When the magnetic filter has been dumped and the valve formation of your
power flushing unit returned to re-circulating mode as above (Fig 5) you can
continue to clean the system and repeat the process as required.
Using your diverter valve on your power flushing unit continuously reverse the
flow of water to agitate and loosen the iron oxide. Vibrating techniques on
radiators and pipework will further assist this process.
Please remember to
support the filter
body with your hand
as shown whilst
using the tool to
loosen or tighten
the blue cap.
Excessive force is
not required.
Please note a drain
off valve is fitted to
enable the filter to
be completely
drained after use.
This valve is not
intended for
dumping sludge.