![Anybus Wireless Bolt Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/anybus/wireless-bolt/wireless-bolt_reference-manual_2948747082.webp)
S Registers
80 (88)
4
S Registers
4.1
ATS S Registers
Changes made to S registers requires reboot
Standard Registers
Register
Name
Value Range
Default Value
Description
3
Command
Line
Termination
Character
1..127
13
This setting changes the decimal value of the
character recognized by the DCE from the DTE to
terminate an incoming command line. It is also
generated by the DCE as part of the header, trailer,
and terminator for result codes and information text
along with the S4 parameter. The previous value of
S3 is used to determine the command line
termination character for entry of the command line
containing the S3 setting command. However, the
result code issued shall use the value of S3 as set
during the processing of the command line. For
example, if S3 was previously set to 13 and the
command line "ATS3=30" is issued, the command
line shall be terminated with a CR, character (13),
but the result code issued will use the character with
the ordinal value 30 in place of the CR.
4
Response
Formatting
Character
1..127
10
This setting changes the decimal value of the
character generated by the DCE as part of the
header, trailer, and terminator for result codes and
information text, along with the S3 parameter. If the
value of S4 is changed in a command line, the result
code issued in response to that command line will
use the new value of S4.
5
Backspace
Character
0..255
8
This setting changes the decimal value of the
character recognized by the DCE as a request to
delete from the command line the immediately
preceding character.
Miscellaneous Registers
Register
Name
Value Range
Default Value
Description
1000
Reserved
1001
Reserved
1002
Ignore
Broadcast
Layer 2 AT
0..1
0
Setting this register to 1 will ignore Layer2 AT
broadcast packets
1003
Event
Subscriber
Protocol
0..255
0
Bit mask deciding how events should be sent.
Bit 0: Send events over TCP AT connections
Bit 1: Send events over Layer-2 (mac_address must
be specified, using AT*AMESS)
Bit 2: Send events over Syslog
1004
Event
Subscriber
Ethernet Type
0..65535
0
The 16 bit Ethernet type to use when sending
events over layer 2
1005
Event
Subscriber
Syslog Port
0..65535
0
The 16 bit UDP port to use when sending events
using Syslog
1006
Bridge Cache
Timeout
0..255
2
Time in seconds before mac address cache table in
the bridge throws away an entry.
1007
Easy Config
LED Mode
0..3
3
Bit mask representing Easy Config LED Mode when
smart mode is finished
Value 0: Link quality LEDs are off
Value 1: WLAN RSSI
Value 2: BT Link Quality
Wireless Bolt
™
/ Wireless Bridge II
™
Reference Guide
SCM-1202-004 EN 1.7