BL2109-0

-22

Branching Unit (IP67)

AnyWireASLINK System Products Guide

Function List

[Type]

-

BL21090*22

  1/8-

BL2109-08-22

8 ports

BL2109-04-22

4 ports

4 ports
8 ports

IP67

is a registered trademark of OMRON Corporation.

This 

Products Guide

 is a document that describes individual products. Read it carefully to understand the products.

Product

Specifications Waterproof

Branching unit with M12 
Smartclick connector

[Notes on Safety]

Precautions that must be observed in order to use this system safely are indicated as shown below. 

You must observe these precautions.

[Warranty]

WARNING

CAUTION

 

WARNING



 

CAUTION

A WARNING indicates a potentially hazardous 
situation which, if not handled correctly, could 
result in death or serious injury.

System Safety
This system is intended for general industrial applications. It does not have functions for supporting applications requiring higher levels 
of safety such as safety-related devices or accident prevention systems. The product must not be used for these purposes.
Always turn off the power in installing or replacing the system.
Prolonged continuous flow of a rated load current or higher or a transit current due to load short-circuit, etc., in the hybrid unit including 
the output unit and the output circuit may result in smoking or firing. An external safety device such as a fuse must be installed.

System power supply
Use a stable, 24V DC power supply. Use of an unstable power supply may cause problems with the system.
Separately route high-voltage and power cables
Although the AnyWireASLINK has a high noise margin, install the transmission line and I/O cables away from high-voltage and power 
cables.
Connectors and terminals

- Pay careful attention to the length and installation of cable wiring to ensure that connectors and cables are neither overloaded nor disconnected.
- Make sure to prevent any metal objects from getting inside the connectors or the terminal blocks.
- Short-circuits caused by metal objects or mis-wiring are likely to damage the device.

Do not impose any external loads on the units. Doing so may cause a failure.
Do not disconnect or reconnect between the transmission line and slave units when the transmission line is active. A malfunction may occur.
Use the AnyWireASLINK within the range of the specifications and conditions shown below.

Warranty period

The warranty on the delivered Product shall continue to be effective for one (1) year after the delivery thereof to a location as designated by 

the original owner.

Scope of warranty

Should a defect occur in any part of the Product during the foregoing warranty period when it is used normally in accordance with the 

specifications described in this Products Guide, the Company shall replace or repair the defect free of charge, except when it arises as a result of:

[1] Misuse or abuse of the Product by the owner;

[2] Fault caused by other than the delivered Product;

[3] The unauthorized modification or repair of the Product by any person other than the Company’s personnel;

[4] Any unusual force of nature, disaster or other cause beyond the Company’s control.

The term “warranty,” as used herein, refers to the warranty applicable to the delivered product alone. The Company shall not be liable for 

consequential or incidental damages resulting from any malfunction.

Repair at cost

After the expiration of the warranty period, the owner shall be responsible for all costs and expenses incurred for the troubleshooting and 

repair of the Product. Even during the warranty term, the Company shall repair any defects arising from causes other than within the scope 

of the warranty as specified above, at the owner’s cost.

A CAUTION indicates a potentially hazardous situation 
which, if not handled correctly, may result in personal 
injury or property damage.

Содержание ASLINK BL2109-0 Series

Страница 1: ...e neither overloaded nor disconnected Make sure to prevent any metal objects from getting inside the connectors or the terminal blocks Short circuits caused by metal objects or mis wiring are likely t...

Страница 2: ...wer supply is also possible Make sure to use a four wire isolated terminal in the case of input and load driving using an external power supply Black DN Red DP Brown White Black DN Red DP AnyWireASLIN...

Страница 3: ...V DP 0V DN 1 2 4 3 UL style 2464 VVC AWG16 4C 8 2 Black IP67LK CAB 13252A UL style 2464 VVC AWG16 4C 8 2 Black IP67LK CAB 13252A XS5H XS5H M4 screw hole 2 M4 screw hole 2 M4 screw hole 2 M4 screw hole...

Страница 4: ...22 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 4 3 2 1 1 2 3 4 1 2 3 4 24V DP 0V DN 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 8 7 6 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 4 3 2 1 1 2 3 4 1 2 3 4 24V DP...

Страница 5: ...the atmospheric pressure at an altitude of 0 meters Doing so may result in malfunction 2 Pollution level is an index that indicates the degree of occurrence of conductive substances in the environment...

Страница 6: ...5 50 25 5 20 1 2 3 4 24V DP 0V DN 1 2 4 3 4 1 2 3 A B BL2109 04 22 1 2 3 4 24V DP 0V DN AWG16 8 2 42 33 9 4 2 73 9 countersink depth 11 2 R2 25 Lot No label 4 5 drilling Unit mm Arrow A view Arrow B...

Страница 7: ...109 08 22 Lot No label 1000 135 5 50 25 5 20 1 2 3 4 24V DP 0V DN 1 2 4 3 4 1 2 3 A Arrow A view Arrow B view B 1 2 3 4 24V DP 0V DN AWG16 8 2 42 33 9 4 2 2 R2 25 77 3 34 2 9 countersink depth 11 2 4...

Страница 8: ...Japan 2017 UMA 17798B EN BL21090 22 8 8 Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by website http www anywire...

Отзывы: