Страница 2: ...engineer in mind the unique design enables the operative to quickly and easily collect and dump sludge without the need to physically remove the dirty sludge by hand utilising the dump function on their power flushing unit Please remove your Flowclean Mag from the packaging and check the contents as follows Flowclean magnet on stand 2 x Isolating valves fitted 1 x Drain valve with cap fitted 1 x C...

Страница 3: ...one design The filter does work in both directions when just in circulating mode When dumping the sludge from your filter please make sure the return water from the heating system is entering the top of the filter and leaving at the bottom Please note that there is a locating lug for the yellow internal cyclone to sit in this must be correctly positioned before you can tighten the big blue nut bac...

Страница 4: ...the top and leave at the bottom Then make sure your power flushing unit valve formation is set correctly to dump then you can slide out the magnet Fig 3 and release the iron oxide straight in to the drain See Fig 1 not back in to the system Once the filter is clear Fig 4 replace magnet and set power flushing valve formation back to recirculate and continue to clean the system Fig1 Fig2 Fig3 Fig4 ...

Страница 5: ...unit continuously reverse the flow of water to agitate and loosen the iron oxide Vibrating techniques on radiators and pipework will further assist this process Please remember to support the filter body with your hand as shown whilst using the tool to loosen or tighten the blue cap Excessive force is not required Please note a drain off valve is fitted to enable the filter to be completely draine...

Страница 6: ...HP AFEH kit 3mtr hose extension kit with straight connector and end caps AFHEA Plate heat exchanger adaptor AFPHA Circulating pump head adaptor Ideal for system boilers AIRG Laser infra red digital thermometer with belt pouch AA15 HDH Liquid probe can be used with AIRG thermometer above ...