synchronization time.
5.1.5 Unit Parameter
Click
【
Device Parameter
】
button open the
【
Terminal parameter settings
】
window:
[Sleep time]: Attendance from unattended to go to sleep interval, 0 means not hibernate,
maximum sleep time was 250 minutes
[Volume]: Attendance voice prompt volume level, 0 represents the mute, the maximum volume
of 5
[Date format]: Attendance in the date format, there are about several formats:
yy-mm-dd(year-month-day), mm/dd/yy(month -day-year), dd/mm/yy(day-month-year)
[Time format]: Attendance, the time display format minute 24-hour and 12-hour two kinds
[Matching precision]: normal, good, exact three levels, the default is good. The higher accuracy
of fingerprint requirements are also higher
[Record alarm threshold value]: When the attendance record set record number is greater than
the alarm threshold value, the machine will prompt the user to make the appropriate alarm
processing. 0 means no alarm, you can set the maximum number of records in 5000.
[Time period between repeated clocking]: The interval between the same user twice
attendance, 0 indicates no interval, the maximum interval is 250 minutes. Attendance during
the interval times, the system records only one record.
[Workcode prompt]: Work code function is enabled and disabled.
[Intelligently update the fingerprint template]
:
Fingerprint comparison on the process, it can
automatically replaces the previous low-quality storage of fingerprint data for the new
high-quality fingerprint data acquisition, thereby maintaining the latest fingerprint data, to avoid
Содержание P7
Страница 1: ... 2001 2015 Anviz Technology Co Ltd P7 PoE Touch Fingerprint and RFID Access Control User Manual V1 0 ...
Страница 6: ...User Manual 5 8 APPENDIX 89 8 1 Communication And Power Interface 89 8 2 Access Wiring Diagram 89 ...
Страница 86: ...User Manual 85 Chapter7 FAQ Frequently asked questions and answers ...
Страница 92: ...User Manual 91 6 Connect P7 With SC011 of Anviz ...