3. INTENDED USE

The ANTELOPE.SUIT is an Over-The-Counter device 
intended to stimulate healthy muscles in order to im-
prove  or  facilitate  muscle  performance.  This  product 
should be used by adults only.

The  ANTELOPE.SUIT  is  not  intended  for  adjunctive 
therapy in the treatment of medical diseases and con-
ditions of any kind. None of the ANTELOPE.SUIT stim-
ulation programs are designed for injured or disease 
afflicted muscles. Its use on such muscles is contraindi-
cated. The stimulation imposed on the muscles by the 
ANTELOPE.SUIT programs is definitely not suitable for 
rehabilitation and physiotherapy. 

The Antelope.Suit may therefore be considered a tech-
nique of muscle training and should only be used for 
this purpose.

4. INTENDED PURPOSE

The ANTELOPE series stimulates the healthy muscles to 
improve performance of human body or general well be-
ing. It is intended to be used by healthy adults.

5. INDICATIONS 

The  ANTELOPE.SUIT  is  intended  to  stimulate  healthy 
muscles in order to improve or facilitate muscle perfor-
mance. It is to be used by adults only.
 
Depending on the parameters of the electrical impuls-
es  (pulse  frequency,  duration  of  contraction,  duration 
of rest, total session duration), different types of muscle 
work can be imposed on the stimulated muscles.
 
Only use the ANTELOPE.SUIT when fully regenerated. 
Follow our workout instructions and also work out with-
out the ANTELOPE.SUIT regularly (at least every fifth ses-
sion).

6. CONTRAINDICATIONS

Powered muscle stimulators should not be used on pa-
tients with cardiac demand pacemakers.

1.   The long-term effects of chronic electrical stimu-

lation are unknown.

2.   Stimulation should not be applied over the neck 

or  mouth.  Severe  spasm  of  the  laryngeal  and 
pharyngeal muscles may occur and the contrac-
tions may be strong enough to close the airway 
or cause difficulty in breathing. 

3.   Stimulation  should  not  be  applied  across  the 

chest in that the introduction of electrical current 
into the heart may cause cardiac arrhythmias.

4. 

Stimulation should not be applied to the head.

5.   Stimulation should not be applied over swollen, 

infected, or inflamed areas or on skin eruptions

6.   Stimulation  should  not  be  applied  over,  or  in 

proximity to, cancerous lesions.

 

PRECAUTIONS:

1.   Safety  of  powered  muscle  stimulators  for  use 

during pregnancy has not been established.

2.   Caution should be used for users with suspected 

or diagnosed heart problems.

3.   Caution should be used for users with suspected 

or diagnosed epilepsy.

4.   Caution should be used in the presence of the fol-

lowing:

a.   When there is a tendency to bleed because of 

injury;

b.   Following recent surgical procedures when 

muscle contraction may disrupt the healing 
process;

c.   Over the menstruating or pregnant uterus; and
d.   Over areas of the skin which lack normal sen-

sation.

5. 

Some patients may experience skin irritation or 
hypersensitivity due to the electrical stimulation 
or the electrodes. 

6.   Electrode  placement  and  stimulation  settings 

should be followed in accordance with this man-
ual

7.   Powered muscle stimulators should be kept out 

of the reach of children.

8.   Powered muscle stimulators should be used only 

with the leads and electrodes recommended for 
use by the manufacturer.

9.   Portable powered muscle stimulators should not 

be  used  while  driving,  operating  machinery,  or 
during  any  activity  in  which  involuntary  muscle 
contractions  may  put  the  user  at  undue  risk  of 
injury.

ADVERSE REACTIONS

Skin irritation and burns beneath the electrodes have 
been reported with the use of powered muscle stimu-
lators.

 !      WARNING

Содержание ANTELOPE.SUIT

Страница 1: ...ANTELOPE SUIT USER MANUAL ...

Страница 2: ...RT 6 9 2 Putting on the ANTELOPE SHORTS 6 9 3 Connecting SUIT and BOOSTER 6 10 The Training Programs 8 10 1 Endurance 8 10 2 Strength 8 10 3 Recovery Massage 8 11 Use of the ANTELOPE BOOSTER 9 11 1 Switch on off 9 11 2 Battery status 9 11 3 Bluetooth Connection 9 11 4 General Functions 9 11 5 Charging the BOOSTER 9 12 FAQs Frequently Asked Questions 10 13 Safety Instructions 11 14 Care and Mainten...

Страница 3: ...d equipment damage Indicates a hazard with a high level of risk which if not avoided will result in death or serious injury Helpful information to aid in the particular area or function being de scribed The ANTELOPE system consists of ANTELOPE SUIT Two textiles with integrated electrodes that connect with the BOOSTER via internal external cable ANTELOPE 8C BOOSTER BOOSTER provides the electrodes w...

Страница 4: ...r the neck or mouth Severe spasm of the laryngeal and pharyngeal muscles may occur and the contrac tions may be strong enough to close the airway or cause difficulty in breathing 3 Stimulation should not be applied across the chest in that the introduction of electrical current into the heart may cause cardiac arrhythmias 4 Stimulation should not be applied to the head 5 Stimulation should not be ...

Страница 5: ...he partial loss of strength delayed muscle soreness and a significant increase of muscle protein levels e g cre atine kinase levels found in the blood Especially after the first intense training sessions with the ANTELOPE SUIT there is a heightened risk of muscular damage These problems shall not occur if you closely follow our workout instructions The following points may indicate serious damage ...

Страница 6: ...OOSTER The ANTELOPE 8C BOOSTER is the energy source of the system and connects with the ANTELOPE SUIT via an baseplate on the side of the shirt It triggers the elec trical impulses which enhance the natural muscle con traction To control the whole system in a convenient way the BOOSTER is connected to the ANTELOPE APP via Bluetooth With this APP you can choose a suitable stimulation program before...

Страница 7: ...lds or wrinkles 3 Close the zippers NOTE The electrodes must be placed directly onto the skin Excessive hair growth or extremely dry skin can affect the stimulation Ensure that the electrodes are placed directly on the targeted muscle 9 2 Putting on the ANTELOPE SHORTS 1 Put on the SHORTS and make sure that the electrodes lie flat on your skin without folds or wrinkles NOTE The electrodes must be ...

Страница 8: ...pe titions during each impulse Examples Push ups squats planks dips etc Suggested training time 10 minutes for the first 3 training sessions After that you can increase the training time each time you work out by 5 minutes until you reach a total of 20 minutes This training should NOT be used for longer than 20 minutes Cool Down relaxed jogging or walking without any stimulation 5 10 minutes follo...

Страница 9: ... two minutes 11 4 General Functions The impulse intensity is adjustable by pressing the button on the BOOSTER itself By pressing you increase the intensity of all channels by one unit By pressing you decrease the intensity of all channels by one unit 11 5 Charging the BOOSTER The 8C BOOSTER is equipped with a rechargeable lith ium ion battery While it takes about approximately one hour to fully ch...

Страница 10: ...a couple of minutes after you take off the product Another reason might be pressure marks caused by the compression This is nothing to worry about However you should not wear the SUIT for several hours Severe irritation might derive from too high stimulation intensity The next time you use the ANTELOPE SUIT try to start at a lower level and slowly increase the intensity Extreme redness might be ca...

Страница 11: ...ving 14 CARE AND MAINTENANCE 14 1 Battery Life Store your BOOSTER in a cool dry place In case you do not intend to use the BOOSTER for a longer period of time please make sure to charge it at least every six months You must not try to replace the battery pack yourself Opening the BOOSTER yourself may cause damage and leads to expiry of your guar antee 14 2 Washing instructions The textile consists...

Страница 12: ... any questions regarding your guarantee 17 PACKAGING The following symbols are printed on the package or the user manual colour and size may vary By displaying the CE mark the manufacturer confirms that the product complies with all necessary requirements of the EU regulations Confor mity assessment procedures have been completed Manufacturer Details Date of Production Serial Number Store in a dry...

Страница 13: ... This product should be used by adults only The ANTELOPE SUIT is not intended for adjunctive therapy in the treatment of medical diseases and con ditions of any kind None of the ANTELOPE SUIT stim ulation programs are designed for injured or disease afflicted muscles Its use on such muscles is contraindi cated The stimulation imposed on the muscles by the ANTELOPE SUIT programs is definitely not s...

Отзывы: