5. Electrical Specifications
5.1 DC Electrical Specifications
5.1.1 Absolute Maximum Ratings
Operating the module under conditions that exceed those listed in the Absolute Maximum Ratings
table may result in damage to the module.
Absolute Maximum Ratings should be considered as limiting values. The module may not function
properly and should not be operated if any one of the parameters is not within its specified operating
range.
Table 5-1 Absolute Maximum Ratings
PARAMETER
MIN
MAX
UNITS
Storage Temperature
-50
+85
”
C
Voltage On Any Input or Output Pin
-0.8
+4.8
V
Supply Voltage
-1.0
+5.0
V
Initializing Current
250
mA
Drop
No damages after 60-Inch drop over concrete floor
5.1.2 Recommended Operating Conditions
PARAMETER
MIN
TYP
MAX
UNITS
Supply Voltage
+3.4
+3.8
+4.2
V
Operating Temperature
-30
+60
”
C
Operating Humidity
95% (50
°
C) Relative Humidity
5.1.3 Power Consumption
STANDBY
CONVERSATION
(Busy)
Idle
Sleep
900mA (MAX)
110mA
2mA