Detect door-open wire (blue):
Low trigger, for detecting the door-open signal;
Customized trigger (orange, green):
These two wires are for custom self-defined signal detection wire.
(Custom orange negative trigger line should > 0.5V, which to trigger conduction; green line
custom> 6V to trigger conduction.
Electricity Power cut wire control (yellow):
T360-269 of the power control wire (yellow)
is mainly used to meet with the power relay
circuit to cut off the motor fuel or engine
circuit, forced to stop the engine running.
Emergency button:
Basically use for the driver while face an emergency situation,
can trigger the button T360-269 equipment to issued a
distress call to the center information platform. Usually trigger
button does not easily found location.
6.3.3.3.
269A6A Installation instruction (Optional)
269A6A install lines to connect the main characters are text sound broadcast device cable
connector, detailed installation and use please refer to "text sound broadcast installation
instructions" and "platform operating instructions" related to the contents of the operation.
6.3.3.4.
269A4A Installation Instructions (optional)
269A4A installation cable are advertisement LED connector, detailed installation and use
please refer to "LED screen installation instructions “and "platform operating instructions"