Operating Manual ECD3AM-00-00 

Page 1 of 13 

(07/16)   R0117AGB 

 

Operating Manual 

 

Retrofit Speed-Controller Type  

ECD3AM-00-00 

 

Replacement for  

 

ECdrive Type D400B001, Ziehl-Abegg 

 

 

Содержание ECD3AM-00-00

Страница 1: ...Operating Manual ECD3AM 00 00 Page 1 of 13 07 16 R0117AGB Operating Manual Retrofit Speed Controller Type ECD3AM 00 00 Replacement for ECdrive Type D400B001 Ziehl Abegg...

Страница 2: ...LECTRICAL INSTALLATION 6 3 3 INFORMATION ON EMC 7 3 4 ELECTRICAL CONNECTION CONTROLLER 8 3 5 OPERATING AND DISPLAY ELEMENTS 9 3 6 ADJUSTMENT 9 3 7 ADJUSTMENTS INTERNAL 10 3 8 CODING JUMPERS INTERNALLY...

Страница 3: ...thoroughly Ensure that the voltage is less than 60V before touching electrical contacts The user must use independent monitoring units in order to ensure that a malfunctioning drive is stopped safely...

Страница 4: ...0 90 UZK Max output current IMmax 6 5 A Phase Continuous output current IM 3 A Phase Rated output power 1 SN 0 9 kVA Efficiency ca 95 Power loss idling2 PV0 ca 18 W Power loss full load PV ca 50 W Ma...

Страница 5: ...Operating Manual ECD3AM 00 00 Page 5 of 13 07 16 R0117AGB 2 2 Dimensions...

Страница 6: ...tricity The discharging can be achieved by touching a grounded metal surface beforehand Due to the leakage currents of the controller 3 5 mA via the protective conductor PE must be in accordance with...

Страница 7: ...nes are to be laid two way source and target large area and well conducting to a ground1 In case of poor potential equalization between shielded connections an additional balancing network of at least...

Страница 8: ...nes Motor 1 RLG U 2 RLG V 3 RLG W 4 Encoder active High n c 5 Encoder active Low 6 Supply voltage 7 Supply voltage 8 Shield X8 Connectors for signal lines 1 15 V 2 0 V 3 Com Opt out 4 Ready 5 Stand st...

Страница 9: ...N Controller ready OFF Controller collective fault Intermediate circuit 450 V Intermediate circuit 150 V Heat sink temperature 80 C If there is a fault the output stage is disabled immediately The fau...

Страница 10: ...the engine at standstill n n max Sollwert 10V 0V I max Internal factory setting may not be changed tH Ramp up time of the set point integrator tR Return time of the set point integrator Setting the s...

Страница 11: ...SET n max PI tH tR STB1 Jumper position a Brake A cut off of the control voltage on connecting terminal 2 5 and or X2 6 causes the motor to come to a standstill This is the normal operation mode of th...

Страница 12: ...STB1 S1 L2 UZK Rotation direction logic Set point intergator Drehzahlregelung monitoring heatsink temperature UZK switching power internal voltage supply counter clockwise clockwise Output stage enge...

Страница 13: ...hnical documentation the measures are described with which the drive regulator complies with the EMC limiting values The electromagnetic compatibility of the machine is based on the method and thoroug...

Отзывы: