Configuration
12 (30)
4.3
Anybus Configuration Manager - IIoT
The IIoT interface is configured using
Anybus Configuration Manager - IIoT
, which can be
downloaded from
www.anybus.com/support
.
Fig. 8
Anybus Configuration Manager - IIoT
Setting up the IIoT tags
1.
Select either OPC UA or MQTT as communication protocol.
For OPC UA you must also specify a
Namespace URI
. If this field is left empty a default
value will be used.
2.
Click on
Add
to add IIoT tags as required. The data types and addresses of the tags must
match the IO data mapping set up with Anybus Configuration Manager - X-gateway.
Fig. 9
Adding tags
3.
Optionally, select
File ► Save
to save the current configuration project.
Note:
The project file saves the current settings in Anybus Configuration Manager - IIoT and
can be used as a starting point when creating configurations. It cannot be used as a
configuration file by the Anybus X-gateway IIoT Interface.
When you have finished setting up the IIoT tags you must generate a configuration and apply it
to the Anybus X-gateway IIoT Interface. This can be done directly from Anybus Configuration
Manager - IIoT or by saving a configuration file and using an external FTP client.