Anyload A1A Скачать руководство пользователя страница 4

 
 

ANYLOAD A1A Amplifier Product Manual (V1611)

 

 
 

 

From Load Cell to Amplifier: 

+S:+Output mV Signal 
-S:-Output mV Signal 
+E:+Excitation 
-E: -Excitation 
 

4.

 

Specifications 

 
Power Supply: 24V DC 

 

}10%,<3W  Maximum Input Voltage:30V DC 

Input Signal: 0~30mV  

 

 

Maximum Output Current: 40mA 

Output Signal: 0~10V/4~20mA  

 

Maximum Output Voltage: 15V 

Operating Temperature: -10°C~40°C 
Operating Humidity :  ≤90%R.H. 
 

5.

 

Calibration 

 

The calibration of A1A consists of Zero Calibration and Span Calibration: 

 
5.1 Zero Calibration 
Step1.Remove all load from the scale platform. If the scale require hooks or 
chains (tare weight), place the hooks or chains into the scale for zero 
calibration. 
 
Step2.Adjust ZERO variable resistor to an output of 0V or 4mA. 

(Note: Tare weight shall not exceed 30% of full load) 
 

5.2

 

Span Calibration 

Step1.Place full load into the scale. 
 
Step2. Adjust SPAN variable resistor to an output of 10V or 20mA. 
 
(

Note: 

It’s recommended to repeat adjustment in Step 2 of Section 5.2 above 

three times.) 

 

6.

 

Operation 

 

6.1 Except during calibration, always keep the enclosure cover on and ensure 
the seal is properly fitted when installing the cover. 
 
6.2 Always keep the amplifier clean from dirt to avoid affecting the values of 
the ZERO and SPAN variable resistors. 
 

Отзывы: