background image

 

 

ACT-5X Exciter User Manual 

Version 3.0 05/07/2015 

 

Page 10 of 26 

 

 

 

3.3 User Menu 

In Control mode, the user may modify configuration settings of the exciter/translator. There are two 

levels of control, the User Menu and the Advanced Menu. To enter the User Menu, press 

both

 the "Left" 

and  "Right"

 

buttons

 

at  the  same  time

  while  in  query  mode.  The  User  Menu  in  control  mode  is  shown 

below in Table 5. In the next section we will present the Advanced Menu. 

Table 5 Main Menu 

Welcome to setting interface! 

*SYSTEM 

RF 

FREQ 

MODE 

CONFIG 

 

The Main User Menu consists of 5 sub-menus: SYSTEM, RF, FREQ, MODE and CONFIG.   

 

Once  at  the  main  menu,  press  the  "Left"  or  "Right"  buttons  to  move  the  cursor  and  navigate  to  the 

desired sub-menu. Once the cursor is positioned just above the desired sub-menu, press the "OK" button to 

enter  the target sub-menu. When  in  the corresponding sub-menu, press "Left" or "Right" button  to  move 

the  cursor  to  the  target  parameter  and  then  press  the  "Up"  or  "Down"  buttons  to  select  different  options 

from  the  drop-down  boxes.  Once  you  have  selected  the  desired  option, 

press  the  "OK"  button  to  apply 

and save, or press the "ESC" button to skip the changes and return to the upper menu. 

 

All the parameters of sub-menus are shown in Tables 6 through Table 10 respectively. 

 

Table 6 System Menu 

 

CTL 

ADPC 

INPUT 

Default 

RMT 

OFF 

TS 

Options 

RMT 

OFF 

TS 

LCA 

UPDATE 

TUNER 

 

HOLD 

 

 

Note:   

1)

 

The  "CTL"  (Control)  setting  has  two  options,  "RMT"  (Remote)  and  "LCA"  (Local).  The 

exciter/translator can be switched between these two modes only via the front panel interface. When 

in  "Local"  mode,  the  exciter/translator  can  only  be  controlled  by  the  front  panel  interface  and  all 

commands  from  serial  port  or  WEB  are  ignored.  When  in  "Remote"  mode,  settings  from  the  front 

panel keyboard are ignored - with the exception of "RMT"/"LCA" setting, and only commands from 

the  remote  control  interface,  such  as  serial  port  or  WEB,  are  processed.  Notice  that  LED  "SysErr" 

remains on all the time in "LCA" mode, and only indicates a SysErr when it is flashing. 

Содержание ACT-5X

Страница 1: ...ANYWAVE ACT 5X ATSC Exciter Translator User Manual Version 3 0 ACT 5XU A C May 7 2015...

Страница 2: ...means without the express written permission of Anywave Communication Technologies Inc Disclaimer Information provided by Anywave Communication Technologies is believed to be accurate and complete ho...

Страница 3: ...eration Specifications 6 3 Menu 8 3 1 Initialization 8 3 2 Query Mode 8 3 3 User Menu 10 3 4 Advanced Menu 15 3 4 Web Interface 19 4 Connection 21 4 1 Connect the Transmitter 21 4 2 Start ADPC functio...

Страница 4: ...mode LED_ TS1 Green light on indicates the synchronization of input RF signal is OK LED_TS2 Green light on indicates the equalization of input RF signal is OK LED_TSErr Red light on indicates there i...

Страница 5: ...n RF signal output N type female nominal 0 dBm output DRYLOOP RS232 Dry loop for remote control REMOTE RS232 Serial port for remote control REMOTE RJ45 B 10M 100M Ethernet for remote control TSoIP RJ4...

Страница 6: ...or BNC female Impedance 50 Level 30 dBm 0 dBm Recommended range 15 dBm 5 dBm Location Back Panel AGC_IN Connector BNC female Impedance 50 DC Voltage 0 V 5 V Location Back Panel RF_OUT Connector N type...

Страница 7: ...fications No Content Unit Value 1 Input Level mv 200 2 Positive Transition 20 80 ps 1200 3 Negative Transition 20 80 ps 1200 4 Deterministic Jitter 10 5 Random Jitter 8 Note 1 The electrical interface...

Страница 8: ...TS_IN_2 and performs a modulation at the specified transmit frequency The first step after turning on the unit is to confirm the desired operating mode Exciter or Translator according to your applicat...

Страница 9: ...R and about 3 seconds to get the first reading of LID and UID After averaging the displayed upper limit on the TSNR is about 39 dB and about 54 DB for the IMD metrics 2 The RSNR and RSSI in Table 3 ar...

Страница 10: ...cursor to the target parameter and then press the Up or Down buttons to select different options from the drop down boxes Once you have selected the desired option press the OK button to apply and sa...

Страница 11: ...mputing coefficients for both the linear and non linear pre correction for the entire transmission system including the distortion of both transmitter and band pass filter This process takes about 8 t...

Страница 12: ...translator system level automatic gain control AGC has options ON and OFF LVL and REF are decimal numbers whose range is from 0 to 255 LVL is the reading of the DC voltage from Port AGC_IN which refle...

Страница 13: ...the FREQ sub menu specifies the channel frequency for the modulated RF output signal of the exciter translator 3 The Hz parameter provides a direct adjustment offset of the frequency of the TXFREQ RF...

Страница 14: ...hich is setup in CONFIG sub menu in a browser s address bar the login interface will pop up and give user prompts to input the user name and password There are two tiers of web interface available The...

Страница 15: ...IG Then press both the Up and Down buttons at the same to enter Advanced Menu as shown below Table 12 Advanced User Menu Welcome to advanced interface AD1 MUTE TX_EX DPD LATCH SN PAC Table 13 through...

Страница 16: ...alf Full the system will NOT DELETE any new coming packets c Bit0 The switch of Program Clock Reference Correction function 1 means PCR function is ON 0 means PCR function is OFF 2 Sw_Up and Sw_Down a...

Страница 17: ...es from 0x0 to 0xF The lower the parameter s value is the harder the reduction of crest factor will be And 0xF means bypass the whole CFR function No reduction at all Note If ADPC Pre correction is on...

Страница 18: ...eading will keep flashing indicating the feedback level may need to be adjusted Table 17 Latch Menu RESET U1 U2 RF GPS TS SYS 1PPS SFN Default OK 0 0 0 0 0 0 0 0 Options OK 0 0 0 0 0 0 0 0 CLR 1 1 1 1...

Страница 19: ...e exciter translator IPaddress 192 168 1 143 will bring up the following login window There are two tiers of web interface available The first guest tier is limited in monitoring and control allowing...

Страница 20: ...ACT 5X Exciter User Manual Version 3 0 05 07 2015 Page 20 of 26 admin web interface...

Страница 21: ...exciter translator s feedback level 30 dBm 0 dBm and recommended range is 15 dBm to 5 dBm 1 If the signal level is out of range use extra devices e g attenuator to make adjustments 2 If the signal le...

Страница 22: ...e pre correction data immediately and leave the corresponding status on the front panel LCD Press any key to cancel the ADPC function manually and restart the ADPC function again after the problems ar...

Страница 23: ...the bit rate required Solution Adjust the TS input bit rate Or connect all devices with the same reference clock GPS Note When in Exciter Mode it has bit rate auto adaptation function to deal with the...

Страница 24: ...translator 5 3 GPS No GPS Alarm message LCD GPS NoGPS LED_ GPS Off Cause This warning displays when no external GPS is connected Solution Check the connection with external GPS device GPS Unlocked Ala...

Страница 25: ...IMD or SNR during ADPC process does not pass the pre set threshold Solution Cancel the ADPC function manually and then check the status of connection and entire transmitting system Start the ADPC fun...

Страница 26: ...d reception The LED lights on the front panel could provide some indications in these situations Or check the setting of RF via front panel serial port or WEB interface and ensure it s turned ON Resta...

Отзывы: