Troubleshooting

Error Codes

This section describes the error codes that may appear on the display.

NOTE:

 For the errors below, attempt to turn the unit off and turn it back on again to see if the problem is fixed. If 

the problem persists, contact Antunes Technical Service at +1-877-392-7854 (toll free) for assistance.

Error 

Code

Error

Description

Action

‘2’

ZERO CROSS 

Internal control board error

Cycle Power OFF Unplug unit for 30 seconds Cycle Power ON . If 

message persists, contact Antunes Technical Support at +1-877-392-7854 

(toll free) for assistance.

‘6’

MEMORY

Memory chip error.

‘105’

OVER TEMP

Temperature on Top Platen is 25°F over Set 

Point Temperature.

106

OVER TEMP

Temperature on Bottom Platen is 25°F over Set

Point Temperature.

‘111’

UNDER TEMP

Top Platen drops 100°F below Set Point 

Temperature when in USE state.

112

UNDER TEMP

Bottom Platen drops 100°F below Set Point 

Temperature when in USE state.

‘135’

WARMUP TIME

Top Platen is taking too long to warm-up.

136

WARMUP TIME

Bottom Platen is taking too long to warm-up.

‘5’

I2C TIMEOUT

Control board hardware failure.

Power cycle the unit. If error persists, contact Antunes Technical Service at 

+ 1-877-392-7854. 

‘9’

BOARD 

TEMPERATURE 

Internal air temperature of unit is too high 

and the system is powering down to prevent 

damage.

Check for vent blockages and adequate spacing for ventilation around 

unit.   Contact Antunes Technical Service at + 1-877-392-7854

‘101’

HI-LIMIT

Hi-Limit is triggered.

Allow sufficient time (10-15 minutes) for the unit to cool down. Remove the 

Hi-Limit control cap at the rear of the unit. Press the Hi-Limit Reset button.  

Turn the unit on and test the unit. If the Hi-Limit continues to trip, contact 

Antunes Technical Service at +1-877-392-7854 for assistance.

‘117’

OPEN PROBE ON 

TOP PLATEN

Thermocouple connection is open on Platen.

Re-secure the Platen Thermocouple connection to the proper Control 

Board. If the Control Display still reads “Open Probe” If message persists, 

contact Antunes Technical Support at +1-877-392-7854 (toll free) for 

assistance.

‘118’

OPEN PROBE ON 

BOTTOM PLATEN

‘129’

TOP PLATEN SOLID 

STATE RELAY

SSR has shorted, the wiring between SSR and 

heater has shorted, or the control board has 

failed. 

Technician is required for repair and/or replacement. Contact Antunes 

Technical Support at +1-877-392-7854 (toll free) for assistance.

‘130’

BOTTOM PLATEN 

SOLID STATE 

RELAY

‘141’

TOP PLATEN OPEN 

HEATER

SSR is open, there is an open in the wiring 

between the SSR and heater, there is a failure 

of the heater inside the Platen, or the control 

board has failed.

‘142’

BOTTOM PLATEN 

OPEN HEATER

Hi Limit Control

If the Hi Limit trips, the display will 

show:

 

y

E101 Hi-Limit

A tripped Hi Limit shuts off power to 

the unit. To reset a tripped Hi Limit 

switch:

1. 

Allow the unit to cool for 10 - 15 

minutes.

2. 

Turn the unit back on.

 

Factory Reset

If the unit requires a Factory Reset, 

contact Antunes Technical Service at 

+1-877-392-7854 (toll free). 

Содержание 9800208

Страница 1: ... Tortilla Warmer Owner s Manual Model TW 100 www antunes com Manufacturing Number 9800208 CAUTION Read all instructions before using the unit Original Instructions P N 1011561 Rev A 01 20 ...

Страница 2: ...y parts are missing or damaged problems with the installation or operation of this product contact Antunes Customer Service immediately at 1 877 392 7856 toll free Fill in the information in the next section and have it ready when calling for assis tance The serial number is on the specifi cation sticker located on the system Equipment Information to Save Purchased from Date of purchase Model numb...

