![ANXELL DG-360+ Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/anxell/dg-360/dg-360_quick-start-manual_2948724002.webp)
◆
Specifications
Note:
1. Make sure that the power input and SSR rating output
(2A/12VDC) are correct.
2. Make sure that the “+” and “-” wires are connected
correctly.
The GDG360BT includes one pair of NO/NC/COM
output contacts, which can directly connect to a
locking device or connect in parallel or series with
access control systems.
* Reed Switch:
◆
Operation Note
P3
P2
P1
P3
P2
P1
P1+P2
P2+P3
* Using Reset Jumper
(Default)
(Reset)
Operating Voltage
12~24VDC
Current Draw
Status
12VDC
24VDC
Standby
Active
90 mA
101mA
46 mA
51mA
Frequency and Storage Format
125 KHz, internal decimal number
(ABA format, decimal conversion)
Read Range
3 cm
Inputs
1 RTE (Request-to-exit)
1 Door sensor (DS)
Outputs
1 SSR (Dry contacts N.O./N.C./COM.)
1 Tamper Alarm (ALM)
Indicator Light
3 LEDs (Red, Green, Blue)
Memeory Volume
1 Administrator & 200 Users
Card Format
EM-400x 64-bit Standard R/O or Compatible
SSR Contact Rating
2A/12VDC
SSR Output Time
1~1800 seconds (adjustable on APP)
Humidity
5%~95% (Non-condensing)
Temperature
-20°C~70°C
Bluetooth Module
BLE 4.2
Auto Proximity Range
0~20 meters (adjustable)
LED & Audible Indicators
Solid Blue LED
Power on, Standby
1 Short beep
Key press
Red LED
Invalid access,
Door always locked
1 Long beep
Buzzer sound
Valid access
Reset completed
Green LED
Unlocked,
Door always unlocked
2 Short beeps
Buzzer sound
Login completed
Continous buzzer sound
Device vandalized
Alarm activated
Flashing Blue LED
Bluetooth connecting
3 Short rapid beeps
3. The door strike or relay must have a varistor or a diode
across the door strike terminals to suppress the back
EMF of the strike.
Failure to do so will damage the relay contacts and
electronic components, or even burn the controller.
Door closed status: NO contact
Door open status: NC contact
2