SCALE INHIBITOR SYSTEM (P/N 9700901)

+1-877-392-7854 

Page 2 of 2 

P/N 1010449 Rev. B 07/17 

INLET WATER PLUMBING

The plumbing leading to the Scale Inhibitor System must be 

flushed clear of all debris before connecting to the inlet connec-

tion of a water system. Hold a bucket at the inlet water line and 

slowly open the inlet water valve. Allow the pipe to flush until all 

debris is removed.

MOUNTING THE SYSTEM

Before mounting the Scale Inhibitor System, please consider the 

items listed below:

•  The Housing must be mounted with sufficient access for 

element replacement. The Housing is 14 inches tall. An 

additional 2 inches should be allowed below the clear bowl 

to allow proper access when changing elements.

•  The kit must be mounted with hardware capable of support-

ing 10 lbs or more of weight.

•  The mounting bracket supplied with the system must be 

mounted in the UP position (See Figure 2). The bracket 

comes with short screws for attaching to the head and long 

screws for attaching the bracket to the wall.

NOTE: Only the short screws should be used for mounting 

the Head to the Bracket.

•  The Head can be mounted with the inlet on the left or on 

the right. When the inlet is on the left, the red pressure 

relief button is on the left. Refer to Figure 2 for help in locat-

ing the Inlet and Outlet ports. 

•  The Scale Stick Inhibitor System kit must be installed 

upstream of all consumable water access points.

•  The inlet water should only be connected to the “INLET” 

port on the Head. The filtered water should only be con-

nected to the “OUTLET” port on the Head. See Figure 2.

Attach the mounting bracket to the Head 

BEFORE

 attaching to 

the wall. 

ATTACHING TO THE INLET

Both the Inlet and Outlet connections have a 3/4” NPT female 

thread. Be careful not to overtighten a fitting into the Head. 

Plastic fittings are recommended for connecting to the Head. 

Use a pipe thread sealant approved for use in drinking water 

applications with plastic fittings.

Sanitizing the System and Lines

INLET

OUTLET

Red Pressure 

Relief button

Attach Bracket to 

Wall in this position

Figure 2. Mounting Bracket (Up Position ONLY)

CAUTION

DO NOT connect the Inlet water to the Outlet port  

on the head.

The plumbing must be sanitized to eliminate possible contami-

nation that may have occurred during the installation process.

Liquid chlorine bleach (regular bleach, unscented 6% sodium 

hypochlorite) can be used to sanitize the plumbing. The amount 

of bleach to use depends on the system installed and the 

amount of plumbing downstream of the Scale Inhibitor System. 

Generally 10 drops (one-half ml) of bleach is sufficient to sani-

tize the bowl and associated plumbing. 

CAUTION

Make sure the follow any handling or safety instructions 

supplied with the bleach.

NOTE: When sanitizing the Scale Inhibitor System, make 

sure the Scale Inhibitor element is not installed or is 

removed from the housing before sanitizing.

  1.  Direct the water line from the outlet of the Head to a 

drain.

  2.  Unscrew the Housing counter clockwise to remove the 

Housing from the Head.

  3.  Pour the liquid chlorine bleach into the bowl.

  4.  Screw the Housing (containing the bleach) into the Head. 

Tighten the bowl until it stops. The Housing will come to a 

hard stop at the end of the thread. Use the filter wrench if 

necessary.

  5.  Slowly turn on the water supply and pressurize the sys-

tem. Allow water to flow out of the Housing until the odor 

of bleach is present.

  6.  Turn off the water supply and let the system stand without 

water flow for at least 15 minutes to allow the bleach to 

sanitize the pipes.

  7.  After 15 minutes without water flow, turn on the water 

supply and flush until the presence of bleach is gone.

  8.  Shut off the water supply and depressurize the system.

NOTE: Refer to document 1010448, provided with this sys-

tem, for instructions on replacing and rinsing the Scale 

Inhibitor Kit.