Protection
For safety, the Dryer Unit equipped with 4 major protective measures
1.
When overheated, the PTC heating unit will grow the resistance so that the power drop. In the meantime,
the fuse will cut the power in order to protect the Dryer and user
’
s safety.
2.
Ultraviolet, especially UVC is harmful to skin and eyes, so the HUMAN SENSING can detect not only
human but also animal. Once they come close to the effective zone, HUMAN SENSING will stop the UVC
Sterilize unit, and indicate light starts to blink. And resume after human/animal left.
3.
The Dryer have time limit in case user forget to close the unit. The LED monitor will show remaining time.
4.
After close the unit or finish the drying program, fan unit will keep running for 20 seconds to cool down
the Dryer.