background image

Note on use

ASLINKAMP [Fiber Amplifier (with 7-segment Display)]

L

-F1011

LA-F1011
LB-F1011

LINK

IN

ALM

LINK

IN

ALM

-L*F1011  1/11-

Fiber amplifier 
(with 7-segment display)

Bit operation 

○ 

System Safety

This system is intended for general industrial applications. It 

does not have functions for supporting applications requiring 

higher levels of safety such as safety-related devices or 

accident prevention systems. The product must not be used 

for these purposes.

○ 

Always turn off the power in installing or replacing the system.

○ 

Prolonged continuous flow of a rated load current or higher or 

a transit current due to load short-circuit, etc., in the hybrid 

unit including the output unit and the output circuit may result 

in smoking or firing. An external safety device such as a fuse 

must be installed.

○ 

System power supply

Use a stable, 24V DC power supply. Use of an unstable 

power supply may cause problems with the system.

○ 

Separately route high-voltage and power cables

Although the AnyWireASLINK has a high noise margin, install 

the transmission line and I/O cables away from high-voltage 

and power cables.

○ 

Connectors and terminals

- Consider the length and securing method of cables so that 

the cables and connectors would not be subjected to any 

stress and, even if they are under stress, they would not 

become loose.

- Make sure to prevent any metal objects from getting inside 

the connectors or the terminal blocks.

- Short-circuits caused by metal objects or mis-wiring are 

likely to damage the device.

○ 

Do not impose any external loads on the units. Doing so may 

cause a failure.

○ 

Do not disconnect or reconnect between the transmission

line and slave units when the transmission line is active. A 

malfunction may occur.

○ 

Use the AnyWireASLINK within the range of the specifications 

and conditions shown below.

[Type]

[Warranty]

[Functions]

[Included in the Package]

[Name of Each Part]

[Notes on Safety]

AnyWireASLINK System Products Guide

■ 

Warranty period

The warranty on the delivered Product shall continue to be effective for one (1) year 

after the delivery thereof to a location as designated by the original owner.

■ 

Scope of warranty

Should a defect occur in any part of the Product during the foregoing warranty 

period when it is used normally in accordance with the specifications described in 

this Products Guide, the Company shall replace or repair the defect free of charge, 

except when it arises as a result of:
[1] Misuse or abuse of the Product by the owner;
[2] Fault caused by other than the delivered Product;
[3] The unauthorized modification or repair of the Product by any person other than 

the Company’s personnel;

[4] Any unusual force of nature, disaster or other cause beyond the Company’s 

control.

The term “warranty,” as used herein, refers to the warranty applicable to the 

delivered product alone. The Company shall not be liable for consequential or 

incidental damages resulting from any malfunction.

■ 

Repair at cost

After the expiration of the warranty period, the owner shall be responsible for all 

costs and expenses incurred for the troubleshooting and repair of the Product. 

Even during the warranty term, the Company shall repair any defects arising from 

causes other than within the scope of the warranty as specified above, at the 

owner’s cost.

■ 

Changes in the product specifications and the descriptions in the manual

The descriptions in this manual may be subject to change without notice.

For setting addresses and other parameters, ARW-04 (Ver. 04-1.01 or later version) is 
required. Prepare the Address Writer separately.

Precautions that must be observed in order to use this system safely are indicated as 
shown below. You must observe these precautions.

A WARNING indicates a potentially hazardous situation which, if not 

handled correctly, could result in death or serious injury.

A CAUTION indicates a potentially hazardous situation which, if not 

handled correctly, may result in personal injury or property damage.

CAUTION

WARNING

WARNING

CAUTION

1CH (Master unit)
1CH (Slave unit)

ASLINKAMP 4-wire type (isolated)

General-purpose fiber unit
Sensitivity adjustment (threshold) 
Hysteresis 
Light ON/Dark ON
Light receiving level indication changeover 
Light emitting power 
Delay timer 
One-shot 
Automatic address/parameter setting
7-segment display orientation 
Sensing level drop
Slave unit voltage drop

Model

Unit to connect

(example)

Features

LA-F1011 (Master)
LB-F1011 (Slave)

Amplifier body ... 1
Amplifier body ... 1

Master

Slave

Expansion connector

Transmission line

LED indicators

Protective cover

7-segment display

LED indicators

Protective cover

7-segment display

Содержание ASLINKAMP L F1011 Series

Страница 1: ...the foregoing warranty period when it is used normally in accordance with the specifications described in this Products Guide the Company shall replace or repair the defect free of charge except when...

Страница 2: ...size and length of the transmission line and the allowable supply current lie within an appropriate range Example of mixed installation with 2 wire non isolated and 4 wire isolated terminals To connec...

Страница 3: ...than 50m 4 wire terminal 4 wire terminal 4 wire terminal 4 wire terminal 4 wire terminal 24V DC stabilized power supply General purpose power supply filter Use it if necessary Filter representation i...

Страница 4: ...to the entire system If the total length of the section where all the DP DN 24V and 0V lines run in parallel is more than 50m When using this filter please be careful of the positions of LOAD and LINE...

Страница 5: ...ases flammable gases and sulfur Locations far from high voltage or high current cables Locations far from servos inverters and other cables and controllers that generate high frequency noise Expansion...

Страница 6: ...ing method Direct connection Connection via attachment E39 F9 Fiber diameter mm Power supply to the entire system DP Red DN Black 24V Green 0V White DP Red DN Black 24V Green 0V White 1 2 3 4 DN DP 0V...

Страница 7: ...n signal DP DN and power supply 24V 0V being connected set parameters with the address writer 2 This setting procedure is required for all terminals After opening the protective cover of the terminal...

Страница 8: ...100 The setting range depends on the setting of parameter 8 This parameter specifies an upper limit value for alarm judgment Make sure that Alarm Hi setting is larger than Alarm Lo setting AD value A...

Страница 9: ...ransmission line between the ASLINKAMP and the master unit shorter Assign an address other than 255 The address of ASLINKAMP remains to be 255 factory setting The address of ASLINKAMP is duplicated Th...

Страница 10: ...ting for master unit only Light receiving level setting for detection judgment Light receiving level alarm upper limit setting Light receiving level alarm lower limit setting Light receiving level ala...

Страница 11: ...19 2020 UMA 12100AF EN L F1011 11 11 Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by website http www anywire jp O...

Отзывы: