Antunes DCH-100 Скачать руководство пользователя страница 1

P/N 1010772 Rev. H 05/18

DCH-100/200/300 

DCH-120/220/320

owner’s manual

Toasters Heated

Manufacturing Numbers:

9500500, 9500510, 9500512, 9500520, 

9500530, 9500531, 9500532, 9500533, 

9500534, 9500535, 9500536, 9500537, 

9500538, 9500540, 9500550, 9500551, 

9500552, 9500553, 9500554, 9500556, 

9500557, 9500559

www.antunes.com

Содержание DCH-100

Страница 1: ...20 320 owner s manual Toasters Heated Manufacturing Numbers 9500500 9500510 9500512 9500520 9500530 9500531 9500532 9500533 9500534 9500535 9500536 9500537 9500538 9500540 9500550 9500551 9500552 9500553 9500554 9500556 9500557 9500559 www antunes com ...

Страница 2: ...t Antunes Customer Service immediately at 1 877 392 7856 toll free If there are problems with the instal lation or operation of this product contact Antunes Technical Service toll free at 1 877 392 7854 Fill in the information in the next col umn and have it handy when calling for assistance The serial number is on the specification plate located on the system Content Overview 2 Before Use 2 In Ca...

Страница 3: ...the edge of a table or counter Maintenance y y Do not use abrasive materials they can damage the heated toaster s stainless steel finish y y Do not use corrosive chemicals in this equipment y y Chlorides or phosphates in cleaning agents e g bleach sanitizers degreasers and detergents can permanently damage stainless steel equipment The damage is usually in the form of discoloration dulling of the ...

Страница 4: ...surface covered with a soft cloth to place the glass on if the glass is removed USE a clean soft cloth when cleaning the glass Do not use paper towels USE light pressure when wiping cleaning the glass MAKE SURE that the top cover glass does not touch the edge of the side glass MAKE SURE to replace scratched chipped nicked cracked or broken glass Please follow the Safety Instructions below in order...

Страница 5: ...Tray some models DCH 300 DCH 320 y y Three 2 1 2 63 5 mm deep full size steam table pans y y Two water trays at 5 quarts 4 7 liters each Temperature Ranges DCH 100 150 165 F 66 74 C DCH 120 100 165 F 38 74 C DCH 200 150 165 F 66 74 C DCH 220 100 165 F 38 74 C DCH 300 150 165 F 66 74 C DCH 320 100 165 F 38 74 C Dimensions A B C Model A B C DCH 100 DCH 120 15 1 8 384 mm 30 1 4 768 mm 22 13 32 569 mm...

Страница 6: ... 1800 15 0 50 60 DCH 300CT 9500540 120 1800 15 0 50 60 DCH 320CT 9500550 120 1800 15 0 50 60 DCH 320CT 9500551 120 1800 15 0 50 60 DCH 320CT 9500552 120 1800 15 0 50 50 DCH 320 9500553 International Unit 200 240 2850 14 3 11 8 50 60 DCH 320CT 9500554 120 1800 15 0 50 60 DCH 320HC 9500556 220 240 2800 12 2 50 60 DCH 320CT 9500557 120 1800 15 0 50 60 DCH 320HB 9500559 Saudi Arabia 220 240 2800 12 2 ...

Страница 7: ...rd to hang over edge of table or counter y y Place unit on a sturdy level table or work surface y y Ensure that the line voltage corresponds to the stated voltage on the unit specification label located at the end of the power cord y y Turn the Rocker Switch power On Off to OFF Connect the unit to the power supply Water Tray some models Heating Element Shield THIS UNIT IS DESIGNED TO OPERATE ON 12...

Страница 8: ...ipped with a Crumb Tray Figure 1 are designed to operate WITHOUT water Figure 2 Filling Water Tray DCH 100 shown TEM P UP TEM P DOW N TEM P SCA LE F C O O The Setpoint temperature is the desired cabinet temperature setting When the Temp UP button is pressed and held and provided that the unit is up to temperature the actual cab inet temperature is displayed When the button is released the Setpoint...

Страница 9: ...ean cloth to handle halogen bulbs CAUTION Use 1000 Watt Max Quartz tungsten halogen lamp T4 Bulb RSC Base only To reduce the risk of electric shock when re placing bulbs turn display switch to OFF position 1 Turn the unit off 2 Unplug the power cord from the electrical outlet and allow the unit to cool to room temperature before proceeding 3 Gently but firmly press the lamp socket sideways and rem...

Страница 10: ...d to the rear Figure 8 3 Tilt the Front Glass Panel Assembly forward on the Hinge Plate and remove the panel from the unit 4 To reinstall be sure the Front Glass Panel Assembly is fully seated in the Hinge Plate Then tilt the assembly fully to wards the rear and secure it to the Top Glass Retainer Assem bly using the thumb screws TEMP UP TEMP DOWN TEMP SCALE F C O O Figure 7 Rear Door s Removal In...

Страница 11: ...exceeds the setpoint temperature or if the thermistor has short ed NOTE The thermistor should be 100k ohm 2 at room temperature OPEN flashes if the thermistor is OPEN or discon nected The unit will not call for heat NOTE The thermistor should be 100k ohms 2 at room temperature PO In 120 VAC units this code flashes if the sup ply voltage is below 100 VAC or above 135 VAC In 220 240 VAC units this c...

Страница 12: ...ncy for service Inoperable Control Board Display flashes OPEN and the cabinet does not heat up Thermistor is disconnected or open Re secure the Thermistor onto the Control Board If this problem persists contact your maintenance person or Authorized Service Agency for service Inoperable Control Board Display flashes PO and the cabinet does not heat up For 120 volt units the supply voltage is below ...

Страница 13: ...ement Parts DCH 100 120 47 18 60 50 61 23 22 50 60 59 19 47 27 47 30 28 32 31 33 35 20 12 55 16 49 53 50 49 15 17 11 13 40 44 52 2 42 43 52 3 1 55 52 4 9 9 10 5 6 58 7 57 63 21 48 37 64 36 62 8 45 51 34 14 65 56 25 50 39 38 65 26 66 67 ...

Страница 14: ...lement 120V 1400 Watts 1 39 7000369 Thermistor Replacement Kit 1 40 0503037 Duct Access Cover 1 42 4060252 Bulb Quartz Halogen 100 Watt 1 43 4060189 Bulb Holder Quartz 2 Item No Part Description Qty 44 0800316 Guard Lamp 1 45 0400251 Strain Relief w Locknut 1 47 306P101 Nut Hex 6 32 SS 1 48 306P105 Screw 6 32 x 1 2 SS 1 49 306P130 Nut Hex KEPS 6 32 1 50 308P103 Screw 8 32 x 1 4 6 51 308P124 Screw ...

Страница 15: ...acement Parts DCH 200 220 53 64 46 45 53 48 54 25 26 20 58 21 24 50 18 68 12 16 56 52 15 17 11 13 35 42 43 55 41 10 58 55 50 6 4 55 40 44 2 3 7 19 52 67 31 32 33 34 30 29 68 62 14 5 22 59 1 39 38 70 37 36 69 27 71a 67 23 71b 66 65 9 ...

Страница 16: ...al Block 8 Pole 2 2 2 2 20 0504070 Retainer Glass see Note 1 2 2 2 2 21 0011718 Top Cap Assy LH see Note 1 1 1 1 1 0011717 Top Cap Assy RH see Note 1 1 1 1 1 22 2100183 Door Track Upper 1 1 1 1 23 2100184 Door Track Lower 1 1 1 1 24 0501946 Grill Blower some models 1 1 25 0700451 Power Cord w Plug NEMA 5 20P 120V 1 1 0700453 Power Cord w Plug CEE 7 7 240V 0700556 Power Cord Assembly UK 9500537 Onl...

Страница 17: ...r Tray some models 67 2180179 Side Glass Nylon Stopper 2 2 2 2 68 306P123 Screw 6 32 x 7 8 1 1 1 1 69 7000174 Blower Cage Bearing Grommet Kit 1 1 1 1 70 213K103 Full Size Pan 2 1 2 deep Non perforated optional 71 002K853 Pan Adapter Insert optional accommodates two optional 4 deep full size pans 0021348 Pan Adapter Insert Sloped Version Optional Only available in packages of 10 LH RH is determined...

Страница 18: ...6 45 12 16 56 52 15 17 11 13 42 43 55 41 9 69 58 6 4 55 40 44 2 3 7 5 1 39 70 23 7 20 58 22 24 66 53 48 54 25 5018 65 34 31 32 33 29 30 50 37 66 36 35 52 19 35 52 71 71 14 21 34 55 67a 67b 10 65 62 38 8 Replacement Parts DCH 300 320 ...

Страница 19: ... No 9500554 556 2 4000194 Blower Motor Mfg No 9500553 1 36 0200155 Magnetic Strip 2 37 5040028 Base Hinge Assy 1 38 4030304 Heating Element 120V 500 Watts 3 4030239 Heating Element 230 Volts 825 Watts 3 39 7000369 Thermistor Kit 1 40 0501865 Duct Access Cover 1 Item No Part Description Qty 41 0502556 Deflector Heat 1 42 4060252 Bulb Quartz Halogen 100W 2 43 4060189 Bulbholder Quartz 4 44 0800229 G...

Страница 20: ...MINAL 1 2 5 4 WHT WHT WHT WHT BLK SWITCH POWER GRN YEL GRN WHT BLU BLK BRN WHT BLK WHT BLK WHT BLK DISPLAY LAMPS THERMISTOR HEATER QUARTZ LAMP BLK BLK YEL YEL YEL YEL RED BLK WHT BLK TRANSFORMER WHT BLK 4 3 S S RELAY 1 2 BLK WHT WHT BLK BLK TEMPERATURE CONTROLLER T5 T1 T2 T3 T4 T9 T7 T8 RESISTOR RESISTOR BLK WHT BLK BLK BLK LAMP QUARTZ WHT BLOCKS TERMINAL GRN BLOCK 1 TERMINAL GND CORD POWER 14 GA ...

Страница 21: ...T GRN BLOCK 1 TERMINAL GND CORD POWER 14 GA TFE 200 18 GA TFE 200 BLOCKS TERMINAL DCH 320 230 Volt Units WHT WHT WHT BLOCKS TERMINAL WHT BLK GRN SWITCH POWER BLOCK 1 TERMINAL GND GRN YEL GRN WHT BLU BLK BRN CORD POWER WHT BLK WHT BLK WHT BLK DISPLAY LAMPS THERMISTOR HEATER QUARTZ LAMP BLK BLK YEL YEL YEL YEL RED BLK WHT BLK TRANSFORMER WHT BLK 4 3 S S RELAY 1 2 BLK WIRING DIAGRAM 14 GA TFE 200 18 ...

Страница 22: ...r this warranty and is the responsibility of the end user 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a warranty charge 3 If shipment is damaged in transit the purchaser should make a claim ...