Страница 3: ...ore toasters must not be used near or below curtains or other combustible walls and materials Failure to maintain safe operating distances may cause discoloration or combustion y y Start Stop Buttons The stop button DOES NOT break the connection fron the mains The main power connector at the apparatus must remain accessible y y Mains Disconnect The plug shall remain readily operable For installati...

Страница 4: ...igurations Model Mfg No Description Configuration TW 100 9800208 NEMA 6 15P 250 Volts 15 Amps Model Mfg No Volts Watts Amp Hertz TW 100 9800208 208 240 1800 7 5A 50 60 Model Mfg No Width A Depth B Height C Height Open D TW 100 9800208 18 46 cm 24 60 cm 8 20 cm 20 51 cm Dimensions A B C D ...

Страница 5: ...protective coverings NOTE Do not tip the warmer as the unit will spring open and become unstable 4 Wipe all surfaces of the unit with a hot damp cloth Do NOT use a dripping wet cloth Wring it out before use 5 Clean the accessories in hot soapy water Rinse in clear water and allow to air dry 6 Reassemble the unit 7 The unit must be level before use 8 Attach the power cord to a grounded receptacle F...

Страница 6: ... place tortilla s onto and to remove tortilla s from the warmer Controls The following controls and indicators are available on the control panel 1 Power Button y y Powers the unit on Push and hold power button for at least 2 seconds to power on or off the unit 2 LED Display y y Shows the current status of the Tortilla Warmer y y Error messages will be displayed on the LED Display See the Troubles...

Страница 7: ...ure before performing any service or maintenance Do not attempt to clean the unit at temperatures over 220 F 100 C to avoid personal injuries and warpage to the heater surface WARNING Never immerse or pour water over the Tortilla Warmer Do not clean Tortilla Warmer with a water jet CAUTION Chlorides or phosphates in cleaning agents e g bleach sanitizers degreasers or detergents can cause permanent...

Страница 8: ...on around unit Contact Antunes Technical Service at 1 877 392 7854 101 HI LIMIT Hi Limit is triggered Allow sufficient time 10 15 minutes for the unit to cool down Remove the Hi Limit control cap at the rear of the unit Press the Hi Limit Reset button Turn the unit on and test the unit If the Hi Limit continues to trip contact Antunes Technical Service at 1 877 392 7854 for assistance 117 OPEN PRO...

Страница 9: ... P N 1011561 Rev A 01 20 9 Wiring Diagram ...

Страница 10: ...manufacturer will void the warranty Item No Part Description Qty 48 2180625 Platen Cover Edging 1 49 3010101 Nut Spotweld 08 32 4 40 x 25 LG Pan HD PHL S S 2 50 3010193 7 16 14 x 2 5 LG Set Screw Cup Point 1 51 3030167 Handle Pivot Shaft 1 52 3030168 Handle Pivot Pin 2 53 3040105 Nut Hex KEPS 4 40 Zinc 9 55 3040131 Stud Self clinching 4 40 X 3 8 5 56 3040156 4 40 x 25 LG PAN HD PH Nylon 2 57 30601...

Страница 11: ...1 Rev A 01 20 11 Exploded Views Exploded View 1 15 26 61 61 60 29 23 18 48 19 10 76 74 49 10 4 3 11 37 71 12 18 89 19 61 49 76 16 74 88 70 89 13 81 70 17 61 21 61 7 31 92 32 91 65 92 93 94 96 39 40 45 52 52 63 63 ...

Страница 12: ...1 Rev A 01 20 12 REPLACEMENT PARTS Exploded View 2 86 54 38 30 53 84 57 78 80 83 55 53 58 22 61 75 25 61 59 85 56 6 79 28 66 69 69 5 24 43 9 34 36 36 34 14 69 77 27 35 41 64 46 73 44 1 72 20 50 33 51 47 67 68 2 9 ...

Страница 13: ... P N 1011561 Rev A 01 20 13 NOTES ...

Страница 14: ...ed service agency 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a warranty charge 3 If shipment is damaged in transit the purchaser should make a claim directly upon the carrier Careful inspec...

Отзывы: