anytronics Anyscene 512 Скачать руководство пользователя страница 1

 

Units 5 & 6 Hillside Industrial Estate 
London Road, Horndean,  
Hampshire, PO8 0BL 
Tel +44 (0)23 9259 9410    
Fax +44(0)23 9259 8723

   

 

Page 1 of 13 

AT1039 Issue 1 

Anyscene 512 Operating 

Instructions 

 

 
 
 

Installation and Operation Guide for the Anytronics Anyscene 512 Scene Recall Unit 

 
This equipment should only be installed by competent electricians, the responsibility for safe 
and correct installation of the system rests with the installer and these notes are intended only 
for guidance. 
 
 
 

Contents 

 
1.

 

Overview and Operation .............................................................................................. 2

 

2.

 

Mounting ...................................................................................................................... 2

 

3.

 

Power Supply & Connection ........................................................................................ 3

 

4.

 

DMX Requirements ..................................................................................................... 4

 

4.1.  DMX Loading ........................................................................................................................ 4 

4.2.  DMX Wiring .......................................................................................................................... 4 

4.3.  Line Bias Network ................................................................................................................ 4 

4.4.  DMX Backup ......................................................................................................................... 4 

5.

 

Multiple Anyscene 512 ................................................................................................ 5

 

5.1.  Commissioning ..................................................................................................................... 5 

6.

 

Configuration ............................................................................................................... 6

 

6.1.  Auto Cycle Mode ................................................................................................................. 8 

6.2.  Master / Speed Settings ....................................................................................................... 8 

6.3.  Fade Rate ............................................................................................................................. 9 

6.4.  Clearing All Memories .......................................................................................................... 9 

7.

 

Programming ............................................................................................................. 10

 

7.1.  Single Anyscene 512 .......................................................................................................... 10 

7.2.  Multiple Anyscene 512 ...................................................................................................... 10 

8.

 

External Scene Control ............................................................................................. 11

 

8.1.  Pre-July 2018 Models ......................................................................................................... 11 

8.2.  Post-July 2018 Models ....................................................................................................... 12 

9.

 

Specification .............................................................................................................. 13

 

 

 

 

Содержание Anyscene 512

Страница 1: ...he system rests with the installer and these notes are intended only for guidance Contents 1 Overview and Operation 2 2 Mounting 2 3 Power Supply Connection 3 4 DMX Requirements 4 4 1 DMX Loading 4 4...

Страница 2: ...t is powered up and the yellow data LED indicates that the unit is receiving suitable programming data from a DMX source Switch 0 is the blackout switch and when enabled the corresponding red LED will...

Страница 3: ...o 50 mA When using multiple Anyscene 512 they should be linked together in series with each other and then linked to the receiving equipment Anytronics dimmers or the AS180 If used with other Anytroni...

Страница 4: ...ced in any order along the DMX line but the equipment at either end of this DMX line whether receiving equipment or an Anyscene 512 should have a termination resistor fitted for best results 4 3 Line...

Страница 5: ...512 units into a standby receive state To ensure that the scene memory contents remain intact in such multiple unit installations it is vital that once scene programming has been completed the MWP swi...

Страница 6: ...on 1 RFP No Function 2 MWP ON Internal memory protected Normal Operation OFF Internal memory not protected Programming Mode 3 256 No Function 4 Master Speed See Section 6 2 5 Fade x2 See Section 6 3 6...

Страница 7: ...DIL No Name Function 1 MEM ON Internal memory protected Normal Operation OFF Internal memory not protected Programming Mode 2 Master Speed See Section 6 2 3 Fade x2 See Section 6 3 4 Fade x4 See Sect...

Страница 8: ...alter the duration and speed of the cycling As supplied with DIL switch 4 set to OFF the default time spent in each scene is approximately 10 seconds Master Speed DIL OFF The Up and Down buttons can b...

Страница 9: ...as follows Fade x 2 Fade x 4 Fade Time Seconds OFF OFF 2 5 OFF ON 5 ON OFF 10 ON ON 20 6 4 Clearing All Memories To clear all saved scenes within the Anylight 512 the following procedure should be fo...

Страница 10: ...flash twice to show the data has been saved h Repeat e to g for all required scenes i Once all scenes have bee saved turn the MWP DILL ON to protect the recently programmed scenes Note To access scene...

Страница 11: ...cene from the 1 7 scene cycle will be selected on each contact closure To facilitate debouncing of contact closure contact closing inputs which occur less than two seconds after the previous contact c...

Страница 12: ...rating Instructions 8 2 Post July 2018 Models The post 2018 models have the ability to recall individual scenes using external zero voltage contacts and the bank of screw terminals provided on the rea...

Страница 13: ...put to DMX addresses 1 512 o Low voltage closing contact input for external scene recall Controls o 8 scene selection buttons o Master level up and down buttons o External scene recall via low voltage...

Отзывы: