1) Tilt door up at about 45° angle until the Top Hook
on the Hinge Arm is lower than the Top Hook Roller,
2) then pull out of Hinge Slots
Hinge Arm
Top Hook Roller
(2)
(1)
Hinge lock - in
up/locked position
Side of Oven
Rotate the Hinge Lock
to up position (both sides)
(side view)
Step 2
Hinge lock - must be in
up/locked position
Side of Oven
Open the door fully
(side view)
Side of Oven
Hinge lock - in "down/unlocked"
position
Door (fully opened; does not open flat)
Step 1
Step 3
(side view)
The doors can be removed for cleaning.
(Assembly instructions)
MAINTENANCE
Replacement of the internal lamp
1. Disconnect the appliance from the power supply and let it cool
down if hot.
2. Remove the shelf support grid.
3. Unscrew the glass cover and replace the lamp with the correct
specification – 230V/ 25 W or 120V/ 15 W in case of the
COA1001-120 & COA1002-120.
4. Reassemble in the reverse order.
EXPLODED DIAGRAM
MINI PRIMA CONVECTION OVEN
MODEL: COA1002 R01