Содержание PA-VIII1-C-FA

Страница 1: ...ANYWAVE PA VIII1 C FA User Manual Version 1 0 June 25 2018...

Страница 2: ...ssumed for its use The manufacturer makes no representations or warranties either expressed or implied by or with respect to anything in this manual and shall not be liable for any implied warranties...

Страница 3: ...e required from Anywave for all equipment returns Please direct all return inquiries to the Anywave Service Department at support_us anywavecom com providing the Sales Order number and Serial Number s...

Страница 4: ...ded as a general guide for trained and qualified personnel well aware of the dangers inherent in handling potentially hazardous electrical transmission equipment The installation operation maintenance...

Страница 5: ...ance 6 1 1 Front Panel 6 1 2 Back Panel 8 2 Specifications 9 3 Control Interface 10 3 1 Local Exciter Interface 10 3 2 Web Interface 12 3 3 Local Touch Screen User Interface 15 3 3 1 Home Screen 15 3...

Страница 6: ...er supply is turned off or internal power supply module does not work LED_RS485 Green light will flash once per second when the internal communication is normal Green light will stay constantly on or...

Страница 7: ...e air intake path No screw driver is needed and no disassembly of the PA is required 2 When a warning occurs and the PA enters auto protection mode the only way to clear this state is to cycle power o...

Страница 8: ...or the output power is higher than preset FWD threshold it may trigger the current limiting function The PA will enter the auto protection mode and there will be reduced RF output or even no RF output...

Страница 9: ...1 5 Shoulder Level 36dBc with pre correction ON Size 480mm W 222mm H 423mm L Note 1 The electrical interface characteristics are measured at rated power Values may change 2 Operating in abnormal cond...

Страница 10: ...ter D9 REMOTE RS232 port With this connection established all the PA information will be displayed in the PAC sub menu in the advanced menu of ACT 5X exciter as shown below Note The displayed settings...

Страница 11: ...PA U01 C FA User Manual ACT PAVIII1 USR DOC V1 0 06 25 2018 Page 11 of 27...

Страница 12: ...Enter the IP address of the PA the default value is 192 168 1 210 in a web browser s address bar to cause a login window to pop up The admin tier provides full status and control of the PA and is acce...

Страница 13: ...PA U01 C FA User Manual ACT PAVIII1 USR DOC V1 0 06 25 2018 Page 13 of 27...

Страница 14: ...the alarm s and restart the unit And check again to see if the alarm is gone and the unit is out of protection mode Important unit entering auto protection mode may be at reduced power for protection...

Страница 15: ...II1 USR DOC V1 0 06 25 2018 Page 15 of 27 3 3 Local Touch Screen User Interface 3 3 1 Home Screen Turn on the power supply and the PA enters the initialization process and after 5 seconds the PA enter...

Страница 16: ...N OFF control When GREEN as shown above this indicates the TX is ON When RED this indicates the TX is OFF FWD Forward Power Meter Touching the white display box of FWD will toggle its display units be...

Страница 17: ...output signal a the same time and the PA is considered linked with an exciter when the PA detects an RF output present from the exciter as monitored Auto Exciter Switchover In a Dual Drive configurati...

Страница 18: ...R DOC V1 0 06 25 2018 Page 18 of 27 If the manual switching is successful a window will pop up indicating Change succeed as shown below If the manual switching is not successful a window will pop up i...

Страница 19: ...an RS 485 addess ID of 80H as found under the Exciter CONFIG submenu corresponding with Exciter A In a dual drive TX Exciter B will be configured with an RS 485 ID of 81H Pressing the Exciter A or Ex...

Страница 20: ...reen as shown below The Config Screen has two functional sections on the right Press any of these buttons to navigate to that config screen The Network screen is used to configure all the TX networkin...

Страница 21: ...bar in this screen Pressing the Set button will lead to the corresponding configuration screen of IP or Mask or GateWay accordingly Using the IP setting as example Press any part of the white bar on...

Страница 22: ...PA U01 C FA User Manual ACT PAVIII1 USR DOC V1 0 06 25 2018 Page 22 of 27...

Страница 23: ...al ACT PAVIII1 USR DOC V1 0 06 25 2018 Page 23 of 27 AGC Screen This screen is used to set the AGC Reference output power of the PA and to turn the PA AGC ON OFF Press the AGC button to turn AGC ON bu...

Страница 24: ...PA U01 C FA User Manual ACT PAVIII1 USR DOC V1 0 06 25 2018 Page 24 of 27...

Страница 25: ...lifier icon on the Home page will navigate to the Amplifier Status Screens Temp Temperature of the amplifier V50 Reading of 50 V power supply of the amplifier Cur1 Device current Cur2 5 N A for 60W am...

Страница 26: ...PA U01 C FA User Manual ACT PAVIII1 USR DOC V1 0 06 25 2018 Page 26 of 27 3 3 5 HELP SCREEN...

Страница 27: ...AVIII1 USR DOC V1 0 06 25 2018 Page 27 of 27 Anywave Communication Technologies Inc 300 Knightsbridge Parkway Suite 150 Lincolnshire IL 60069 Tel 847 415 2258 Fax 847 415 2112 Email sales_us anywaveco...