5
AT-D878U Digital DMR and Analog UHF Two Way Radio
STATUS
LED
Self-Test When Power on
Red (for 1 second)
No Battery
Green
Charge Normally
Red
Fully Charged
Green
Trouble
Red blinks fast for a long time
f
. LED Indicator:
Charging Status
Indicator Status
Standby (Self-examine lights red
1second when power on)
None
Charging
(Charge in a constant current)
Lights red for about 3 hours
Fully charged
(Charge in a constant voltage)
Lights green
»
Trouble means battery too warm, battery short-circuited or
charger short-circuited.
2.5
Normal Charging Tips
a.
Self-Test:
When powering on the charger, the red light turns on and then
turns off and stays off, which means the charger has passed it self- test
and it is ready to charge the battery. If the light remains orange or the
red light blinks, it means the charger cannot pass it self-test and cannot
charge the battery.
b.
Trickle Pre-Charging:
If red light blinks when the battery is inserted
into the charger, it means that the battery voltage is low and the charger
is trickle-charging the battery (Pre-Charging Mode). The charger will
automatically turn into normal charging when the battery reaches a
certain electric charge, and if the red light stops blinking, it means the
battery voltage has reached a certain level, and the charger will charge
the battery in normal mode.
e
. Charging Process
2. BATTERY INFORMATION
-