Antelope Isochrone DA Скачать руководство пользователя страница 4

    

  

6

Alternate Sample Rate Selector for Word Clock outputs 7 and 8.

Word clock outputs 7 and 8 are capable of outputting frequencies different from the clock  
received by the DA.  The first five settings select frequencies that are multiples of the 
incoming clock. The final setting, 256 WC, configures the corresponding output to generate  
256 FS Clock (sometimes referred to as Superclock), a protocol used by some Digidesign 
components.  
A red LED is present above each knob.  When lit, it indicates that a valid sample rate is 
selected.  When flashing, the output has been configured to output at a frequency outside 
the supported range (32kHz- 192 kHz).  
For easy reference, the following chart indicates what frequencies outputs 7 and/or 8 
transmit depending on incoming sample rate and knob settings.  Although the DA can 
receive any frequency between 30kHz and 202 kHz, this chart is limited to those most 
commonly used. 

32 kHz

44.1 kHz

48 kHz

88.2 kHz

96 kHz

176.4 kHz

192 kHz

X   

X   

X   

X   

X   

44.1 kHz

48 kHz

WC / 4

X   

X   

X   

88.2 kHz

96 kHz

44.1 kHz

48 kHz

WC /2

32 kHz

44.1 kHz

48 kHz

88.2 kHz

96 kHz

176.4 kHz

192 kHz

WC

X   

X   

88.2 kHz

64  kHz

96 kHz

176.4 kHz

192 kHz

2 WC

X   

X   

X   

X   

X   

X   

X   

X   

176.4 kHz

128 kHz

192 kHz

4 WC

256 fs

256 fs

256 fs

256 WC

ALTERNATE SAMPLE RATE

 

S

A

M

P

L

E

 R

A

T

E

X Output is not valid

Отзывы: