fog volume and fan volume. Whatever channel you select on
the unit, the channel next to it will be selected automatically
for fan volume control. Each channel has a value range of 0
to 225. Timer functions such as duration and interval can be
programmed using the DMX controller or the DMX control
software being used by lighting and effects operator.
If Channel has a value from 0 to 5, the unit is OFF.
Between the values 6 to 249 the volume of fog output is
regulated. With 6 being the minimum volume of fog
produced and 249 approaching the maximum. The volume
output rises as the DMX value is increased.
If Channel has a value from 250 TO 255, the machine will
operate at maximum output.
Note: In the example above, if the machine were assigned the
DMX address of 124, Channel would correspond to DMX
address 124.
In general, ANTARI X Fogger with X-20II DMX Module
conform to the following performance specifications:
0
1.Average Operating temperature = 250 C
2.X Fogger can maintain maximum output for 60 seconds or
more
Maintenance
Do not allow the fog liquid to become contaminated. Always
replace the caps on the fog liquid container and the fog
machine liquid tank immediately after filling.
After every 40 hours of continuous operation, it is
recommended to run a cleaning solution composed of 80%
distilled water and 20% white vinegar through the system to
prevent the accumulation of particulate matter in the heating
Note: All fog machines are prone to clogging due to the thick
consistency of fog fluid and the high temperature at which it
vaporizes. However, a properly maintained fog machine
should provide years of reliable use.
Clean with a dry cloth only. Store dry.
element. The recommended cleaning regimen is as follows:
1.Empty all fog fluid from machine. Add cleaning solution to
tank. Plug unit in and begin warm up.
2.Run unit in a well-ventilated area until tank is empty.
3.Cleaning is now complete. Refill with fog liquid.