Anyscene 512 Operating 

Instructions 

 

1.  Overview and Operation 
 

The front panel has ten buttons and ten LED indicators.  Switches labelled 1-7 have their 
own  blue  mimic  LEDs  and  are  used  for  storing  and  recalling  the  contents  of  the  23 
programmable memories.   

 

The Up and Down buttons are normally used to control the Master level, allowing control 
of  the  overall  lighting  level.    They  also  provide  access  to  the  upper  and  lower  memory 
banks, each of eight scenes.   

 

The  green  power  LED  shows  when  the  unit  is  powered  up,  and  the  yellow  data  LED 
indicates that the unit is receiving suitable programming data from a DMX source. Switch 
0 is the blackout switch and when enabled the corresponding red LED will flash to indicate 
the unit is in this mode. 

 

The RJ45 sockets are on the back of the PCB along various option DIL switches and the 
connectors for the external scene recall control. 
 
The Anyscene 512 is also available with a reduced number of buttons for applications that 
require  less  than  the  standard  number  of  scenes.  These  include  a  4-button  version 
allowing four user defined scenes to be programmed / recalled and a 5-button version that 
also has the four user defined scenes, plus the blackout function / button of the standard 
unit. 

 
 
2.  Mounting 

 
The Anyscene 512 should be mounted using UK double pattresses with an approximate 
depth of 32 mm. 
 

 

 

Содержание Anyscene 512

Страница 1: ...he system rests with the installer and these notes are intended only for guidance Contents 1 Overview and Operation 2 2 Mounting 2 3 Power Supply Connection 3 4 DMX Requirements 4 4 1 DMX Loading 4 4...

Страница 2: ...t is powered up and the yellow data LED indicates that the unit is receiving suitable programming data from a DMX source Switch 0 is the blackout switch and when enabled the corresponding red LED will...

Страница 3: ...o 50 mA When using multiple Anyscene 512 they should be linked together in series with each other and then linked to the receiving equipment Anytronics dimmers or the AS180 If used with other Anytroni...

Страница 4: ...ced in any order along the DMX line but the equipment at either end of this DMX line whether receiving equipment or an Anyscene 512 should have a termination resistor fitted for best results 4 3 Line...

Страница 5: ...512 units into a standby receive state To ensure that the scene memory contents remain intact in such multiple unit installations it is vital that once scene programming has been completed the MWP swi...

Страница 6: ...on 1 RFP No Function 2 MWP ON Internal memory protected Normal Operation OFF Internal memory not protected Programming Mode 3 256 No Function 4 Master Speed See Section 6 2 5 Fade x2 See Section 6 3 6...

Страница 7: ...DIL No Name Function 1 MEM ON Internal memory protected Normal Operation OFF Internal memory not protected Programming Mode 2 Master Speed See Section 6 2 3 Fade x2 See Section 6 3 4 Fade x4 See Sect...

Страница 8: ...alter the duration and speed of the cycling As supplied with DIL switch 4 set to OFF the default time spent in each scene is approximately 10 seconds Master Speed DIL OFF The Up and Down buttons can b...

Страница 9: ...as follows Fade x 2 Fade x 4 Fade Time Seconds OFF OFF 2 5 OFF ON 5 ON OFF 10 ON ON 20 6 4 Clearing All Memories To clear all saved scenes within the Anylight 512 the following procedure should be fo...

Страница 10: ...flash twice to show the data has been saved h Repeat e to g for all required scenes i Once all scenes have bee saved turn the MWP DILL ON to protect the recently programmed scenes Note To access scene...

Страница 11: ...cene from the 1 7 scene cycle will be selected on each contact closure To facilitate debouncing of contact closure contact closing inputs which occur less than two seconds after the previous contact c...

Страница 12: ...rating Instructions 8 2 Post July 2018 Models The post 2018 models have the ability to recall individual scenes using external zero voltage contacts and the bank of screw terminals provided on the rea...

Страница 13: ...put to DMX addresses 1 512 o Low voltage closing contact input for external scene recall Controls o 8 scene selection buttons o Master level up and down buttons o External scene recall via low voltage...

Отзывы: