Danger of Burns

This device is for adult use only and must be installed out of the reach of children. Never

leave the unit running unattended.

Never aim the output nozzle directly at people.

Fog machine output is very hot. Avoid coming within 60 cm of the output nozzle during

operation.

Locate the fog machine in a well-ventilated area. Never cover the unit’s vents. In order to

guarantee adequate ventilation, allow a free air space of at least 20 cm around the sides

and top of the unit.

Never aim the output nozzle at flames.

If the supply cord is damaged, it must be replaced by manufacturer or its service agent or

qualified personnel in order to avoid a hazard.

Always let your ANTARI Fog Machine cool down before cleaning or service.

Danger of Explosion

Never add flammable liquids (such as oil, gas, perfume) to the fog liquid tank.

Use only high-quality, water-based fog liquid that your dealer recommends. Other fog

liquids may cause clogging or damage fog machine.

Always make sure there is sufficient liquid in the tank. Operating this unit without liquid

will cause damage to the pump as well as over-heating of the heater.

If your ANTARI fog machine fails to work properly, discontinue use immediately.    Drain

all fog liquid from the tank, pack the unit securely (preferably in the original packing

material), and return it to your ANTARI dealer for service.

Always empty fluid tank before posting or transporting this unit.

Never drink fog liquid. If it is ingested, call a doctor immediately. If fog liquid comes in

contact with skin or eyes, rinse thoroughly with water.

Note:

Pay  attention  to  all  warning  labels  and instructions  printed  on  the  exterior  of  your

ANTARI Fog Machine

Unpacking & Inspection

Open the shipping carton and verify that all equipment necessary to operate the system has

arrived intact.

The shipping carton should contain the following items:

Содержание WiFi-800

Страница 1: ...1 WiFi 800 USER MANUAL 2013 Antari Lighting and Effects Ltd English...

Страница 2: ...2...

Страница 3: ...pliance from the electric supply before refilling liquid cleaning or performing maintenance on the machine Danger of Electric Shock Household Use only Not designed for outdoor use Use grounded electri...

Страница 4: ...ank Use only high quality water based fog liquid that your dealer recommends Other fog liquids may cause clogging or damage fog machine Always make sure there is sufficient liquid in the tank Operatin...

Страница 5: ...approved fluid Step 3 Connect the machine to suitable rated power supply To determine the power requirement for the machine refer to the label on the back of the machine Step 4 Turn on the machine and...

Страница 6: ...Settings Wi Fi list of available Wi Fi device will be showed Step 2 Select WIFI800 XXXXXXXX XXXXXXXX indicate the serial number of the machine is also the default SSID and password Step 3 Enter passwo...

Страница 7: ...tion time Slide the time bar from 1 to 60 seconds press ON to start making smoke Smoke will stop once the timer count down to zero Continuous Mode simply press the ON button to make smoke The machine...

Страница 8: ...nfiguration allows you to make customize configuration to your Wi Fi setting To start configuration first make Wi Fi connection with the machine then open a web browser enter http 192 168 16 254 and w...

Страница 9: ...s settings Basic Radio On Off Turn radio signal on or off On default Off WiFi On Off Turn WiFi signal on or off On default Off Network Mode Select one of the following that meets your clients 11b g mi...

Страница 10: ...the SSID of the machine will not be seen The wireless client will have to know the SSID in order to connect to it AP Isolation Preventing devices connected to AP from communicating directly with each...

Страница 11: ...etup password Key Renewal interval Enter the amount of time before the group key used for broadcast and multicast data is changed 3600 is default Administration Management Account Change login account...

Страница 12: ...12...

Страница 13: ...fog machine warm up and re heating cycles approx 1 2 minutes and stays ON when the machine becomes operational The Z 10 features the toggle switch function press once for continuous ON press again to...

Страница 14: ...quid to become contaminated Always replace the caps on the fog liquid container and the fog machine liquid tank immediately after filling After every 40 hours of operation it is recommended to use dis...

Страница 15: ...izes However a properly maintained fog machine should provide longer and more reliable life time Storage 1 When machine is not in use store it in a cool and dry place 2 It is strongly recommended to t...

Страница 16: ...16 Antari WiFi800 Antari Antari Antari Antari...

Страница 17: ...17 50CM 20CM 200 50CM Antari FLR FLG Antari Antari 1...

Страница 18: ...18 2 3 Antari 1 50 2 Antari 3 4 LED 2 5 6 OFF App Store Antari Fog 800 iPhone iPad WiFi 800 iPhone iPad Wifi 800 1 iPhone iPad Wi Fi Wi Fi 2 WiFi800 XXXXXXXX XXXXXXXX SSID...

Страница 19: ...19 3 Fog 800 WiFi 800...

Страница 20: ...20 1 60 ON 0 ON OFF ON Wi Fi Wi Fi http 192 168 16 254 admin admin...

Страница 21: ...21...

Страница 22: ...22 ON OFF On Off WiFi WiFi ON OFF On Off 11b g mixed mode 11b only 11g only 11b g n mixed mode 11n only 2 4G 32 SSID...

Страница 23: ...23 Disable OPENWEP WPA PSK WPA2 PSK WPAPSKWPA2PSK WPA TKIP AES TKIPAES 3600...

Страница 24: ...24 admin admin...

Страница 25: ...25 4 12 LED WiFi800 WiFi 8 9 WiFi800 Z 10 On Off 10M 6 3mm 45 60 Z 40 10M 6 3mm Power 10 250 Intervl Duration 10 120 Fog 100 Z 50 6 3mm 50M...

Страница 26: ...26 1 2 3 Antari 40 1 2 3 4...

Страница 27: ...27 WiFi 800 WiFi 800 AC100 120V AC 220 240V 50HZ 60HZ 800W 3 000cu ft min 0 8 Liter 60 Min 0 8 Liter 4 1 Kg mm L315 W128 H220 Z 10 ON OFF Z 40 Z 50 1 7 min...

Страница 28: ...28 C08WF8001...

Отзывы: