Antunes 9700901 Скачать руководство пользователя страница 1

SCALE INHIBITOR SYSTEM (P/N 9700901)

+1-877-392-7854 

Page 1 of 2 

P/N 1010449 Rev. B 07/17 

TOOLS:  

• Mounting Hardware (Not Provided) 

• Drill with bits 

• Tape Measure 

• Pipe Wrenches 

• Adjustable Wrenches 

• Level 

• Pipe Dope, Thread Seal Tape, or Thread Sealing Cord 

• Screwdriver (Flat Blade and Phillips) 

• Two Gallon Bucket 

• Fresh 6% unscented liquid chlorine bleach

PARTS INCLUDED: 
1 - Bracket, Filter Std. Housing w/ screws (P/N 0505639)

1 - Housing, Bowl, and Head (2180243)

1 - Wrench, Filter (2180244)

1 - Tee 3/4” NPT (2190130)

1 - Nipple, Hex 3/4” NPT x 1-1/2” LG (2190144)

1 - Scale Inhibitor Element Kit (7000540) 

1 - Scale Inhibitor System Instruction Sheet (P/N 1010449)

CAUTION

Do not use this system with water that is microbiologi-

cally unsafe or of unknown quality without adequate dis-

infection installed before or after the system.

General

If you experience any problems with these instructions, or if 

any parts are damaged or missing, contact Antunes Technical 

Service at +1-877-392-7854 (toll-free).
The Scale Inhibitor System provides mineral scale prevention 

by feeding scale control compounds into the water. It should be 

installed upstream of any ice making, beverage, or steam equip-

ment.

Equipment Setup

When installing the system, pay attention to the following guide-

lines:

•  Do not install above electrical equipment.
•  Allow space below the Scale Inhibitor Housing for Element 

change out.

PLUMBING
NOTE: This system is designed to be used on tap water not 

to exceed 100°F (38°C) or 100 psig (690 kPa). The kit must 

be connected to the COLD water line. Do not connect the 

kit to the hot water line.

The Scale Inhibitor System has the following connections:

•  Inlet  

3/4” NPT

•  Outlet 

3/4” NPT

When making a plumbing connection to the System, use a 

back-up wrench on the supporting plumbing. Always use a 

quality, approved pipe sealant or thread seal tape on the pipe 

threads. Be careful not to get the pipe sealant inside the pipe 

when making connections.

DO NOT over tighten the connections. The use of plastic fittings 

when connecting to the plastic head will reduce the possibility of 

cracking the head due to over tightening.

If soldered plumbing is used, do not apply heat to, or near, the 

Head. The use of union (o-ring seal) connections is highly rec-

ommended for ease of installation and future servicing.

CAUTION

This equipment must be installed to comply with the 

basic plumbing code of the Building Officials and Code 

Administrators, Inc. (BOCA) and the Food Service 

Sanitation Manual of the Food and Drug Administration 

(FDA).

CAUTION

Water pressure must not exceed 100 psig. To reduce 

water pressure, install a water pressure regulator and set 

the water pressure to below 100 psig.

Head Bracket

and Screws (8)

Housing

Clear

Head

O-Ring

(incl. with Head)

Scale 

Inhibiter

Element

Filter Wrench

Figure 1. Scale Inhibitor System

ANTUNES  

www.antunes.com  180 Kehoe Blvd., Carol Stream, Illinois  60188

Отзывы: