7
Fuse Replacement
Disconnect AC power before replacing fuse. Only replace fuse with same type
and rating.
Step 1: Disconnect power cord from supply.
Step 2: Use a flat-head screwdriver to release fuse holder.
Step 3: Replace fuse with exact same type and rating as indicated below.
Step 4: Reinsert fuse holder.
Fuse
120V = T0.8A 250V
230V = T0.8A 250V
Technical Specifications
- Input voltage
- Rated power
- Compatible fluid
- Ambient temp. range
- Control
- Connection
- Dimension
- Weight
US model : AC 100-120V, 50 / 60Hz 0.35A
EU model : AC 220-240V, 50 / 60Hz 0.18A
48W
Antari Fluid
5 °C - 40 °C (41 °F-104 °F)
Auto
IEC (Power)
XLR 3-pin (Data)
Supply unit L179 W167 H84 mm
(L7.05 W6.57 H3.31 inch)
Tank unit L158 W103 H248 mm
(L6.22 W4.06 H9.76 inch)
Supply unit 1.95 kg (4.30 lbs)
Tank unit 1.8 kg (3.97 lbs)