±30, Y>140cd/m
2
B. MEM.CHANNEL 4 (Normal color):
Normal color temp. parameter is x = 302 ±30, y = 318 ±30, Y>130cd/m
2
C. MEM.CHANNEL 9 (Cool color):
Cool color temp. parameter is x = 283 ±30, y = 297 ±30, Y>110cd/m
2
D. MEM.CHANNEL 10 (sRGB color):
sRGB color temp. parameter is x = 313 ±30, y = 329 ±30, Y>140cd/m
2
3. Into Factory mode of AOC 1619Swa:
Press the MENU button, pull out the power cord, and then plug the power cord. Then the factory OSD will be at the
left top of the panel.
4. Bias adjustment:
Set the
Contrast
to 50; Adjust the
Brightness
to 80.
5. Gain adjustment:
Move cursor to “-F-” and press MENU key
A. Adjust Warm (6500K) color-temperature
1. Switch the chroma-7120 to
RGB-Mode
(with press “MODE” button)
2. Switch the MEM.channel to Channel 3 (with up or down arrow on chroma 7120)
3. The LCD-indicator on chroma 7120 will show x = 313 ±30, y = 329 ±30, Y>140cd/m
2
4. Adjust the RED on factory window until chroma 7120 indicator reached the value R=100
5. Adjust the GREEN on factory window until chroma 7120 indicator reachedthe value G=100
6. Adjust the BLUE on factory window until chroma 7120 indicator reached the value B=100
7. Repeat above procedure (item 4, 5, 6) until chroma 7120 RGB value meet the tolerance =100±2
B. Adjust Normal (7300K) color-temperature
1. Switch the chroma-7120 to
RGB-Mode
(with press “MODE” button)
2. Switch the MEM.channel to Channel 4(with up or down arrow on chroma 7120)
3. The LCD-indicator on chroma 7120 will show x = 302 ±30, y = 318 ±30, Y>130cd/m
2
4. Adjust the RED on factory window until chroma 7120 indicator reached the value R=100
Содержание 1619Swa
Страница 25: ...15 6 LCD Color Monitor AOC 1619Swa 25 6 2 Power Board...
Страница 26: ...15 6 LCD Color Monitor AOC 1619Swa 26...
Страница 27: ...15 6 LCD Color Monitor AOC 1619Swa 27 6 3 Key Board...
Страница 28: ...15 6 LCD Color Monitor AOC 1619Swa 28 7 PCB Layout 7 1 Main Board...
Страница 29: ...15 6 LCD Color Monitor AOC 1619Swa 29...
Страница 30: ...15 6 LCD Color Monitor AOC 1619Swa 30 7 2 Power Board...
Страница 31: ...15 6 LCD Color Monitor AOC 1619Swa 31 7 3 Key Board...
Страница 41: ...15 6 LCD Color Monitor AOC 1619Swa 41 10 Monitor Exploded View...