9.3 Diagnostic Object (02h)
General Information
Basic
Object Description
This object provides a standardised way of handling host application events & diagnostics, and is thor-
oughly described in the general Anybus CompactCom 40 Software Design Guide.
Supported Commands
Object:
Get_Attribute
Create
Delete
Instance:
Get_Attribute
Object Attributes (Instance #0)
Instance Attributes
Basic
In this implementation, the severity level of all instances are combined (using logical ‘OR’) and repre-
sented on the network through the CIP Identity Object.
See also...
• “Diagnostics” on page 18
• “Identity Object (01h)” on page 63 (CIP-object)
#
Name
Access Data Type
Value
1... 4
-
-
-
Consult the general Anybus CompactCom 40 Software
Design Guide for further information.
11
Max no. of instances
Get
UINT16
5+1 (One instance is reserved for major diagnostic
events.)
12
Supported functionality Get
BITS32
00 00 00 00h (Latching events are not supported.)
#
Name
Access Type
Value
1
Severity
Get
UINT8
Consult the general Anybus CompactCom 40 Software
Design Guide for further information.
2
Event Code
a
a. This attribute can not be represented on the network and is thus ignored by the module.
Get
UINT8
3
-
-
-
Not implemented in product.
4
Slot
Get
UINT16
Consult the general Anybus CompactCom 40 Software
Design Guide for further information.
5
Get
UINT16
6
Get UINT8
7
Bit
Get
UINT8