-L*F1011 8/11-
0
1
0
1
■
Changing the threshold setting
■
Light receiving level indication setting
■
Light emitting power setting
■
ON Delay setting
■
OFF Delay setting
■
One Shot setting
■
Changing the hysteresis setting
■
Alarm Hi setting
■
Alarm monitoring time setting
■
Light ON / Dark ON setting
■
Operation mode change enable/disable setting
This parameter specifies a threshold of light receiving level for
judgment of detection status.
In the case of “Parameter 8 Variable 0: AD value indication”
A threshold setting is indicated in the range of 0 to 4095.
In the case of “Parameter 8 Variable 1: 0-100% indication”
A threshold setting is indicated in the range of 0 to 100%.
(0% and 100% are the minimum and maximum AD values
registered by teaching, respectively.)
This parameter specifies the light receiving level indication mode.
Sensing levels of parameter 01, 02, 03 and 04 are automatically converted into
AD value or 0-100%, depending on the setting of this parameter.
This parameter specifies a change in light receiving quantity required to turn
the detection status from ON to OFF.
This parameter specifies a light emitting level.
This parameter specifies an ON delay time.
This parameter specifies an OFF delay time.
This parameter specifies a one-shot time.
Fiber side
Transmission side
ON/OFF threshold display (green)
In the case of “Parameter 8 Variable 0: AD value indication”
An AD-converted light receiving level is indicated in the
range of 0 to 4095.
In the case of “Parameter 8 Variable 1: 0-100% indication”
A light receiving level is indicated in the range of 0 to 100%.
(0% and 100% are the minimum and maximum AD values
registered by teaching, respectively.)
Light receiving level display (red)
[7-segment display]
*
The difference in detection status registered by teaching is defined as 100%.
*
The setting range depends on the setting of parameter 8.
This parameter specifies an upper limit value for alarm judgment.
*
Make sure that Alarm Hi setting is larger than Alarm Lo setting.
AD value
- Address Writer (ARW-04): Parameter 01
- Address Writer (ARW-04): Parameter 08
- Address Writer (ARW-04): Parameter 09
- Address Writer (ARW-04): Parameter 10
- Address Writer (ARW-04): Parameter 11
- Address Writer (ARW-04): Parameter 12
- Address Writer (ARW-04): Parameter 02
- Address Writer (ARW-04): Parameter 03
- Address Writer (ARW-04): Parameter 04
- Address Writer (ARW-04): Parameter 05
- Address Writer (ARW-04): Parameter 06
- Address Writer (ARW-04): Parameter 07
Factory setting: 50 (AD value)
0-4095
0-100%
0-100%
AD value
Factory setting: 5 (AD value)
0-4095
0-100%
0-100%
AD value
Factory setting: 0 (AD value)
0-4095
0-100%
0-100%
AD value
Factory setting: 0 (AD value)
0-4095
0-100%
0-100%
Variable
Factory setting: 50
Factory setting: 0
Factory setting: 0
Factory setting: 0
Factory setting: 0
Factory setting: 0
Factory setting: 0
Factory setting: 0
Unit
Description
Through-beam type, Dark (interrupt) ON
Through-beam type, Light (transmit) ON
Reflection type, Dark (no reflection) ON
Reflection type, Light (reflection) ON
Disabled (Simplified mode)
Enabled (Normal mode)
■
Alarm Lo setting
This parameter specifies a lower limit value for alarm judgment.
This parameter specifies a monitoring time for alarm judgment.
This parameter specifies the Light ON or Dark ON mode.
This parameter specifies whether the diagnosis function is enabled or disabled.
*
Make sure that Alarm Hi setting is larger than Alarm Lo setting.
Variable
Description
AD value indication (0-4095 Digit)
0-100% indication
Variable
Description
Variable
Description
Variable
Description
Variable
Description
Variable
Description
Variable
3-255
100ms
0
1
2
3
*
Once a set value is changed by rewriting from the host, the values of
parameters 01, 02, 03 and 04 will not be automatically converted.
0
1
2
High
Low
Middle
0-999
100ms
0-999
100ms
0-999
100ms
Parameter setting