SCALE INHIBITOR SYSTEM (P/N 9700901)
+1-877-392-7854
Page 2 of 2
P/N 1010449 Rev. B 07/17
INLET WATER PLUMBING
The plumbing leading to the Scale Inhibitor System must be
flushed clear of all debris before connecting to the inlet connec-
tion of a water system. Hold a bucket at the inlet water line and
slowly open the inlet water valve. Allow the pipe to flush until all
debris is removed.
MOUNTING THE SYSTEM
Before mounting the Scale Inhibitor System, please consider the
items listed below:
• The Housing must be mounted with sufficient access for
element replacement. The Housing is 14 inches tall. An
additional 2 inches should be allowed below the clear bowl
to allow proper access when changing elements.
• The kit must be mounted with hardware capable of support-
ing 10 lbs or more of weight.
• The mounting bracket supplied with the system must be
mounted in the UP position (See Figure 2). The bracket
comes with short screws for attaching to the head and long
screws for attaching the bracket to the wall.
NOTE: Only the short screws should be used for mounting
the Head to the Bracket.
• The Head can be mounted with the inlet on the left or on
the right. When the inlet is on the left, the red pressure
relief button is on the left. Refer to Figure 2 for help in locat-
ing the Inlet and Outlet ports.
• The Scale Stick Inhibitor System kit must be installed
upstream of all consumable water access points.
• The inlet water should only be connected to the “INLET”
port on the Head. The filtered water should only be con-
nected to the “OUTLET” port on the Head. See Figure 2.
Attach the mounting bracket to the Head
BEFORE
attaching to
the wall.
ATTACHING TO THE INLET
Both the Inlet and Outlet connections have a 3/4” NPT female
thread. Be careful not to overtighten a fitting into the Head.
Plastic fittings are recommended for connecting to the Head.
Use a pipe thread sealant approved for use in drinking water
applications with plastic fittings.
Sanitizing the System and Lines
INLET
OUTLET
Red Pressure
Relief button
Attach Bracket to
Wall in this position
Figure 2. Mounting Bracket (Up Position ONLY)
CAUTION
DO NOT connect the Inlet water to the Outlet port
on the head.
The plumbing must be sanitized to eliminate possible contami-
nation that may have occurred during the installation process.
Liquid chlorine bleach (regular bleach, unscented 6% sodium
hypochlorite) can be used to sanitize the plumbing. The amount
of bleach to use depends on the system installed and the
amount of plumbing downstream of the Scale Inhibitor System.
Generally 10 drops (one-half ml) of bleach is sufficient to sani-
tize the bowl and associated plumbing.
CAUTION
Make sure the follow any handling or safety instructions
supplied with the bleach.
NOTE: When sanitizing the Scale Inhibitor System, make
sure the Scale Inhibitor element is not installed or is
removed from the housing before sanitizing.
1. Direct the water line from the outlet of the Head to a
drain.
2. Unscrew the Housing counter clockwise to remove the
Housing from the Head.
3. Pour the liquid chlorine bleach into the bowl.
4. Screw the Housing (containing the bleach) into the Head.
Tighten the bowl until it stops. The Housing will come to a
hard stop at the end of the thread. Use the filter wrench if
necessary.
5. Slowly turn on the water supply and pressurize the sys-
tem. Allow water to flow out of the Housing until the odor
of bleach is present.
6. Turn off the water supply and let the system stand without
water flow for at least 15 minutes to allow the bleach to
sanitize the pipes.
7. After 15 minutes without water flow, turn on the water
supply and flush until the presence of bleach is gone.
8. Shut off the water supply and depressurize the system.
NOTE: Refer to document 1010448, provided with this sys-
tem, for instructions on replacing and rinsing the Scale
Inhibitor Kit.
ANTUNES
www.antunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188