background image

Preparation

7 (124)

3

Preparation

3.1

Support and Resources

For additional documentation and software downloads, FAQs, troubleshooting guides and
technical support, please visit

www.anybus.com/support

.

Have the product article number available, to search for the specific product page. You find the product
article number on the product cover.

Anybus

®

Managed Industrial L3 Switch User Manual

SCM-1202-151 1.1 en-US

Содержание AWB5011

Страница 1: ...Anybus Managed Industrial L3 Switch USER MANUAL SCM 1202 151 1 1 en US ENGLISH ...

Страница 2: ...of possible applications of the product and because of the many variables and requirements associated with any particular implementation HMS Industrial Networks cannot assume responsibility or liability for actual use based on the data examples or illustrations included in this document nor for any damages incurred during installation of the product Those responsible for the use of the product mus...

Страница 3: ...ntended Use 6 2 2 General Safety 6 3 Preparation 7 3 1 Support and Resources 7 4 Installation 8 4 1 DIN Rail Mounting 8 4 2 Connecting Ground Screw 9 4 3 Terminal Block Connector 10 4 4 Installing Terminal Block 10 4 5 Connecting Digital Output Wires 11 4 6 Connecting Digital Input Wires 12 4 7 Connecting Power Wires 13 4 8 Connecting to Ethernet Network 14 4 9 Connecting to Fiber Network 14 ...

Страница 4: ... 11 VLAN 58 5 12 Quality of Service QoS 65 5 13 Multicast 69 5 14 Routing 72 5 15 SNMP 84 5 16 Security 87 5 17 Warning 96 5 18 Diagnostics 101 6 Verify Operation 106 6 1 System LED Indicators 106 6 2 Ethernet LED Indicators 106 6 3 SFP Port LED Indicators 107 7 Maintenance and Troubleshooting 108 7 1 USB Port 108 7 2 Backup and Restore 108 7 3 Firmware Upgrade 110 7 4 Reset To Default 111 7 5 Fac...

Страница 5: ...Redundancy 118 D 1 Spanning Tree Protocol STP 118 D 2 Rapid Spanning Tree Protocol RSTP 118 D 3 Multiple Spanning Tree Protocol MSTP 118 E About Ethernet Ring Protection Switching ERPS 120 F About Virtual Local Area Network VLAN 121 G About Open Shortest Path First OSPF 122 H About Simple Network Management Protocol SNMP 123 ...

Страница 6: ...This page intentionally left blank ...

Страница 7: ...ated with bold text Program code and script examples Cross reference within this document Document Conventions p 5 External link URL www hms networks com WARNING Instruction that must be followed to avoid a risk of death or serious injury Caution Instruction that must be followed to avoid a risk of personal injury Instruction that must be followed to avoid a risk of reduced functionality and or da...

Страница 8: ...specified by the manufacturer the protection provided by the equipment may be impaired 2 2 General Safety Caution Ensure that the power supply is turned off before connecting it to the equipment Connecting power with reverse polarity or using the wrong type of power supply may damage the equipment Make sure that the power supply is connected correctly and of the recommended type Anybus Managed Ind...

Страница 9: ...wnloads FAQs troubleshooting guides and technical support please visit www anybus com support Have the product article number available to search for the specific product page You find the product article number on the product cover Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 10: ...DIN rail in accordance with the EN 50022 standard Procedure Mount the switch on a DIN rail 1 Insert the upper end of the DIN rail clip into the DIN rail 2 Push the bottom of the DIN rail clip into the DIN rail Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 11: ...oid system damage the equipment should be connected to ground Procedure 1 Establish a direct connection between the ground screw and the grounding surface prior to connecting devices Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 12: ... 4 DI Digital Input 5 P2 Power Input 2 6 P2 Power Input 2 7 P1 Power Input 1 8 P1 Power Input 1 4 4 Installing Terminal Block Procedure 1 Attach the terminal block to the contact on the switch 2 Fasten the terminal block with the 2 screws included Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 13: ... triggered the two wires attached to the DO fault contacts form a close circuit The fault circuit remains opened until a user configured event occur Procedure Connect the Digital Output DO 1 Insert the wires into the 2 pin DO contact on the 8 pin terminal block 2 Tighten the wire clamp screws Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 14: ...gital Input Wires Procedure Connect the Digital Input DI 1 Insert the wires into the 2 pin DI and DI contact on the 8 pin terminal block 2 Tighten the wire clamp screws Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 15: ...A current 24 VDC Procedure 1 Connecting to main power supply P1 Insert the positive and negative wires into the P1 and P1 contact on the 8 pin terminal block 2 Connecting to redundant power supply P2 Insert the positive and negative wires into the P2 and P2 contact on the 8 pin terminal block 3 Tighten the wire clamp screws 4 Connect the power wires to a DC switching type power supply Anybus Manag...

Страница 16: ...ng to Ethernet Network Optional Connect the switch to an Ethernet network 4 9 Connecting to Fiber Network Optional Connect the switch to a network via the SFP port Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 17: ...the web management interface Before You Begin Connect the switch to your computer Connect the switch to power To link your computer with the switch make sure that the IP address of the computer is located in the same subnet as the switch default IP address Procedure Access the web management interface 1 In your browser type http IP address and press Enter The web based management interface login s...

Страница 18: ...nges click Cancel Some pages have additional buttons that are described in the respective sections in this manual To save changed settings permanently click Save in the configuration page top menu The recent changes will otherwise be discarded if the switch is rebooted 5 3 2 To Logout From the Web Interface To manually logout from the system 1 In the web interface top menu click Logout 2 To confir...

Страница 19: ...n Fig 2 Switch information Configure the switch information System Name Name of the unit that will be shown on the network Default switch System Location Specify the physical location of the switch Default blank Software Contact Specify a contact person Enter name mail address or other information Default blank OID Switch Object ID System Description Product name Software Version Latest installed ...

Страница 20: ...ace The default authority allows the user to configure all configuration parameters For security consideration please change the password after first login to the web interface The default switch login user name is admin and the password is admin Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 21: ...new user name here Privilege Select the local user privilege level New Password Default admin Enter a new password here Confirm Password Re enter the new password to confirm it To apply the settings click Submit To cancel the changes click Cancel Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 22: ...r IP Enter the IP address of the RADIUS server in Server IP Address Shared Key Enter the Shared Secret of the RADIUS server Shared key is used to verify that RADIUS messages with the exception of the Access Request message are sent by a RADIUS enabled device that is configured with the same shared key Shared key also verify that the RADIUS message has not been modified in transit message integrity...

Страница 23: ...tings click Submit IPv4 Configuration Configure the IPv4 settings IP Address Default 192 168 10 1 Set up the IP address reserved by User network for User switch If the DHCP Client function is enabled do not assign an IP address to the switch as it will be overwritten by the DHCP server Subnet Mask Default 255 255 255 0 Assign the subnet mask for the IP address If the DHCP Client function is enable...

Страница 24: ... four hexadecimal digits each group representing 16 bits two octets The groups are separated by colons The length of an IPv6 address is 128 bits IPv6 address example fe80 212 77ff feff 1acb 64 IPv6 Setting Fig 6 IPv6 Setting Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 25: ... must be formatted according to the RFC 2373 IPv6 Addressing Architecture using 8 colon separated 16 bit hexadecimal values One double colon may be used in the address to indicate the appropriate number of zeros required to fill the undefined fields To apply the settings click Submit IPv6 Address To delete an address select the address and click Remove To reload the information click Reload Neighb...

Страница 26: ...rom PC to get the PC time setting Time Zone To adjust the time zone based on the user area select a Time Zone NTP To Enable NTP Client update select the checkbox Make sure that the switch is connected to the internet The system will send request packet to acquire current time from the NTP server that assigned 1st Time Server 2nd Time Server Select the NTP Server from the list which should adjust t...

Страница 27: ...ult 0 1s Announce Interval Set the announce message interval Default 1 2s Announce Receipt Timeout The multiple of announce message receipt timeout by the announce message interval Default 6 Minimum Path Delay Request Message Interval Minimal delay request message interval Default 1 2s Domain Number Subdomain name IEEE 1588 2002 or the domain Number IEEE 1588 2008 fields in PTP messages First Prio...

Страница 28: ...priority Default 128 Delay Mechanism Configures the delay mechanism in boundary clock mode E2E The delay request or response mechanism used in the boundary clock mode P2P The peer to peer mechanism used in the boundary clock mode Default E2E To apply the settings click Submit 5 8 DHCP Server 5 8 1 DHCP Server Setting Fig 9 DHCP Server Setting Anybus Managed Industrial L3 Switch User Manual SCM 120...

Страница 29: ...ers as DHCP Clients When DHCP Server is enabled it will automatically assign IP addresses to the computers connected to the LAN private network Set the computers to be DHCP clients by setting their TCP IP settings to Obtain an IP Address Automatically When the user turn on the computer device the TCP IP settings provided by the switch are automatically loaded If the users manually assigns IP addre...

Страница 30: ...inding rule from the list click Remove To reload the information click Reload 5 8 4 Static MAC IP Binding List Fig 12 Static MAC IP Binding List Configure the MAC IP Binding settings MAC Address Enter the MAC address IP Address The IP address that will assign to the device with the Binding MAC address Enter the IP address and click Add To remove a binding rule from the list click Remove To reload ...

Страница 31: ...Enter the Circuit ID of the device that wishes binding Remote ID Enter the Remote ID of the device that wishes binding IP Address Enter the IP address that will assign to the device with the Binding MAC address Click Add To remove a binding rule from the list click Remove Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 32: ...on 82 is enabled a subscriber device is identified by the switch port through which it connects to the network in addition to its MAC address The DHCP packets from client will be modified by the policy and forwarded to DHCP server through the gateway port Helper Address Enter a DHCP Server IP address and click Add To remove a binding rule from the list select the checkbox and click Remove Anybus M...

Страница 33: ...fault setting Replaces the existing option 82 field and adds new option 82 field Keep Keeps the original option 82 field and forwards to server Drop Drops the option 82 field and do not add any option 82 field To apply the settings click Submit Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 34: ...ote ID Setting Circuit ID The Circuit ID is a 4 byte number generated by the Ethernet switch Before you begin ensure that the DHCP Relay Agent function is enabled refer to DHCP Option 82 p 30 The format of the Circuit ID is 00 01 00 01 The first byte is 00 the second and the third byte 01 00 is formed by the port VLAN ID and the last byte 01 is formed by the port number Anybus Managed Industrial L...

Страница 35: ...D The Remote ID identifies the relay agent itself and can be one of the following The IP address of the relay agent The MAC address of the relay agent A combination of IP address and MAC address of the relay agent A user defined string To apply the settings click Submit Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 36: ...7 DHCP Leased Entries Settings Configure the DHCP Leased Entries settings IP Address IP address that was assigned by switch MAC Address MAC address that was assigned by switch Leased Time Remains Remains time for the IP address leased To reload the information click Reload Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 37: ...00 half 10 full 10 half mode for Giga Ethernet Port 1 8 ge1 ge8 For Gigabit Ethernet Port 9 12 ge9 ge12 it can be set up to 100M Full Duplex 100 Full only Default AutoNegotiation Flow Control Enable Activate the flow control function to let the flow control of that corresponding port on the switch to work Disable The flow control of the corresponding port on the switch will work automatically Defa...

Страница 38: ...s monitoring the real time parameters of the fiber optic transceivers like optical input output power temperature and transceiver supply voltage of an SFP module via SFP DDM section The real time diagnostic parameters can be monitored to alert the system when the transceiver specified operating limits are exceeded and compliance cannot be ensured Anybus Managed Industrial L3 Switch User Manual SCM...

Страница 39: ... scan the SFP transceiver module and show the statistics click Scan All To eject selected SFP transceivers or plug SFP transceivers click Eject All 5 9 3 Port Trunk Port Trunk Setting Fig 20 Port Trunk Setting Configure the Port settings The switch can support up to 8 trunk groups with 2 trunk members Since the member ports should use the same speed duplex max trunk members would be 8 for 100Mbps ...

Страница 40: ...ion MAC address src dst mac Load distribution is based on the source and destination MAC address src ip Load distribution is based on the source IP address dst ip Load distribution is based on the destination IP address src dst ip Load distribution is based on the source and destination IP address To apply the settings click Submit To reload the information click Reload Anybus Managed Industrial L...

Страница 41: ...g Aggregated Ports When LACP link is well the member ports are shown in the aggregated column Individual Ports When LACP is enabled member ports of LACP group which are not connected to correct LACP member ports are shown in the Individual column Link Down Ports When LACP is enabled member ports of LACP group which are not linked up are shown in the Link Down column To reload the information click...

Страница 42: ...s at each port can be programmed Fig 23 Rate Control Configure the Rate Control settings Rate Ingress Egress Default value Ingress rule 0 kbps Default value Egress rule 0 kbps 0 stands for disabling the rate control for the port Valid values are increments of 64 kbps from 64 1 000 000 kbps To apply the settings click Submit Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 43: ...LAN from being disrupted by a broadcast DLF or multicast storm on a port Fig 24 Storm Control Setting Configure the Storm Control for each port Broadcast Set enable to control Broadcast Packets Default Disable DLF Set enable to control Destination Lookup Failure packets Default Disable Multicast Set enable to control Multicast Packets Default Disable Rate Packet Sec Rate limit value 0 262142 packe...

Страница 44: ...Frame settings Enter the size of the Maximum Transmission Unit MTU The default value is 1 518 bytes The maximum Jumbo Frame size is 9 216 bytes To apply the settings click Submit To reload the information click Reload Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 45: ...onship exists between domains based on levels The larger the domain the higher the level value Recommended values of levels Customer Domain Largest Provider Domain In between e g 3 Operator Domain Smallest Domain Name Enter a Domain Name Maximum 43 characters To add the settings click Add Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 46: ...l CFM frames of its level or lower that come from the wire side Domain Association Name Choose the Domain Association Name that has been added Endpoint Type Choose between Local Endpoint and Remote Endpoint Local Endpoint Set the port as the Continuity Check Message CCM sender Remote Endpoint Set the port as the Continuity Check Message CCM receiver Default Local Endpoint Port Choose port that nee...

Страница 47: ...ettings click Submit To cancel settings click Cancel To remove the list select the list and click Remove Selected Endpoint Table Fig 29 Endpoint Table View the endpoint entry To remove the list select the list and click Remove Selected To cancel settings click Cancel Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 48: ...AC address Bridge Priority Enter a value from 0 to 61440 RSTP uses bridge ID to determine the root bridge the bridge with the highest bridge ID becomes the root bridge The bridge ID is composed of bridge priority and bridge MAC address The bridge with the highest priority becomes the highest bridge ID If all the bridge ID has the same priority the bridge with the lowest MAC address will become the...

Страница 49: ... to check current STP status The root bridge of the spanning tree topology periodically sends out a hello message to other devices on the network to check if the topology is normal The hello time is the amount of time the root has waited during sending hello messages Forward Delay Time Enter a value between 4 and 30 seconds This value is the time that a port waits before changing from Spanning Tre...

Страница 50: ...This function allows link status of the link to be manipulated administratively Auto means to auto select P2P or Share mode P2P means P2P is enabled the 2 ends work in full duplex mode Share means P2P is disabled the 2 ends may connect through a share media and work in half duplex mode Edge Port A port directly connected to the end stations cannot create a bridging loop in the network To configure...

Страница 51: ... Root Path Cost and the Max Age Hello Time and Forward Delay of BPDU sent from the root switch Port Status View the port Role Port State Path Cost Port Priority Link Type Edge Port and Aggregated ID Type To reload the information click Reload Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 52: ...on The network can be divided virtually to different Regions The switches within the Region should have the same Region and Revision level Region Name The name for the Region Maximum length 32 characters Revision The revision for the Region Range 0 65535 Default 0 To apply the settings click Submit To cancel settings click Cancel Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en ...

Страница 53: ... to the instance 0 61440 To add the settings click Add MST Instance Configuration The table shows the current MST Instance Configuration added To apply the settings click Submit To delete an instance select the instance and click Remove Selected To cancel settings click Cancel MSTP Port Setting Fig 34 MSTP Port Setting Enabled MSTP and linked up ports within the instance are listed in the Instance...

Страница 54: ... the rapid state transitions that are possible within RSTP depend upon whether the port of concern can only be connected to another bridge i e it is served by a point to point LAN segment or if it can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows link status of the link to be manipulated administratively Auto means to auto select P2P or Sh...

Страница 55: ...tus View Root Address Root Priority Root Port Root Path Cost and the Max Age Hello Time and Forward Delay of BPDU sent from the root switch based on the Instance ID Port Status View Port Role Port State Path Cost Port Priority Link Type and the Edge Port within the instance To reload the information click Reload Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 56: ...g 36 ERPS Setting Before mapping VLAN to Instance create VLAN and assign the member ports refer to VLAN Setting p 58 Add ERPS Instance Map the VLAN to Instance Instance ID Select the Instance ID and click Add The available number is 1 15 VLAN Group Type the VLAN ID that user wants mapping to the instance Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 57: ... the Ring Select the port number that belongs to Ring port 0 Ring Port 1 This will create Port 1 of the switch in the Ring As interconnected sub ring will have only one ring port Port 1 is configured as 0 for interconnected sub ring 0 in this field indicates that no Port 1 is associated with this instance Select the port number that belongs to Ring port 1 RPL Port This allows you to select the Rin...

Страница 58: ...0 ms steps between 10 ms and 2000 ms with a default value of 100 ms WTR Timer m The Wait To Restore timing value to be used in revertive switching The period of the WTR time can be configured by the operator in 1 minute steps between 1 and 12 minutes with a default value of 5 minutes To apply the settings click Submit To cancel settings click Cancel 5 10 4 ERPS Status Fig 38 ERPS Status Anybus Man...

Страница 59: ... as the RPL block Revertive Mode Revertive mode after the conditions causing a protection switch has cleared the traffic channel is restored to the working transport entity that is blocked on the RPL In Non Revertive mode the traffic channel continues to use the RPL if it is not failed after a protection switch condition has cleared Default Revertive Manual Switch Status from the Ring Port 0 and 1...

Страница 60: ...PL Blocked NR RB being sent R APS NR RB Rx The number of R APS messages with a No Request RPL Blocked NR RB being received R APS NR Tx The number of R APS messages with a No Request NR being sent R APS NR Rx The number of R APS messages with a No Request NR being received Node State Transition Count The number of state transition that detected in the Ring To reload the information click Reload 5 1...

Страница 61: ...tting table The VLAN remain in status Unused until ports are added to the VLAN Static VLAN Setting Configure the Static VLAN settings Not available U Untag Indicates that egress outgoing frames are not VLAN tagged T Tag Indicates that egress outgoing frames are to be VLAN tagged To configure Egress rules 1 Select the VLAN ID The entry of the selected VLAN turns to light blue 2 Assign the Egress ru...

Страница 62: ... valid and available in this column Tunnel Mode Default None None Not used 802 1Q Tunnel As the Ingress port is connected to the client port Configures Q in Q tunneling for a client access port to segregate and preserve customer VLAN IDs for traffic crossing the service provider network 802 1Q Tunnel Uplink As the egress port that is the middle switch port Configures Q in Q tunneling for an uplink...

Страница 63: ...not Example If a tagged frame from Management VLAN is received and Ingress Filtering is enabled the switch will determine if the port is on the Management VLAN s Egress list If it is the frame can be processed If it s not the frame would be dropped To apply the settings click Submit 5 11 3 VLAN Status Fig 41 VLAN Status View the current status of the VLAN including VLAN ID Name Status and Egress r...

Страница 64: ...ing Enter the VLAN ID and the Private VLAN Type for each VLAN you want to configure To apply the settings click Submit 5 11 5 PVLAN Port Setting Port Configuration Fig 43 PVLAN Port Setting Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 65: ... port type the web UI display the available VLAN ID the port can associate to Private VLAN Association Secondary VLAN Secondary VLAN is included Isolated and Community VLAN Type is assigned in the Private VLAN Configuration section Primary VLAN Primary VLAN is included the Primary VLAN Type is assigned in the Private VLAN Configuration section To apply the settings click Submit 5 11 6 PVLAN Status...

Страница 66: ...tocol settings GVRP Protocol Default Disable Enable or Disable the GVRP function globally State Default Disable After enable GVRP globally you still can enable disable GVRP by port Join Timer Default 20 Controls the interval of sending the GVRP Join BPDU An instance of this timer is required on a per Port per GARP Participant basis Leave Timer Default 60 Control the time to release the GVRP reserv...

Страница 67: ...f 802 1P is selected the switch relies on a packet s CoS information to determine priority This is related to the settings in the CoS Queue Mapping page DSCP TOS Code Point If DSCP TOS is selected the switch relies on a packets differentiated services code point information to determine the priority This is related to the settings in the DSCP Priority Mapping page Select Queue Scheduling rule Roun...

Страница 68: ...he Queue 7 is the highest port based queue 0 is the lowest queue The traffic injected to the port follows the queue level to be forwarded but the outgoing traffic does not bring the queue level to next switch To apply the settings click Submit To cancel settings click Cancel Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 69: ...ault the service classes CoS are assigned to the queues as follows COS 0 Queue 0 COS 1 Queue 1 COS 2 Queue 2 COS 3 Queue 3 COS 4 Queue 4 COS 5 Queue 5 COS 6 Queue 6 COS 7 Queue 7 For each value in the CoS column select the queue from the Queue drop down list To apply the settings click Submit To cancel settings click Cancel Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 70: ...r DSCP setting Fig 49 DSCP Mapping Configure the DSCP Mapping settings DSCP Value and Priority Queues Setting Description Factory Default 0 to 7 Maps different types of services values to one of 8 different egress queues 0 8 to 15 1 16 to 23 2 24 to 31 3 32 to 39 4 40 to 47 5 48 to 55 6 56 to 63 7 To apply the settings click Submit To cancel settings click Cancel Anybus Managed Industrial L3 Switc...

Страница 71: ...s that support IGMP 5 13 1 IGMP Query Configure the IGMP Query feature The switch can only be configured by member ports of the management VLAN so the IGMP Query can only be enabled on the management VLAN If you want to run IGMP Snooping feature in several VLANs ensure that each VLAN has its own IGMP Querier The IGMP querier periodically sends query packets to all end stations on the LANs or VLANs...

Страница 72: ... the unknown multicast data flow Multicast Filtering Mode is Flood unknown discard unknown and source only learning Flood Unknown The switch would filter the unknown packets that transmit through the network and the packets will be flooded to the member ports of the same VLAN Discard Unknown Non member ports will not receive the unknown packets because the filter discards the unknown multicast Sou...

Страница 73: ...ows bridges and end stations to dynamically register group membership information with the MAC bridges attached to the same LAN segment and for that information to be disseminated across all bridges in the Bridged LAN that supports extended filtering services Fig 52 GMRP Setting Configure the GMRP settings GMRP Global Setting Select Enable or Disable and click Submit GMRP Port Setting Select to En...

Страница 74: ...destination MAC address so that the traffic can be correctly and smoothly directed to the destination Fig 53 ARP Table Setting Configure the ARP Table settings Aging Time secs Default 14400 seconds Set the Age time for the ARP entry Once there is no packet IP MAC hit the entry within the time the entry will be aged out Short ARP age time leads the entry aged out easier and re learn often the re le...

Страница 75: ...he Status shows Down State Enable or Disable the IP Routing Interface state When disabled the interface work as a layer 2 VLAN When enabled the interface can support IP routing feature IP Address Assign the IP Address for the target IP Interface Subnet Mask Select subnet mask Example 255 255 255 0 represents for the typical Class C or so call 24 bits mask There are 256 IP Addresses within the rang...

Страница 76: ...ter switch is the only setting that need to be specified For the settings to take effect click Apply Static Route Entry Static route entries go to and go from a stub network to another stub network The static route is configured to connect the neighbor router switch Both routers switches then can communicate through the route When configuring the Static Route all the fields in Static Route Entry m...

Страница 77: ...k Reload Route Table When the routing interfaces is changed the system maintains information and updates the routing table Fig 56 Route Table Protocol The field shows the entry is a local interface or learnt from the routing protocol The connected represents for the local interface The OSPF shows the entry is learnt from the routing protocol OSPF Destination The destination address of static route...

Страница 78: ...events routing loops by implementing a limit on the number of hops allowed in a path from source to destination RIP can be used to automatically build up a routing table RIP Setting Fig 57 RIP Setting Configure the RIP Settings RIP Protocol Choose the RIP protocol Version 1 or Version 2 or Disable RIP protocol in here To apply RIP protocol setting click Submit Routing for Networks All networks dir...

Страница 79: ...gure the RIP Interface settings Interface The IP interface RIP Version RIP version of IP interface RIPv1 RIPv2 or Both To apply the settings click Submit To reload the RIP interface configuration click Reload Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 80: ...outers switches to the same broadcast domain The lowest Router ID will be selected as the Designated Router in the network To apply the settings click Submit Routing for Network All the Area ID of the router switch within the same area should use the same IP address or ID All the network addresses should be added Routing for Network Enter the Network Address and the Area ID and click Add To delete...

Страница 81: ...designated router for a network The default is 1 The range is 0 to 255 Transmit Delay The transmit delay timer of this link Interface Transmit Delay is the estimated number of seconds to wait before sending a link state update packet The default value is 1 second Hello The Hello timer of this link Interface The value must be the same for all routers switches on a network The default value is 10 se...

Страница 82: ... of a single Area environment When there are multiple areas in the network you can modify the Area information and Virtual Link Fig 61 OSPF Area Setting Configure the OSPF Area settings Area This field indicates the area ID Select the ID you want to modify Default Cost The default cost of the area ID Shortcut No Defined Disable Enable This indicates whether the area is the OSPF ABR shortcut mode S...

Страница 83: ...Priority Show the priority of the link State While the State is changed to Full which means the exchange progress is done Dead Time The activated time of the link IP Address Shows the learnt IP interface of the next hops Interface Shows the connected local interface To reload the information click Reload OSPF Database Fig 63 OSPF Database Page To reload the information click Reload Anybus Managed ...

Страница 84: ...er and become active if the master router fails VRRP Setting Create the Virtual Router Interface All nodes within the same VRRP domain should be located within the same IP network and equips with the same Virtual ID and Virtual IP address Fig 64 VRRP Setting Virtual Router Configure the Virtual Router settings Interface Select the interface for the VRRP domain VirtualID This is a virtual ID range ...

Страница 85: ...face is the VRRP Master the interface will be recovered If the Preempt is Disable and the interface is VRRP Master there is no change while the link is recovered The VRRP backup acts as the Master before restarting the switches To apply the settings click Submit Selected To delete the setting click Remove To reload the information click Reload VRRP Status To further ensure the high reliability of ...

Страница 86: ...IB tables Default community string is Private The switch allows users to assign 4 community strings To assign a community string enter a string and select the privilege To apply the settings click Submit To delete the setting select the checkbox and click Remove 5 15 2 SNMP V3 Setting SNMP V3 provides network monitoring and control through SNMP protocol that provides secure access to devices by a ...

Страница 87: ...nction with a 128 bit hash value SHA Secure Hash Algorithm hash functions refer to five Federal Information Processing Standard approved algorithms for computing a condensed digital representation Authentication Password Enter the SNMP v3 user authentication password DES Password Enter the password for SNMP v3 user DES Encryption To add a the settings click Add To delete the settings click Remove ...

Страница 88: ...tation as a trap manager assign an IP address enter the SNMP community strings and select the SNMP trap version SNMP Trap Default Disable Enable or Disable SNMP Trap and click Submit Server IP Enter the IP address of the trap manager Community Enter the community string for the trap station Version Select the SNMP trap version type v1 or v2c To add a the settings click Add To delete the settings c...

Страница 89: ...ng access on a specific port only to users with specific MAC addresses The MAC Filter feature stops the MAC address learning for a specific port After stopping MAC learning only the MAC address listed in the list can access the switch and transmit receive traffic This is a simple way to secure User network environment MAC Filter Group Fig 69 MAC Filter Group To add a MAC Filter Group enter a name ...

Страница 90: ...nation MAC Address of the packet Destination Wildcard The mask of the MAC Address Egress Port The outgoing exiting port number Action The filter action which is to deny or permit the packet Permit Permit traffic from specified sources Deny Deny traffic from those sources To add a the settings click Add To delete the setting click Delete IP Filter Fig 70 IP Filter Anybus Managed Industrial L3 Switc...

Страница 91: ...ort The destination port of L4 protocol TCP UDP Egress Port The outgoing exiting port number Action This is the filter action which is to deny or permit the packet Permit to permit traffic from specified sources Deny to deny traffic from those sources To add a the settings click Add IP Filter List Fig 71 View the IP Filter settings Select Selected the entry for delete To delete the setting click D...

Страница 92: ...at needs to be attached the filter MAC Filter Select a MAC address based filter to attach to the interface IP Filter Select an IP address based filter to attach to the interface To apply the settings click Submit Filter Attach List Filters attached to the ports on the switch View Filter Attach List Port The port number MAC Filter The filter attached MAC address IP Filter The filter attached IP add...

Страница 93: ...so provides more security because it only allows traffic transmitting on authenticated ports or MAC addresses Radius RADIUS is used in the authentication process Database of authorized users is maintained on a RADIUS server Allowing or denying the requests decides if the client can connect to a LAN WAN or not 802 1X Setting IEEE 802 1X is the protocol that provides authentication to obtain access ...

Страница 94: ...it Radius Server IP The IP address of Radius server Shared Key It is the password for communicate between switch and Radius Server Server Port UDP port of Radius server Accounting Port Port for packets that contain the information of account login or logout Secondary Radius Server IP Secondary Radius Server could be set in case of the primary radius server down 802 1X Local User Add Account Passwo...

Страница 95: ...ver or Local user list you need to configure the authentication mode authentication behavior applied VLAN for each port and permitted communication Fig 74 802 1X Port Setting Fig 75 802 1X Timeout Setting Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 96: ... to this port set the Host Mode to single means only the first PC authenticate success can access this port If this port is set to multi all the devices can access this port once any one of them pass the authentication Admin Control Direction Determined devices can end data out only or both send and receive Re Auth Period Control the Re authentication time interval 1 65535 are available Quiet Peri...

Страница 97: ...the port status for Port control Authorized Status Authorized Supplicant and Open Control Direction from each port Fig 76 802 1X Port Status To reload the information click Reload Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 98: ...Monitoring port link down event Ring Ring failure If ring topology changed Ping Failure 1 IP Address remote device s IP address If target IP does not reply ping request the relay is active Ping Failure 2 IP address remote device s address Restart Period duration of output open Hold Period duration of Ping hold time Ping target device and trigger relay to emulate power reset for remote device if re...

Страница 99: ...ted Device Warm Start Reboot the device by CLI or Web UI Authentication failure An incorrect password SNMP Community String is entered Time Synchronize Failure Accessing to NTP Server is failure Power 1 2 Failure Power input failure Relay Output 1 Digital Output is on DI 1 Change Digital Input change Ring Event Ring Status has changed or backup path is activated SFP Event SFP transceiver state is ...

Страница 100: ...System Event settings Up The port is connected to another device Down The port is disconnected Both Link status is changed To apply the settings click Submit To cancel the settings click Cancel Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 101: ...selected events in the Event Selection page to Syslog table of the switch Remote Mode In this mode User should assign the IP address of the Syslog server Then the selected occurred events will be sent to Syslog server User assigned Both Both Local Mode and Remote Mode are enabled To apply the settings click Submit To cancel the settings click Cancel Anybus Managed Industrial L3 Switch User Manual ...

Страница 102: ...he email Server address Authentication Click on check box to enable password User Name Enter email Account name Max 40 characters Password Enter the password of the email account Confirm Password Re type the password of the email account Email 1 To The first email address to receive email alert from the switch Max 40 characters Email 2 To The second email address to receive email alert from the sw...

Страница 103: ...is Enabled the neighbor ID and IP learned from the connected devices are automatically shown LLDP Timer Default 30 seconds The interval time of each LLDP and counts in second Valid number is from 5 to 254 LLDP Hold time Default 120 seconds Local port Current port number that linked with neighbor network device Neighbor ID The MAC address of neighbor device on the same network segment Neighbor IP T...

Страница 104: ...nd click Submit Static Unicast MAC Address and Static Multicast MAC Address In some applications the static Unicast MAC address to its MAC address table must be entered Enter the address and click Add MAC Address Table Use the MAC address table to ensure the port security The MAC Address Table can be shown based on the MAC Address Type and based on the Port To delete an address select the checkbox...

Страница 105: ...atistics that can be viewed include Link Type Link State Rx Good Rx Bad Rx Abort Tx Good Tx Bad and Collision Fig 84 Port Statistics To clear the settings select the port checkbox and click Clear Selected To clear all settings click Clear All To reload the information click Reload Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 106: ...cated at the Destination Port Fig 85 Port Mirror Configure the Port Mirror settings Port Mirror Enable or Disable the Port Mirror Source Port The ports to be monitored The traffic of all source ports will be duplicated to the destination ports Select a single port or multiple ports To select the source ports click on the Port ID RX Tx or Both checkbox Destination Port Analyze the traffic of all th...

Страница 107: ... based on how the current time is set in the Basic Setting page Event Log The occurred events To clear settings click Clear To reload the information click Reload 5 18 6 Ping The Ping utility in the management interface is a tool used to troubleshooting network problems and to check if the remote device is alive or not Fig 87 Ping To start the ping enter the Destination IP address of the target de...

Страница 108: ... Green blinking Firmware updating Off Not Ready Ring Ring status Green On Not Owner Normal Green blinking Owner Normal Amber On Abnormal Amber blinking Ring Port Failure Off Ring is disabled DO Alarm Red On Any failure in port link ping power DO or DI State by SW control Off No failure occurs DI Digital Input Green On Detected Digital Input Off No Digital Input 6 2 Ethernet LED Indicators Fig 89 R...

Страница 109: ...On Link Speed 1 Gbit s Amber Off Link speed 100 Mbit s 6 3 SFP Port LED Indicators Fig 90 SFP Port LED Indicators 4 port 100 1000 Base SFP DDM LED Status Description SFP Port Green On Link established Green blinking Packets transmitting receiving Green Off Link is inactive Amber On Link Speed 1 Gbit s Amber Off Link speed 100 Mbit s Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 ...

Страница 110: ...Backup and Restore configuration to save and load the switch configuration 7 2 1 Web Backup and Restore Fig 91 Web Backup and Restore To restore settings Click Choose File and browse the target folder then select the configuration file and click Upload To back up settings in a configuration file Click Save and browse where to save the file Anybus Managed Industrial L3 Switch User Manual SCM 1202 1...

Страница 111: ...odified add remove the configuration settings and then restored back to the switch Action Select Load or Save configuration Click Submit 7 2 3 USB Backup and Restore In the USB Mode you can Load Setting from File or Save Setting to USB File format conf Fig 93 USB Backup and Restore Connect a USB memory to the switch To restore the settings from a configuration file Click Restore and then browse an...

Страница 112: ...94 Web Firmware Upgrade To upgrade the firmware 1 Click Choose file and browse the target folder 2 Select the firmware upgrade file and click Open 3 To start the firmware upgrade click Upgrade 7 3 2 TFTP Firmware Upgrade In the TFTP Server mode the switch acts as TFTP client Fig 95 TFTP Firmware Upgrade Upgrade the firmware 1 Ensure that the TFTP server is ready 2 Enter the TFTP Server IP address ...

Страница 113: ...the Selected File menu 3 Click Upgrade 7 4 Reset To Default Restore the switch to factory default settings Procedure To load the default settings 1 Click Reset 2 A pop up message appears click OK to accept 3 In the web interface top menu click Reboot 4 To reboot the switch click OK Result For the changes to take effect the system auto reboots the switch Anybus Managed Industrial L3 Switch User Man...

Страница 114: ...t the switch is powered on 2 Use a pointed object such as a ballpoint pen to press and hold the reset button for 10 seconds Result Once the reset button is released the switch reboot automatically When the switch has successfully rebooted the SYS LED turns green Anybus Managed Industrial L3 Switch User Manual SCM 1202 151 1 1 en US ...

Страница 115: ... filter HTTPs SSH secure login Redundancy Rapid Spanning Tree Protocol RSTP Multiple Spanning Tree Protocol MSTP ITU T G 8032 v1 v2 Ethernet Ring Protection Switching ERPS Virtual Router Redundancy Protocol VRRP L3 Routing Static Dynamic IP Routing VLAN Routing RIP v1 v2 OSPF v1 v2 IGMP and Multicast Routing Traffic Management Flow Control Port Trunk 802 3ad LACP VLAN Private VLAN GVRP GMRP QinQ Q...

Страница 116: ...This page intentionally left blank ...

Страница 117: ...n the subscriber LAN can be connected to the same port on the access switch and are uniquely identified The Option 82 information contains 2 sub options Circuit ID and Remote ID which define the relationship between the end device IP and the DHCP Option 82 server The Circuit ID is a 4 byte number generated by the Ethernet switch a combination of physical port number and VLAN ID Anybus Managed Indu...

Страница 118: ...ACP operation requires full duplex mode Static mode is still necessary because some devices only support static trunk B 1 Port Trunk Concept Port trunking protocol that provides the following benefits Flexibility in setting up User network connections since the bandwidth of a link can be doubled tripled or quadrupled Redundancy if one link is broken the remaining trunked ports share the traffic wi...

Страница 119: ...ess to validate the health of the service instance Continuity Check Protocol CCP Heartbeating messages for CFM The Continuity Check Message CCM provides a means to detect connectivity failures in an MA CCMs are multicast messages CCMs are confined to a domain MD These messages are unidirectional and do not solicit a response Each MEP transmits a periodic multicast Continuity Check Message inward t...

Страница 120: ...cable D 1 Spanning Tree Protocol STP STP is a Layer 2 link management protocol that provides path redundancy while preventing loops in the network For a Layer 2 Ethernet network to function properly only one active path can exist between any two stations Spanning tree operation is transparent to end stations which cannot detect whether they are connected to a single LAN segment or a switched LAN o...

Страница 121: ... Spanning Tree IST is used to connect all the MSTP switches within an MST region An MST Region may contain multiple MSTP Instances MSTP connects all bridges and LAN segments with a single Common and Internal Spanning Tree that is formed as a result of the running spanning tree algorithm between switches that support the STP RSTP MSTP protocols To configure the MSTP setting the STP Mode of the RSTP...

Страница 122: ...et Ring Nodes that participating in the same Ethernet Ring using two independent links In the Ethernet ring loops can be avoided by guaranteeing that traffic may flow on all but one of the ring links at any time This particular link is called Ring Protection Link RPL A control message called Ring Automatic Protection Switch R APS coordinates the activities of switching on off the RPL Under normal ...

Страница 123: ...n of a VLAN into subdomains allowing User to isolate the ports on the switch from each other A subdomain consists of a primary VLAN and one or more secondary VLANs All VLANs in a private VLAN domain share the same primary VLAN The secondary VLAN ID differentiates one subdomain from another The secondary VLANs may either be isolated VLANs or community VLANs A host on an isolated VLAN can only commu...

Страница 124: ...te advertisements LSAs to its neighbor routers routing switches When compared with Routing Information Protocol RIP which is a distance vector based routing protocol OSPF can provide scalable network support and faster convergence time for network routing state OSPF is widely used in large networks such as Internet Service Provider ISP backbone and enterprise networks The OSPF is a complex protoco...

Страница 125: ...onitor and manage thousands of systems on a network often by presenting the data gathered from monitored devices in a snapshot or dashboard view SNMP managed network consists of two main components agents and a manager An agent is a management software module that resides in a managed switch An agent translates the local management information from the managed device into a SNMP compatible format ...

Страница 126: ...last page 2020 HMS Industrial Networks Box 4126 300 04 Halmstad Sweden info hms se SCM 1202 151 1 1 en US 2020 02 11 17125 ...

Отзывы: