Anthem I225 Скачать руководство пользователя страница 3

8. Ventilation

–  Slots  and  openings  in  the  cabinet  are  provided  for  ventilation  and  to  ensure  reliable  operation  of  the

product and to protect it from overheating, and these openings must not be blocked or covered. The openings should
never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should not be placed
in  a  built-in  installation  such  as  a  bookcase  or  rack  unless  proper  ventilation  is  provided  or  the  manufacturer’s
instructions have been adhered to.

9. Power Sources

– This product should be operated only from the type of power source indicated on the marking label.

If you are not sure of the type of power supply to your home, consult your product dealer or local power company. For
products intended to operate from battery power, or other sources, refer to the operating instructions.

10. Grounding and Polarization

– This product may be equipped with a polarized alternating-current line plug (a plug having

one blade wider than the other). This plug will fit into the power outlet only one way. This is a safety feature. If you are
unable  to  insert  the  plug  fully  into  the  outlet,  try  reversing  the  plug.  If  the  plug  should  still  fail  to  fit,  contact  your
electrician to replace your obsolete outlet. Do not defeat the safety purpose of the polarized plug.

11. Power-cord Protection

– Power-supply cords should be routed so that they are not likely to be walked on or pinched

by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the
point where they exit from the product.

12. Outdoor Antenna Grounding – 

If an outside antenna or cable system is connected to the product, be sure the antenna

or cable system is grounded so as to provide some protection against voltage surges and built-up static charges. Article
810 of the National Electrical Code, ANSI/NFPA 70, provides information with regard to the proper grounding of the mast
and  supporting  structure,  grounding  of  the  lead-in  wire  to  an  antenna-discharge  unit,  size  of  grounding  conductors,
location of antenna-discharge unit, connection to grounding electrodes, and requirements for the grounding electrode.

13. Lightning

–  For added protection for this product during a lightning storm, or when it is left unattended and unused for

long  periods  of  time,  unplug  it  from  the  wall  outlet  and  disconnect  the  antenna  or  cable  systems.  This  will  prevent
damage to the product due to lightning and power-line surges.

14. Power Lines – 

An outside antenna system should not be located in the vicinity of overhead power lines or other electric

light or power circuits, or where it can fall into such power lines or circuits. When installing an outside antenna system,
extreme care should be taken to keep from touching such power lines or circuits as contact with them might be fatal.

15. Overloading

– Do not overload wall outlets, extension cords, or integral convenience receptacles as this can result in

a risk of fire or electric shock.

Содержание I225

Страница 1: ...OPERATING MANUAL w w w a n t h e m A V c o m I225...

Страница 2: ...EDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING 1 Read Instructi...

Страница 3: ...kely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs convenience receptacles and the point where they exit from the product 12 Outdoor Ant...

Страница 4: ...and ensure that no objects filled with liquids such as vases are placed on the product 17 Servicing Do not attempt to service this product yourself as opening or removing covers may expose you to dan...

Страница 5: ...beginning of this manual Do not connect power if there are signs of damage to any part of the exterior The front panel power button does not disconnect the product from the AC line Ensure that the pow...

Страница 6: ...ELECTRIQUE NE PAS OUVRIR FUSE T12A 250V AC 120V 60Hz POWER CONSUMPTION 300W TYPICAL CAUTION TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALI...

Страница 7: ...1 INTRODUCTION continued 1 5 REMOTE CONTROL 1 Power off 2 Power on 3 Tone enable bypass 4 Volume 5 Mute 6 Source Rear Battery cover 1 5 2 4 3 6...

Страница 8: ...he red connection on the speaker to the red binding post on the amplifier and the black connection on the speaker to the black binding post on the amplifier using cable that is insulated to handle the...

Страница 9: ...E G R A T E D 2 2 5 DESIGNED AND ENGINEERED BY SONIC FRONTIERS INTERNATIONAL MADE IN TAIWAN AUDIO OUT L R BALANCED INPUT RS 232 CONTROL 12 V TRIGGER IN OUT IN OUT I R RECEIVER PHONO GND PHONO CD AUX 1...

Страница 10: ...pressing one of the following buttons When RECORDER is selected the REC output is disabled since a recorder cannot record itself 3 3 VOLUME CONTROL Front panel Rotate the volume knob clockwise to inc...

Страница 11: ...Treble knobs on the front panel The center position is the default If an adjustment is made you can press TONE on the front panel or remote to quickly turn the adjustment on off without having to ret...

Страница 12: ...ges PREAMPLIFIER Input Resistance 30 k Output Resistance 560 Pre Out 100 Rec Out Rated Input 1 0 Vrms Maximum Input 7 6 Vrms Minimum Load 5 k Rated Output 100 k load 1 0 Vrms Maximum Output 7 6 Vrms H...

Страница 13: ...ROL Infra Red Carrier Frequency 38 kHz Max Emitter Current pass through of input Trigger Input Polarity non polarized Output pass through of input POWER REQUIREMENT Consumption 300 W typical 800 W max...

Страница 14: ...use of the problem and arrange for the appropriate action Alternatively follow the procedure below for factory service A Return Authorization RA number must be obtained from Anthem Technical Support b...

Страница 15: ...ER REC OUT PRE OUT R L L R INPUTS RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR FUSE T12A 250V AC 120V 60Hz POWER CONSUMPTION 300W TYPICAL CAUTION TO PREVENT ELECTRIC SHOC...

Страница 16: ...t e l 1 905 564 1994 M F 9 0 0 a m 5 3 0 p m E T w w w a n t h e m A V c o m 2 0 1 2 0 9 1 3 O M 9 0 1...

Отзывы: